Display the driver log for the specified hardware component.

Syntax
show logging driverlog stack-unit stack-unit-number
Parameters
stack-unit stack-unit-number
Enter the keywords stack-unit followed by the stack member ID of the switch for which you want to display the driver log.
defaults
none
Command Modes
  • EXEC
  • EXEC Privilege
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.10(0.1)
Introduced on the S6010-ON and S4048T-ON.
9.10(0.0)
Introduced on the S3148.
9.10(0.0)
Introduced on the S6100–ON.
9.8(2.0)
Introduced on the S3100 series.
9.8(1.0)
Introduced on the Z9100–ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Introduced on the S6000-ON.
9.2(1.0)
Introduced on the Z9500.
9.2(0.0)
Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
Example
DellEMC#show logging driverlog stack-unit 1

0:Task(tUsrRoot): [   491677]PSU FanCtrl Drv ERR: ssnDrvPoePsuEepromWriteEnable : 66 - Psu 1 is Not Present Cannot enable
1:Task(tUsrRoot): [      338]PSU FanCtrl Drv ERR: ssnDrvPsuFanCtrlInit : 118 - Cannot enable psu -127228353
2:Task(tUsrRoot): [     6876]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Main block failed checksum calulated checksum 0x1d actual chksum 0x0
3:Task(tUsrRoot): [       61]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Main block failed errcode 6
4:Task(tUsrRoot): [       89]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Redundant block failed checksum calulated checksum 0xc9a6 actual chksum                   0x0
5:Task(tUsrRoot): [       57]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Redundant block failed errcode 6
6:Task(tUsrRoot): [       51]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom, failed to get any good block
7:Task(tUsrRoot): [       75]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Main block failed checksum calulated checksum 0x1d actual chksum 0x0
8:Task(tUsrRoot): [       55]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Main block failed errcode 6
9:Task(tUsrRoot): [       62]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Redundant block failed checksum calulated checksum 0xc9a6 actual chksum                   0x0
10:Task(tUsrRoot): [       55]EEPROM LIB ERR: f10EepromBlkRead@psu0eeprom: Redundant block failed errcode 6
Usage Information
This command displays internal software driver information, which may be useful during troubleshooting switch initialization errors, such as a downed Port-Pipe.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\