PowerEdge Servers Error and Event Messages Reference Guide
BAT—Battery Event Event Messages
BAT0000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery is low.
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the system board battery at the next service window.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 2226
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
BAT0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery is operating normally.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- OMSA Event ID
- 5702
- OMSA Trap ID
- 5702
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
BAT0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery has failed.
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the system board battery.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- System board battery has failed. Check battery
- OMSA Event ID
- 5704;5705
- OMSA Trap ID
- 5704
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
BAT0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery is present.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
BAT0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery is absent.
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the system board battery to confirm presence.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- System board battery is absent. Check battery
- OMSA Event ID
- 5700
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
BAT0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery is low.
- Detailed Description
- To charge the battery, the system has to remain powered on.
- Recommended Response Action
- Allow the PERC RAID controller battery to charge. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 2226
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery is operating normally.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery has failed.
- Detailed Description
- The PERC RAID controller battery may have failed because of thermal exceptions.
- Recommended Response Action
- 1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- Storage battery has failed. Check battery.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery is present.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery is absent.
- Detailed Description
- The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
- Recommended Response Action
- 1) Verify the PERC RAID controller battery installation.2) If installed, reseat or reconnect the battery and cables.3) Check the system logs for thermal related issues.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- Storage battery is absent. Check battery.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery for disk drive bay arg1 is low.
- Arguments
- arg1 = bay
- Detailed Description
- To charge the battery, the system has to remain powered on.
- Recommended Response Action
- Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 2226
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery for disk drive bay arg1 is operating normally.
- Arguments
- arg1 = bay
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Verify the battery installation, check the system logs for thermal related issues.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery for disk drive bay arg1 has failed.
- Arguments
- arg1 = bay
- Detailed Description
- The PERC RAID controller battery may have failed because of thermal exceptions.
- Recommended Response Action
- 1) Verify the PERC RAID controller battery installation for the associated bay.2) Check the system logs for thermal related issues.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- Battery for disk drive bay <bay> has failed. Check battery.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery for disk drive bay arg1 is present.
- Arguments
- arg1 = bay
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage battery for disk drive bay arg1 is absent.
- Arguments
- arg1 = bay
- Detailed Description
- The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
- Recommended Response Action
- 1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- Battery for disk drive bay <bay> is absent. Check battery.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is low.
- Arguments
- arg1 = name
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the battery at the next service window.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 2226
- LCD Message
- The <name> battery is low.
- OMSA Event ID
- 5703
- OMSA Trap ID
- 5703
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is operating normally.
- Arguments
- arg1 = name
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- OMSA Event ID
- 5702
- OMSA Trap ID
- 5702
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery has failed.
- Arguments
- arg1 = name
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the battery.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- The <name> battery has failed. Check battery.
- OMSA Event ID
- 5704
- OMSA Trap ID
- 5704
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is present.
- Arguments
- arg1 = name
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- OMSA Event ID
- 5702
- OMSA Trap ID
- 5702
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is absent.
- Arguments
- arg1 = name
- Detailed Description
- System settings may be preserved if input power is not removed from the power supplies.
- Recommended Response Action
- Check the battery to confirm presence.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- The <name> battery is absent. Check battery.
- OMSA Event ID
- 5706
- OMSA Trap ID
- 5706
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is not ready either because the battery is not fully charged or a transient battery event is observed.
- Arguments
- arg1 = name
- Detailed Description
- The battery identified in the message is not ready either because the battery is not fully charged or a transient battery event is observed.
- Recommended Response Action
- Wait for 120 minutes for the issue to get cleared. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 2226
- LCD Message
- The <name> battery is not ready. Check battery.
- OMSA Event ID
- 5703
- OMSA Trap ID
- 5703
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery has reached the end of its usable life or has failed.
- Arguments
- arg1 = name
- Detailed Description
- The battery identified in the message has reached the end of its usable life or has failed.
- Recommended Response Action
- Manually remove and reinstall the battery. For more information, see the Installation and Service Manual of the server available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 2225
- LCD Message
- The <name> battery has reached the end of its life. Consider replacing battery.
- OMSA Event ID
- 5704
- OMSA Trap ID
- 5704
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The chassis intrusion detection feature may not function if the input power is disconnected due to the system board battery (CMOS) voltage is low.
- Detailed Description
- The chassis intrusion detection feature may not function if the input power is disconnected, and the system board battery (CMOS) is not replaced.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 2227
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT0030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery is reading low.
- Detailed Description
- The system battery level is low, and if the input power is disconnected, the system settings will not be preserved.
- Recommended Response Action
- Replace the battery.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- OMSA Event ID
- 5703
- OMSA Trap ID
- 5703
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
BAT0031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system board battery status is unknown.
- Detailed Description
- The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved.
- Recommended Response Action
- Replace the battery.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- OMSA Event ID
- 5701
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
BAT0033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The NVRAM battery is in an invalid state due to one or more errors.
- Detailed Description
- The battery of an NVRAM controller is detected to be in an invalid state due to one or more errors.
- Recommended Response Action
- Contact your service provider / tech support to resolve the issue.
- Category
- Storage (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 4273
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
BAT1000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Battery on arg1 is missing.
- Arguments
- arg1 = controller name
- Detailed Description
- The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message.
- Recommended Response Action
- Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling. In addition check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may cause this message.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2264
- OMSA Trap ID
- 75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Battery on arg1 was replaced.
- Arguments
- arg1 = controller name
- Detailed Description
- A controllers battery was replaced.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2175
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 has started.
- Arguments
- arg1 = controller Name
- Detailed Description
- The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message has started.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2177
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 is completed.
- Arguments
- arg1 = controller Name
- Detailed Description
- The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message is completed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2176
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 has timed out.
- Arguments
- arg1 = controller Name
- Detailed Description
- The Transparent Learn Cycle (TLC) operation of the energy pack on has timed out because of one of the following reasons.1) The controller energy pack must be fully charged before the learn cycle can begin. The energy pack may be unable to maintain a full charge causing the learn cycle to timeout.2) The energy pack must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some energy packs maintain cached data for 24 hours. If the energy pack is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
- Recommended Response Action
- Do one or more of the following: 1) Perform a Power Cycle operation on the server and check the status of energy pack by using iDRAC User Interface or running the following RACADM command: racadm serveraction powercycle. 2) If energy pack status is not ready replace the energy pack. 3) If still the energy pack is unable to maintain a full charge. Review the Energy Pack Transparent Learn Cycle (TLC) within the Dell PowerEdge Raid Controller User Guide for additional information. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2178
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 is postponed.
- Arguments
- arg1 = controller Name
- Detailed Description
- The Transparent Learn Cycle (TLC) operation of the energy pack on the controller identified in the message is postponed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2179
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 will start after arg2 days.
- Arguments
- arg1 = controller Name
- arg2 = number
- Detailed Description
- The learn cycle will start after specified number of days for the energy pack on controller.
- Recommended Response Action
- The Transparent Learn Cycle (TLC) operation of the energy pack on the controller will start after the number of days identified in the message.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2180
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Transparent Learn Cycle (TLC) operation of the energy pack on arg1 will start in arg2 hours.
- Arguments
- arg1 = controller Name
- arg2 = arg
- Detailed Description
- The Transparent Learn Cycle (TLC) operation of the energy pack on controller will start in specified hours.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2181
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Write policy on arg1 was changed to Write Through.
- Arguments
- arg1 = controller name
- Detailed Description
- The controller battery cannot maintain cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery cannot maintain cached data for 24 hours.
- Recommended Response Action
- Verify the battery health is good. See the storage hardware documentation to verify battery health. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2188
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Write policy on arg1 was changed to Write Back.
- Arguments
- arg1 = controller name
- Detailed Description
- The controller battery health has returned to normal.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2189
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Battery on arg1 requires reconditioning. Initiate a learn cycle.
- Arguments
- arg1 = Controller name
- Detailed Description
- Battery is in warn only mode and requires reconditioning.
- Recommended Response Action
- Start a learn cycle on the battery.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2210
- OMSA Trap ID
- 115300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Battery on arg1 is in warn only mode and requires reconditioning.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2104
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The temperature of the energy pack on arg1 is more than the normal range.
- Arguments
- arg1 = controller Name
- Detailed Description
- The temperature of the energy pack on the controller identified in the message is more than the normal range.
- Recommended Response Action
- Ensure that the cooling fans are properly functioning. This is not an issue related to the battery pack or RAID controller. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Recharge count has exceeded the maximum limit for battery on arg1.
- Arguments
- arg1 = Controller name
- Detailed Description
- The battery cannot be recharged further.
- Recommended Response Action
- Replace the battery pack.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2213
- OMSA Trap ID
- 115300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack on arg1 is charging.
- Arguments
- arg1 = controller
- Detailed Description
- The energy pack is charging.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2214
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to charge the energy pack on the arg1.
- Arguments
- arg1 = controllerName
- Detailed Description
- The charging process of the energy pack on the controller identified in the message interrupted.
- Recommended Response Action
- 1) Ensure that the energy pack is installed and properly connected to the controller. For information about cabling, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. 2) If the issue persists, perform a Power Cycle operation. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2215
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery learn mode has changed to Auto.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2216
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery learn mode has changed to Warn.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2217
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Battery on arg1 is degraded.
- Arguments
- arg1 = Controller name
- Detailed Description
- The temperature of the battery is high. This may be due to the battery being charged.
- Recommended Response Action
- If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2246
- OMSA Trap ID
- 115300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack on the arg1 is getting charged after the server is restarted.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack on the controller identified in the message is getting charged after the server is restarted.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2247
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is executing a learn cycle.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2248
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The charge level of the energy pack on arg1 is less than the normal threshold.
- Arguments
- arg1 = controllerName
- Detailed Description
- The charge level of the energy pack on the controller identified in the message is less than the normal threshold.
- Recommended Response Action
- Check for any events that are directly related to the charging of the energy pack. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2278
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 battery recondition is completed.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2105
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1023
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The charge level of the energy pack on arg1 is within the normal threshold.
- Arguments
- arg1 = controller Name
- Detailed Description
- The charge level of the energy pack on the controller identified in the message is within the normal threshold.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2279
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more issues are detected in the energy pack on the arg1.
- Arguments
- arg1 = controllerName
- Detailed Description
- One of more issues are detected in the energy pack on the controller identified in the message.
- Recommended Response Action
- Do the following: 1) Verify that the energy pack is present and then check the cabling between controller and battery. 2) Do a power cycle and check the energy pack status. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2318
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
- Arguments
- arg1 = controller name
- Detailed Description
- The controller was unable to recover data from the cache. This may indicate data loss has occurred.
- Recommended Response Action
- Do one or all of the following: 1) Ensure that the PERC firmware version is updated. 2) Check the battery health. If there are battery issues, replace the battery. Else, replace the PERC card.
- Category
- Storage (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 4273
- OMSA Event ID
- 2337
- OMSA Trap ID
- 115400
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 has recovered cached data from the Battery Backup Unit (BBU).
- Arguments
- arg1 = controller name
- Detailed Description
- The controller has retrieved cached data.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2338
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack on the arg1 successfully completed a charge cycle.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack on the controller identified in the message successfully completed a charge cycle.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2358
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The voltage of the energy pack on the arg1 is less than the normal operating range.
- Arguments
- arg1 = controllerName
- Detailed Description
- The voltage of the energy pack on the controller identified in the message is less than the normal operating range. This may indicate that the energy pack is no longer protecting the controller cache.
- Recommended Response Action
- 1) Ensure that the energy pack is properly charged. 2) Power on the server and enable the energy pack to get charged for 24 hours. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2145
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery on arg1 can no longer recharge.
- Arguments
- arg1 = controller name
- Detailed Description
- The controller battery cannot recharge. The battery may have already recharged the maximum number of times or the battery charger may not be working.
- Recommended Response Action
- Do the following and retry the operation: 1) Replace the RAID controller battery. For information about replacing the battery, see the hardware documentation of the respective RAID card. 2) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Critical
- Trap/EventID
- 4273
- OMSA Event ID
- 2169
- OMSA Trap ID
- 115400
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery charge level is normal.
- Arguments
- arg1 = Controller name
- Detailed Description
- This alert is provided for informational purposes.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2170
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery temperature on arg1 is above normal.
- Arguments
- arg1 = controller name
- Detailed Description
- The room temperature may be too hot. In addition, the system fan may be degraded or failed.
- Recommended Response Action
- Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2171
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The temperature of the energy pack on the arg1 is within the normal operating range.
- Arguments
- arg1 = controllerName
- Detailed Description
- The temperature of the energy pack on the controller identified in the message is within the normal operating range.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- OMSA Event ID
- 2172
- OMSA Trap ID
- 115100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery on arg1 was removed.
- Arguments
- arg1 = controller name
- Detailed Description
- The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
- Recommended Response Action
- Make sure that the battery is present and properly connected. If the battery is present, wait for a few minutes and re-check if the battery is detected. If the contact point between the battery and the controller is degraded, you must replace the battery, the controller, or both. Refer to the storage hardware documentation for information on how to safely access, or remove. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Trap/EventID
- 4274
- OMSA Event ID
- 2174
- OMSA Trap ID
- 115300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery properties for arg1 have changed.
- Arguments
- arg1 = controller name
- Detailed Description
- One or more battery properties were modified.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
BAT1035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery temperature on arg1 is above the normal operating temperature.
- Arguments
- arg1 = controller name
- Detailed Description
- The battery temperature is above normal operating temperature.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- OMSA Event ID
- 2212
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
BAT1036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The battery on arg1 is discharging.
- Arguments
- arg1 = controller name
- Detailed Description
- The battery on the controller identified in the message is being discharged.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- OMSA Event ID
- 2415
- OMSA Trap ID
- 115100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
BAT1037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A battery is detected on the Controller arg1.
- Arguments
- arg1 = controller name
- Detailed Description
- A battery is detected on the Controller identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Trap/EventID
- 4275
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1040
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to detect the energy pack on the arg1 because either the energy pack is not installed, or the contact point is degraded.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack on the controller identified in the message cannot be detected because either the energy pack is not installed, or the contact point between the controller and the energy pack is degraded.
- Recommended Response Action
- Do the following: 1) Ensure that the energy pack is properly connected. 2) If connected, wait few minutes and verify if it is detected. 3) Verify if the connection point between the energy pack and controller is degraded. If degraded, replace the energy pack, PERC, or both. For information about removing and installing an energy pack or PERC, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1041
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to recharge the energy pack on the arg1 because the energy pack may have already recharged the maximum number of times or the energy pack charger may not be working.
- Arguments
- arg1 = controllerName
- Detailed Description
- The controller energy pack on the controller identified in the message cannot recharge because the energy pack may have already recharged the maximum number of times or the energy pack charger may not be working.
- Recommended Response Action
- Do the following: 1) Replace the energy pack. For information about removing and installing an energy pack, see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. 2) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1042
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack on the arg1 is replaced.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack on the controller identified in the message is replaced.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1043
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to detect the energy pack because arg1 cannot communicate with the energy pack.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack on the controller identified in the message cannot be detected because of following reasons:1) The controller cannot communicate with the energy pack.2) The energy pack is absent or improperly connected.3) The energy pack with a weak or depleted charge may also cause this message.The controller cache is not protected from power loss.
- Recommended Response Action
- Ensure that the energy pack is installed and cables are properly connected. For information about cable assembly, see the see the respective PERC Users Guide or the Installation and Service Manual (ISM) of the respective server platform on the support site. In addition, check the connection to the controller energy pack and the energy pack health. An energy pack with a weak or depleted charge may cause this issue. If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1044
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack is detected on the arg1.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack is detected on the controller identified in the message.
- Recommended Response Action
- No Response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1045
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The energy pack properties for arg1 have changed.
- Arguments
- arg1 = controllerName
- Detailed Description
- The energy pack properties of the controller identified in the message have changed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1046
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 energy pack is disabled because of which the energy pack is unable to retain the cached data for the rated duration.
- Arguments
- arg1 = controllerName
- Detailed Description
- The controller energy pack is unable to retain cached data for the rated duration.
- Recommended Response Action
- Do the following to resolve the issue: 1) Verify the connection between the connector and the energy pack. 2) Verify the health status of the energy pack. Refer to iDRAC Service Module (ISM) for guidance.
- Category
- Storage (BAT = Battery Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT1047
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 energy pack health status has returned to normal.
- Arguments
- arg1 = controller name
- Detailed Description
- The health status of the energy pack of the controller identified in the message has returned to normal.
- Recommended Response Action
- No Response Action is required.
- Category
- Storage (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery arg2, with firmware version arg3, is being updated to the firmware version arg4.
- Arguments
- arg1 = type
- arg2 = id
- arg3 = curVersion
- arg4 = newVersion
- Detailed Description
- The firmware version of the battery identified in the message is being updated.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The firmware version of arg1 battery arg2 is successfully updated.
- Arguments
- arg1 = type
- arg2 = id
- Detailed Description
- The firmware version of the battery identified in the message is successfully updated.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware version of arg1 battery arg2.
- Arguments
- arg1 = type
- arg2 = id
- Detailed Description
- The firmware version of the battery identified in the message could not be updated.
- Recommended Response Action
- Perform an AC-cycle operation on the server by disconnecting input power, waiting for 10 seconds, and then reconnecting input power. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware version of arg1 battery arg2.
- Arguments
- arg1 = type
- arg2 = id
- Detailed Description
- The firmware version of the battery identified in the message could not be updated.
- Recommended Response Action
- Check the uploaded firmware image file. Ensure that the image file is compatible with the device manufacturer and the hardware version. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the firmware update operation on arg1 battery arg2.
- Arguments
- arg1 = type
- arg2 = id
- Detailed Description
- The firmware update operation of the battery identified in the message could not be started.
- Recommended Response Action
- Ensure the following conditions are met for the update operation: 1) System is powered off. 2) Batteries are installed. 3) There is no active firmware update operation in progress. Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (BAT = Battery Event)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
BAT2006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 battery is arg2.
- Arguments
- arg1 = Name
- arg2 = State
- Detailed Description
- The battery state of the device identified in the message is reported from the battery register status.
- Recommended Response Action
- No response action is required.
- Category
- System Health (BAT = Battery Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable