errdisable recovery interval

Configures recovery interval timer to delay the recovery of ports when there is a BPDU Guard violation.

Syntax
errdisable recovery interval interval-value
Parameters
interval-value—Enter the time interval in seconds. The range is from 30 to 65535.
Default
300 seconds
Command Mode
CONFIGURATION
Usage Information

This command applies only to STP-enabled ports. The command takes effect only when the BPDU guard is configured on a port. The recovery timer value is applicable only for shutdown case. For blocking case, the default value of 300 seconds is used.

The recovery timer starts whenever there is a BPDU guard violation.

The no version of the command resets the timer to the default value.

Example
OS10(config)# errdisable recovery interval 45