timers throttle lsa all

Configure LSA transmit intervals.

Syntax
timers throttle lsa all {start-interval | hold-interval | max-interval}

To return to the default, use the no timers throttle lsa command.

Parameters
start-interval
Set the minimum interval between initial sending and resending the same LSA. The range is from 0 to 600,000 milliseconds.
hold-interval
Set the next interval to send the same LSA. This interval is the time between sending the same LSA after the start-interval has been attempted. The range is from 1 to 600,000 milliseconds.
max-interval
Set the maximum amount of time the system waits before sending the LSA. The range is from 1 to 600,000 milliseconds.
Defaults
  • start-interval: 0 msec
  • hold-interval: 5000 msec
  • max-interval: 5000 msec
Command Modes
ROUTER OSPF
Command History

This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking OS Command Line Reference Guide.

Version
Description
9.10(0.1)
Introduced on the S6010-ON and S4048T-ON.
9.10(0.0)
Introduced on the S3148.
9.10(0.0)
Introduced on the S6100-ON.
9.8(2.0)
Introduced on the S3100 series.
9.8(1.0)
Introduced on the Z9100-ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Introduced on the S6000-ON.
9.2(1.0)
Introduced on the Z9500.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
9.0.2.0
Introduced on the S6000..
8.3.11.1
Introduced on the Z9000.
8.3.8.0
Introduced on the S4810.
Usage Information
LSAs are sent after the start-interval and then after hold-interval until the maximum interval is reached. In throttling, exponential backoff is used when sending same LSA, so that the interval is multiplied until the maximum time is reached. For example, if the start-interval 5000 and hold-interval 1000 and max-interval 100,000, the LSA is sent at 5000 msec, then 1000 msec, then 2000 msec, them 4000 until 100,000 msec is reached.