S4048-ON Installation Guide January 2019

PDF

Chassis physical design

Table 1. Chassis physical design . Table listing the chassis physical design.
Parameter Specifications
Height 1.71 inches (43.5 mm)
Width 17.09 inches (434 mm)
Depth 18.11 inches (460 mm)
Chassis weight with factory-installed components 21.7 lbs (9.86 kg)
Rack clearance required

Front: 5 inches (12.7 cm)

Rear: 5 inches (12.7 cm)

Table 2. Environmental parameters . Table listing environmental parameters.
Parameter Specifications
Operating temperature 32° to 113°F (0° to 45°C)
Operating humidity 5 to 85% (RH), non-condensing
Storage temperature –40° to 158°F (–40° to 70°C)
Storage humidity 5 to 95%, non-condensing
Maximum thermal output 1153.265 BTU/hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters)
Shock Meets Bellcore Zone 4 earthquake requirements (MIL-STD-810)
Table 3. AC power requirements. Table listing the AC power requirements.
Parameter Specifications
Power supply 100–240 VAC 50/60 Hz
Maximum current draw per system

5.8 A @ 398.02 watts/100vac

2.9 A @ 398.02 watts/200vac

Maximum power consumption 460 Watts
Typical power consumption 338 Watts
Reliability MTBF 355.178 hours