Dell EMC SmartFabric OS10 User Guide Release 10.5.0

Custom TLVs

iDRAC organizationally specific TLVs

Table 1. iDRAC organizationally specific TLVs; Subtypes used in iDRAC custom TLVs (Type – 127, OUI – 0xF8-0xB1-0x56)iDRAC organizationally specific TLVs; Subtypes used in iDRAC custom TLVs (Type – 127, OUI – 0xF8-0xB1-0x56)
TLV Subtype Description
Originator 1 Indicates the iDRAC string that is used as the originator. This string enables external switches to identify iDRAC LLDPDUs.
Port type 2 Following are the applicable port types:
  1. iDRAC port (dedicated)
  2. NIC port
  3. iDRAC and NIC port (shared)
Port FQDD 3 Port number that uniquely identifies a NIC port within a server.
Server service tag 4 Service tag ID of the server.
Server model name 5 Model name of the server. For example, PowerEdge FC640.
Server slot number 6 Slot number of the server. For example, 1, 2, 3, 1a, and 1b.
Chassis service tag 7 Service tag ID of the chassis. (Applicable only to blade servers.)
Chassis model 8 Model name of the chassis. (Applicable only to blade servers.)
IOM service tag 9 Service tag ID of the IOM device. (Applicable only to blade servers.)
IOM model name 10 Model name of the IOM device. (Applicable only to blade servers.)
IOM slot label 11 Slot label of the IOM device. For example, A1, B1, A2, and B2 (applicable only to blade servers).
IOM port number 12 Port number of the NIC. For example, 1, 2, and 3.

Isilon organizationally-specific TLVs

Table 2. Isilon-related TLVs (Type – 127, OUI – 0xF8-0xB1-0x56)Isilon-related TLVs (Type – 127, OUI – 0xF8-0xB1-0x56)
TLV Subtype Description
Subtypes used in LLDP custom TLVs that are transacted by the Isilon nodes
Originator 1 Indicates the Isilon string that is used as the originator. This string enables the OS10 switches to identify the Isilon originated LLDPDUs.
RA prefix 2 Indicates the IPV6 address prefix for SLAAC. Isilon nodes uses this prefix to communicate with the master and the OS10 switch to compute the Virtual IP address for the specific fabric instance. The RA prefix is different for each fabric.
Fabric ID 3 Indicates the ID of the fabric the LLDPDU is originating from.

Isilon-related TLVs – Subtypes used in LLDP custom TLVs that are transacted by the OS10 switches

Originator 1 Indicates the OS10 string that is used as the originator. The string enables the OS10 switches to identify LLDPDUs.
Role 2 Following are the applicable roles:
  1. LEAF
  2. SPINE
  3. UNKNOWN
IP address 3 Indicates the IPv6 address of the originator.
Virtual IP address of the fabric 4 Virtual IP address of the master node. The Isilon nodes can also use this IPv6 address when needed.
MAC address of the physical interface 5 MAC address used by the OS10 switches for ND.