PowerEdge Servers Error and Event Messages Reference Guide
ACC—Accelerator Event Messages
ACC0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Graphic Processing Unit (GPU) baseboard has saved log data related to critical events.
- Detailed Description
- The Graphic Processing Unit (GPU) baseboard has saved log data related to critical events.
- Recommended Response Action
- Collect the Technical Support Report (TSR) log data. To obtain more information about the GPU baseboard critical events, select the GPU Debug option. All the critical events are bundled as a part of the TSR log data.
- Category
- System Health (ACC = Accelerator)
- Severity
- Critical
- Trap/EventID
- 3761
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
ACC0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Graphics Processing Unit (GPU) Baseboard has detected arg1 GPUs that are incorrectly located. The GPUs located in slots arg2 must be relocated.
- Arguments
- arg1 = Number
- arg2 = Slot_Indexes
- Detailed Description
- The Graphics Processing Unit (GPU) Baseboard has detected GPUs that are incorrectly located as identified in the message. The GPUs located in slots as identified in the message must be relocated.
- Recommended Response Action
- To relocate the GPUs to the compatible slots. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (ACC = Accelerator)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
ACC0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- iDRAC has successfully configured arg1 SerDes retimers that operate in arg2.
- Arguments
- arg1 = Number
- arg2 = Mode
- Detailed Description
- iDRAC has successfully configured the SerDes retimers on the GPU baseboard that operate in the mode identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (ACC = Accelerator)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
ACC0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to configure the SerDes retimer because iDRAC is unable to communicate with the device.
- Detailed Description
- iDRAC is unable to communicate with the SerDes retimer on the GPU baseboard and unable to set the configuration mode.
- Recommended Response Action
- Perform a server Cold Reboot operation in the iDRAC UI by clicking Configuration > Power Management > Power Control > Power Cycle System (cold boot). Or, run the following RACADM command at the CLI: racadm serveraction powercycle. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (ACC = Accelerator)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
ACC0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to detect arg1 OSFP cards that are required for correct operation.
- Arguments
- arg1 = number
- Detailed Description
- OSFP cards cannot be detected. These are required for correct operation. The system functionality may be degraded.
- Recommended Response Action
- Contact your service provider.
- Category
- Configuration (ACC = Accelerator)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
ACC0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to power on system because the GPU baseboard is not ready: arg1.
- Arguments
- arg1 = reason
- Detailed Description
- The host system is not powered on since GPU Baseboard is not ready.
- Recommended Response Action
- Perform a manual AC cycle. If the issue still persists, generate two SupportAssist Collections (TSRs), one with the debug logs enabled and one with GPU logs enabled. These options are mutually exclusive. Visithttps://www.dell.com/support/incidents-online/contactus/dynamicto use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (ACC = Accelerator)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*