Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC SmartFabric OS10 User Guide Release 10.5.1

PDF

Assign interfaces to be managed by the controller

In a VTEP, explicitly assign interfaces for an OVSDB controller to manage.

Before you assign the interface, consider the following:

  • The interface must be in Switchport Trunk mode.
  • The interface must not be a member of any VLAN
  • The interface must not be a member of a port-channel

When the above conditions are not met when assigning the interfaces to be managed by the controller, the system returns error messages.

When the interface is assigned, you cannot:

  • remove the interface from Switchport Trunk mode
  • add the interface as a member of any VLAN
  • remove the interface from the controller configuration if the interface has active port-scoped VLAN (Port,VLAN) pairs configured by the controller

To assign an interface to be managed by the OVSDB controller:

  1. Configure an interface from CONFIGURATION mode.
    OS10(config)# interface ethernet 1/1/1
  2. Configure L2 trunking in INTERFACE mode.
    OS10(config-if-eth1/1/1)# switchport mode trunk
  3. Configure the access VLAN assigned to a L2 trunk port in the INTERFACE mode.
    OS10(config-if-eth1/1/1)# no switchport access vlan
  4. Assign the interface to the controller.
    OS10(config-if-eth1/1/1)# nve-controller

To view the controller information and the ports the controller manages, use the show nve controller command.

OS10# show nve controller

Management IP            : 10.16.140.29/16
Gateway IP               : 55.55.5.5
Max Backoff              : 1000
Configured Controller    : 10.16.140.172:6640 ssl (connected)

Controller Cluster
IP                 Port     Protocol      Connected   State         Max-Backoff
10.16.140.173      6640     ssl           true        ACTIVE        1000
10.16.140.171      6640     ssl           false       BACKOFF       1000
10.16.140.172      6640     ssl           true        ACTIVE        1000


NVE Controller Ports
ethernet1/1/1:1
ethernet1/1/15

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\