Dell iDRAC Service Module 5.3.0.0 User’s Guide
Operating system supported feature matrix
The table lists the iDRAC Service Module 5.3.0.0 features, supported operating systems, and supported Dell PowerEdge 14G, PowerEdge 15G, and PowerEdge 16G servers.
| Features | Servers | Operating systems | ||
|---|---|---|---|---|
| - | Supported PowerEdge series | Microsoft Windows (including Hyper-V systems) | Linux | Virtualization (VMware ESXi) |
| Sharing operating system information | 14G, 15G, 16G | Yes | Yes | Yes |
| Lifecycle Controller Log replication | 14G, 15G, 16G | Yes | Yes | Yes |
| Automatic system recovery/watchdog | 14G, 15G, 16G | Yes | Yes | Yes |
| Windows Management Instrumentation Providers | 14G, 15G, 16G | Yes | N/A | N/A |
| Prepare to remove NVMe device through iDRAC | 14G, 15G, 16G | Yes | Yes | Yes |
| SupportAssist collection from host operating system | 14G, 15G, 16G | Yes | Yes | Yes |
| Operating system and application data | 14G, 15G, 16G | Yes | Yes | Yes |
| Remote iDRAC hard reset | 14G, 15G, 16G | Yes | Yes | Yes |
| iDRAC access using Host OS | 14G, 15G, 16G | Yes | Yes | N/A |
| In-Band support for iDRAC SNMP alerts | 14G, 15G, 16G | Yes | Yes | Yes |
| Network interface monitoring support through Redfish client | 14G, 15G, 16G | Yes | Yes | Yes |
| Enable WS-Man remotely | 14G, 15G, 16G | Yes | N/A | N/A |
| FullPowerCycle | 14G, 15G, 16G | Yes | Yes | Yes |
| In-Band SNMP get | 14G, 15G, 16G | Yes | Yes | N/A |
| Live VIB installation | 14G, 15G, 16G | N/A | N/A | Yes |
| SupportAssist-anonymous collection report | 14G, 15G, 16G | Yes | Yes | Yes |
| iDRAC UI launcher | 14G, 15G, 16G | Yes | Yes | N/A |
| IPv6 support | 14G, 15G, 16G | Yes | Yes | N/A |
| Auto dispatch for selective events | 14G, 15G, 16G | Yes | Yes | Yes |
| SupportAssist collection with selective PII | 14G, 15G, 16G | Yes | Yes | Yes |
| Single Sign-on (SSO) | 14G, 15G, 16G | Yes | Yes | N/A |
| Autoupdate iSM installation | 14G 15G, 16G | Yes | Yes | N/A |
| Server storage(S2D) correlation | 14G, 15G, 16G | Yes | N/A | N/A |
| S.M.A.R.T monitoring in AHCI Mode | 14G, 15G, 16G | Yes | Yes | Yes |
| S.M.A.R.T monitoring in software RAID mode | 14G, 15G, 16G | Yes | N/A | N/A |
| OMSA SNMP alerts mapping | 14G, 15G, 16G | Yes | Yes | Yes |
| Software RAID | 14G, 15G, 16G | Yes | N/A | N/A |
| Software RAID to assign or unassign dedicated or global hot spare | 14G, 15G, 16G | Yes | No | No |
| Isolation of OS to iDRAC Pass-through Independent feature | 14G, 15G, 16G | Yes | Yes | Yes |
| Containerization of iSM | 14G, 15G, 16G | No | Yes | No |
| Metric Injection (Host OS Telemetry) | 14G, 15G, 16G | Yes | Yes | Yes (only on VMware ESXi 8.0 U2) |
N/A - Not applicable