PowerEdge Servers Error and Event Messages Reference Guide

PDF

AMP—Amperage Event Messages

AMP0300

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0301

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System board <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0302

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
LCD Message
The system board <name> current is outside of range.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0303

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System board <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0304

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is outside of range.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System board <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0305

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 current is within range.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (AMP = Amperage)
Severity
Informational
Trap/EventID
2179
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0306

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0307

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
Disk drive bay <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0308

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0309

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
Disk drive bay <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0310

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is outside of range.
Arguments
  • arg1 = name
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
Disk drive bay <name> current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0311

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Disk drive bay arg1 current is within range.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (AMP = Amperage)
Severity
Informational
Trap/EventID
2179
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0312

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is less than the lower warning threshold.
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

AMP0313

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is less than the lower critical threshold.
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System level current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

AMP0314

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is greater than the upper warning threshold.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

AMP0315

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is greater than the upper critical threshold.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System level current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

AMP0316

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is outside of range.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
LCD Message
System level current is outside of range. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

AMP0317

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System level current is within range.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (AMP = Amperage)
Severity
Informational
Trap/EventID
2179
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

AMP0318

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is less than the lower warning threshold.
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0319

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is less than the lower critical threshold.
Detailed Description
No detailed description available.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0320

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is greater than the upper warning threshold.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Warning
Trap/EventID
2178
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0321

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is greater than the upper critical threshold.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0322

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is outside of range.
Detailed Description
Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes.
Category
System Health (AMP = Amperage)
Severity
Critical
Trap/EventID
2177
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP0323

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis power level current is within range.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (AMP = Amperage)
Severity
Informational
Trap/EventID
2179
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

AMP400

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor has failed, and the last recorded value by the sensor was arg2 A.
Arguments
  • arg1 = sensor name
  • arg2 = current
Detailed Description
The current sensor identified in the message has failed. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category
System Health (AMP = Amperage)
Severity
Critical
OMSA Event ID
5200
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

AMP401

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the arg1 sensor value.
Arguments
  • arg1 = sensor name
Detailed Description
The current sensor identified in the message has failed. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category
System Health (AMP = Amperage)
Severity
Warning
OMSA Event ID
5201
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

AMP402

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor returned to a normal state with a value of arg2 A.
Arguments
  • arg1 = sensor name
  • arg2 = current
Detailed Description
The current sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (AMP = Amperage)
Severity
Informational
OMSA Event ID
5202
OMSA Trap ID
5202
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

AMP403

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor state has changed to a warning state with a value of arg2 A.
Arguments
  • arg1 = sensor name
  • arg2 = current
Detailed Description
The current sensor identified in the message is faulty or the current drawn by the system exceeds the warning threshold. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Recommended Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. Otherwise, change the warning threshold for the current sensor such that it corresponds to the hardware configuration.
Category
System Health (AMP = Amperage)
Severity
Warning
OMSA Event ID
5203
OMSA Trap ID
5203
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

AMP404

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor detected an error with a value of arg2 A.
Arguments
  • arg1 = sensor name
  • arg2 = current
Detailed Description
The current sensor identified in the message is faulty or the current drawn by the system exceed the critical threshold. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Recommended Response Action
Review system power policy, check system logs for power related failures, and review system configuration changes. For more information, contact your service provider.
Category
System Health (AMP = Amperage)
Severity
Warning
OMSA Event ID
5204
OMSA Trap ID
5204
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

AMP405

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor state has changed to a failed state with a value of arg2 A.
Arguments
  • arg1 = sensor name
  • arg2 = current
Detailed Description
The current sensor identified in the message may be faulty. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a faulty sensor, replace the system board. For more information, contact your service provider.
Category
System Health (AMP = Amperage)
Severity
Critical
OMSA Event ID
5205
OMSA Trap ID
5205
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\