PowerEdge Servers Error and Event Messages Reference Guide

PDF

BAT—Battery Event Event Messages

BAT0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery is low.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Warning
Trap/EventID
2226
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

BAT0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery is operating normally.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
OMSA Event ID
5702
OMSA Trap ID
5702
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

BAT0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery has failed.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
System board battery has failed. Check battery
OMSA Event ID
5704;5705
OMSA Trap ID
5704
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

BAT0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery is present.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

BAT0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery is absent.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
System board battery is absent. Check battery
OMSA Event ID
5700
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

BAT0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery is low.
Detailed Description
To charge the battery, the system has to remain powered on.
Recommended Response Action
Allow the PERC RAID controller battery to charge. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Warning
Trap/EventID
2226
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery is operating normally.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery has failed.
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
Storage battery has failed. Check battery.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery is present.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery is absent.
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation.2) If installed, reseat or reconnect the battery and cables.3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
Storage battery is absent. Check battery.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery for disk drive bay arg1 is low.
Arguments
  • arg1 = bay
Detailed Description
To charge the battery, the system has to remain powered on.
Recommended Response Action
Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Warning
Trap/EventID
2226
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery for disk drive bay arg1 is operating normally.
Arguments
  • arg1 = bay
Detailed Description
No detailed description available.
Recommended Response Action
Verify the battery installation, check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery for disk drive bay arg1 has failed.
Arguments
  • arg1 = bay
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay.2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> has failed. Check battery.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery for disk drive bay arg1 is present.
Arguments
  • arg1 = bay
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage battery for disk drive bay arg1 is absent.
Arguments
  • arg1 = bay
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> is absent. Check battery.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is low.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Warning
Trap/EventID
2226
LCD Message
The <name> battery is low.
OMSA Event ID
5703
OMSA Trap ID
5703
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is operating normally.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
OMSA Event ID
5702
OMSA Trap ID
5702
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery has failed.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
The <name> battery has failed. Check battery.
OMSA Event ID
5704
OMSA Trap ID
5704
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is present.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
OMSA Event ID
5702
OMSA Trap ID
5702
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is absent.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
The <name> battery is absent. Check battery.
OMSA Event ID
5706
OMSA Trap ID
5706
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is not ready either because the battery is not fully charged or a transient battery event is observed.
Arguments
  • arg1 = name
Detailed Description
The battery identified in the message is not ready either because the battery is not fully charged or a transient battery event is observed.
Recommended Response Action
Wait for 120 minutes for the issue to get cleared. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Warning
Trap/EventID
2226
LCD Message
The <name> battery is not ready. Check battery.
OMSA Event ID
5703
OMSA Trap ID
5703
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery has reached the end of its usable life or has failed.
Arguments
  • arg1 = name
Detailed Description
The battery identified in the message has reached the end of its usable life or has failed.
Recommended Response Action
Manually remove and reinstall the battery. For more information, see the Installation and Service Manual of the server available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Critical
Trap/EventID
2225
LCD Message
The <name> battery has reached the end of its life. Consider replacing battery.
OMSA Event ID
5704
OMSA Trap ID
5704
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

BAT0022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis intrusion detection feature may not function if the input power is disconnected due to the system board battery (CMOS) voltage is low.
Detailed Description
The chassis intrusion detection feature may not function if the input power is disconnected, and the system board battery (CMOS) is not replaced.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Trap/EventID
2227
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT0030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery is reading low.
Detailed Description
The system battery level is low, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the battery.
Category
System Health (BAT = Battery Event)
Severity
Warning
OMSA Event ID
5703
OMSA Trap ID
5703
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

BAT0031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board battery status is unknown.
Detailed Description
The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the battery.
Category
System Health (BAT = Battery Event)
Severity
Warning
OMSA Event ID
5701
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

BAT0033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The NVRAM battery is in an invalid state due to one or more errors.
Detailed Description
The battery of an NVRAM controller is detected to be in an invalid state due to one or more errors.
Recommended Response Action
Contact your service provider / tech support to resolve the issue.
Category
Storage (BAT = Battery Event)
Severity
Critical
Trap/EventID
4273
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

BAT1000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery on arg1 is missing.
Arguments
  • arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message.
Recommended Response Action
Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling. In addition check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may cause this message.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2264
OMSA Trap ID
75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery on arg1 was replaced.
Arguments
  • arg1 = controller name
Detailed Description
A controllers battery was replaced.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2175
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 has started.
Arguments
  • arg1 = controller Name
Detailed Description
The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message has started.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2177
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 is completed.
Arguments
  • arg1 = controller Name
Detailed Description
The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message is completed.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2176
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 has timed out.
Arguments
  • arg1 = controller Name
Detailed Description
The Transparent Learn Cycle (TLC) operation of the energy pack on has timed out because of one of the following reasons.1) The controller energy pack must be fully charged before the learn cycle can begin. The energy pack may be unable to maintain a full charge causing the learn cycle to timeout.2) The energy pack must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some energy packs maintain cached data for 24 hours. If the energy pack is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Recommended Response Action
Do one or more of the following: 1) Perform a Power Cycle operation on the server and check the status of energy pack by using iDRAC User Interface or running the following RACADM command: racadm serveraction powercycle. 2) If energy pack status is not ready replace the energy pack. 3) If still the energy pack is unable to maintain a full charge. Review the Energy Pack Transparent Learn Cycle (TLC) within the Dell PowerEdge Raid Controller User Guide for additional information. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2178
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 is postponed.
Arguments
  • arg1 = controller Name
Detailed Description
The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message is postponed.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2179
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 will start after arg2 days.
Arguments
  • arg1 = controller Name
  • arg2 = number
Detailed Description
The learn cycle will start after specified number of days for the energy pack on controller.
Recommended Response Action
The Transparent Learn Cycle (TLC) operation of the energy pack on the controller will start after the number of days identified in the message.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2180
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 will start in arg2 hours.
Arguments
  • arg1 = controller Name
  • arg2 = arg
Detailed Description
The Transparent Learn Cycle (TLC) operation of the energy pack on controller will start in specified hours.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2181
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Write policy on arg1 was changed to Write Through.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery cannot maintain cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery cannot maintain cached data for 24 hours.
Recommended Response Action
Verify the battery health is good. See the storage hardware documentation to verify battery health. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2188
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Write policy on arg1 was changed to Write Back.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery health has returned to normal.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2189
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery on arg1 requires reconditioning. Initiate a learn cycle.
Arguments
  • arg1 = Controller name
Detailed Description
Battery is in warn only mode and requires reconditioning.
Recommended Response Action
Start a learn cycle on the battery.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2210
OMSA Trap ID
115300
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery on arg1 is in warn only mode and requires reconditioning.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2104
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature of the energy pack on arg1 is more than the normal range.
Arguments
  • arg1 = controller Name
Detailed Description
The temperature of the energy pack on the controller identified in the message is more than the normal range.
Recommended Response Action
Ensure that the cooling fans are properly functioning. This is not an issue related to the battery pack or RAID controller. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Recharge count has exceeded the maximum limit for battery on arg1.
Arguments
  • arg1 = Controller name
Detailed Description
The battery cannot be recharged further.
Recommended Response Action
Replace the battery pack.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2213
OMSA Trap ID
115300
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack on arg1 is charging.
Arguments
  • arg1 = controller
Detailed Description
The energy pack is charging.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2214
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to charge the energy pack on the arg1.
Arguments
  • arg1 = controllerName
Detailed Description
The charging process of the energy pack on the controller identified in the message interrupted.
Recommended Response Action
1) Ensure that the energy pack is installed and properly connected to the controller. For information about cabling, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. 2) If the issue persists, perform a Power Cycle operation. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2215
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery learn mode has changed to Auto.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2216
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery learn mode has changed to Warn.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2217
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery on arg1 is degraded.
Arguments
  • arg1 = Controller name
Detailed Description
The temperature of the battery is high. This may be due to the battery being charged.
Recommended Response Action
If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2246
OMSA Trap ID
115300
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack on the arg1 is getting charged after the server is restarted.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack on the controller identified in the message is getting charged after the server is restarted.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2247
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is executing a learn cycle.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2248
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The charge level of the energy pack on arg1 is less than the normal threshold.
Arguments
  • arg1 = controllerName
Detailed Description
The charge level of the energy pack on the controller identified in the message is less than the normal threshold.
Recommended Response Action
Check for any events that are directly related to the charging of the energy pack. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2278
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 battery recondition is completed.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2105
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1023

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The charge level of the energy pack on arg1 is within the normal threshold.
Arguments
  • arg1 = controller Name
Detailed Description
The charge level of the energy pack on the controller identified in the message is within the normal threshold.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2279
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One or more issues are detected in the energy pack on the arg1.
Arguments
  • arg1 = controllerName
Detailed Description
One of more issues are detected in the energy pack on the controller identified in the message.
Recommended Response Action
Do the following: 1) Verify that the energy pack is present and then check the cabling between controller and battery. 2) Do a power cycle and check the energy pack status. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2318
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1025

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
  • arg1 = controller name
Detailed Description
The controller was unable to recover data from the cache. This may indicate data loss has occurred.
Recommended Response Action
Do one or all of the following: 1) Ensure that the PERC firmware version is updated. 2) Check the battery health. If there are battery issues, replace the battery. Else, replace the PERC card.
Category
Storage (BAT = Battery Event)
Severity
Critical
Trap/EventID
4273
OMSA Event ID
2337
OMSA Trap ID
115400
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1026

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 has recovered cached data from the Battery Backup Unit (BBU).
Arguments
  • arg1 = controller name
Detailed Description
The controller has retrieved cached data.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2338
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1027

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack on the arg1 successfully completed a charge cycle.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack on the controller identified in the message successfully completed a charge cycle.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2358
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The voltage of the energy pack on the arg1 is less than the normal operating range.
Arguments
  • arg1 = controllerName
Detailed Description
The voltage of the energy pack on the controller identified in the message is less than the normal operating range. This may indicate that the energy pack is no longer protecting the controller cache.
Recommended Response Action
1) Ensure that the energy pack is properly charged. 2) Power on the server and enable the energy pack to get charged for 24 hours. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2145
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery on arg1 can no longer recharge.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery cannot recharge. The battery may have already recharged the maximum number of times or the battery charger may not be working.
Recommended Response Action
Do the following and retry the operation: 1) Replace the RAID controller battery. For information about replacing the battery, see the hardware documentation of the respective RAID card. 2) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Critical
Trap/EventID
4273
OMSA Event ID
2169
OMSA Trap ID
115400
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery charge level is normal.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2170
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery temperature on arg1 is above normal.
Arguments
  • arg1 = controller name
Detailed Description
The room temperature may be too hot. In addition, the system fan may be degraded or failed.
Recommended Response Action
Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2171
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature of the energy pack on the arg1 is within the normal operating range.
Arguments
  • arg1 = controllerName
Detailed Description
The temperature of the energy pack on the controller identified in the message is within the normal operating range.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
OMSA Event ID
2172
OMSA Trap ID
115100
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery on arg1 was removed.
Arguments
  • arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
Recommended Response Action
Make sure that the battery is present and properly connected. If the battery is present, wait for a few minutes and re-check if the battery is detected. If the contact point between the battery and the controller is degraded, you must replace the battery, the controller, or both. Refer to the storage hardware documentation for information on how to safely access, or remove. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Trap/EventID
4274
OMSA Event ID
2174
OMSA Trap ID
115300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery properties for arg1 have changed.
Arguments
  • arg1 = controller name
Detailed Description
One or more battery properties were modified.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

BAT1035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery temperature on arg1 is above the normal operating temperature.
Arguments
  • arg1 = controller name
Detailed Description
The battery temperature is above normal operating temperature.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
OMSA Event ID
2212
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

BAT1036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The battery on arg1 is discharging.
Arguments
  • arg1 = controller name
Detailed Description
The battery on the controller identified in the message is being discharged.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
OMSA Event ID
2415
OMSA Trap ID
115100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

BAT1037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A battery is detected on the Controller arg1.
Arguments
  • arg1 = controller name
Detailed Description
A battery is detected on the Controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Trap/EventID
4275
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

BAT1040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect the energy pack on the arg1 because either the energy pack is not installed, or the contact point is degraded.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack on the controller identified in the message cannot be detected because either the energy pack is not installed, or the contact point between the controller and the energy pack is degraded.
Recommended Response Action
Do the following: 1) Ensure that the energy pack is properly connected. 2) If connected, wait few minutes and verify if it is detected. 3) Verify if the connection point between the energy pack and controller is degraded. If degraded, replace the energy pack, PERC, or both. For information about removing and installing an energy pack or PERC, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1041

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to recharge the energy pack on the arg1 because the energy pack may have already recharged the maximum number of times or the energy pack charger may not be working.
Arguments
  • arg1 = controllerName
Detailed Description
The controller energy pack on the controller identified in the message cannot recharge because the energy pack may have already recharged the maximum number of times or the energy pack charger may not be working.
Recommended Response Action
Do the following: 1) Replace the energy pack. For information about removing and installing an energy pack, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. 2) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1042

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack on the arg1 is replaced.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack on the controller identified in the message is replaced.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1043

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect the energy pack because arg1 cannot communicate with the energy pack.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack on the controller identified in the message cannot be detected because of following reasons:1) The controller cannot communicate with the energy pack.2) The energy pack is absent or improperly connected.3) The energy pack with a weak or depleted charge may also cause this message.The controller cache is not protected from power loss.
Recommended Response Action
Ensure that the energy pack is installed and cables are properly connected. For information about cable assembly, see the see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. In addition, check the connection to the controller energy pack and the energy pack health. An energy pack with a weak or depleted charge may cause this issue. If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (BAT = Battery Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1044

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack is detected on the arg1.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack is detected on the controller identified in the message.
Recommended Response Action
No Response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1045

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The energy pack properties for arg1 have changed.
Arguments
  • arg1 = controllerName
Detailed Description
The energy pack properties of the controller identified in the message have changed.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1046

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 energy pack is disabled because of which the energy pack is unable to retain the cached data for the rated duration.
Arguments
  • arg1 = controllerName
Detailed Description
The controller energy pack is unable to retain cached data for the rated duration.
Recommended Response Action
Do the following to resolve the issue: 1) Verify the connection between the connector and the energy pack. 2) Verify the health status of the energy pack. Refer to iDRAC Service Module (ISM) for guidance.
Category
Storage (BAT = Battery Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT1047

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 energy pack health status has returned to normal.
Arguments
  • arg1 = controller name
Detailed Description
The health status of the energy pack of the controller identified in the message has returned to normal.
Recommended Response Action
No Response Action is required.
Category
Storage (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery arg2, with firmware version arg3, is being updated to the firmware version arg4.
Arguments
  • arg1 = type
  • arg2 = id
  • arg3 = curVersion
  • arg4 = newVersion
Detailed Description
The firmware version of the battery identified in the message is being updated.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The firmware version of arg1 battery arg2 is successfully updated.
Arguments
  • arg1 = type
  • arg2 = id
Detailed Description
The firmware version of the battery identified in the message is successfully updated.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the firmware version of arg1 battery arg2.
Arguments
  • arg1 = type
  • arg2 = id
Detailed Description
The firmware version of the battery identified in the message could not be updated.
Recommended Response Action
Perform an AC-cycle operation on the server by disconnecting input power, waiting for 10 seconds, and then reconnecting input power. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the firmware version of arg1 battery arg2.
Arguments
  • arg1 = type
  • arg2 = id
Detailed Description
The firmware version of the battery identified in the message could not be updated.
Recommended Response Action
Check the uploaded firmware image file. Ensure that the image file is compatible with the device manufacturer and the hardware version. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to start the firmware update operation on arg1 battery arg2.
Arguments
  • arg1 = type
  • arg2 = id
Detailed Description
The firmware update operation of the battery identified in the message could not be started.
Recommended Response Action
Ensure the following conditions are met for the update operation: 1) System is powered off. 2) Batteries are installed. 3) There is no active firmware update operation in progress. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (BAT = Battery Event)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

BAT2006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 battery is arg2.
Arguments
  • arg1 = Name
  • arg2 = State
Detailed Description
The battery state of the device identified in the message is reported from the battery register status.
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable