Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC SmartFabric OS10 User Guide Release 10.5.0

PDF

show vlt mac-inconsistency

显示在跨多个 VLAN VLT 对等方之间学习的动态 MAC 地址的不一致。

语法
show vlt mac-inconsistency
参数
默认
未配置
命令模式
EXEC
使用情况信息

使用此命令可以检查 VLT 对等节点之间的 MAC 地址表条目是否存在不匹配。仅当您观察到网络融合问题时,才能使用此命令。要验证对等交换机上的 VLT 配置不匹配问题,请使用 show vlt domain-name mismatch command

如果存在流量融合问题,请使用此命令。

示例
OS10# show vlt-mac-inconsistency
Checking Vlan 228 .. Found 7 inconsistencies .. Progress 100%
VLAN 128
----------
MAC 00:00:00:00:00:02 is missing from Node(s) 2
VLAN 1
----------
MAC 00:a0:c9:00:00:18 is missing from Node(s) 2
MAC 00:a0:c9:00:00:20 is missing from Node(s) 2
VLAN 131
----------
MAC 00:00:00:00:00:02 is missing from Node(s) 2
VLAN 132
----------
MAC 00:00:00:00:00:02 is missing from Node(s) 2
VLAN 135
----------
MAC 00:00:00:00:00:02 is missing from Node(s) 2
VLAN 137
----------
MAC 00:00:00:00:00:02 is missing from Node(s) 2

Run "show vlt mismatch ..." commands to identify configuration issues
支持的版本
10.2.0E or later

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\