Dell iDRAC Service Module 5.3.0.0 User’s Guide
Install iDRAC Service Module
The iDRAC Service Module (iSM) can be installed on any of the following operating systems:
- Microsoft Windows
- Linux
- VMware ESXi
For the list of operating systems that are supported on iSM, see Supported operating systems.
To check the iSM running status on Microsoft Windows operating systems, run the following command:
<iSM install path>/shared/bin/dcismcfg.exe --getismstatus/-g
To check the iSM running status on Linux and VMware ESXi 7.x operating systems, run the following command:
<iSM install path>/bin/dcismcfg --getismstatus/-g
To check the iSM running status on the VMware ESXi 8.0 operating system, run the following command:
esxcli dell ism config --getismstatus/-g
NOTE:The default USB NIC IP address set by iSM from iSM version 4.x.x.x is 169.254.1.1. The USB NIC IPv6 address that is used in iSM is fe80::1234 and this address is not reconfigurable in iDRAC.
NOTE:During the installation of iSM, the OS to iDRAC Pass-through channel is enabled in USB NIC mode. Use any of the iDRAC interfaces to modify the OS to iDRAC Pass-through configuration. However, if the
OS to iDRAC Pass-through state is set to
Disabled, then the iSM features that depend on the USB NIC will not be functional.