PowerEdge Servers Error and Event Messages Reference Guide

PDF

CDEV—Devices Event Messages

CDEV0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve inventory information for the device.
Detailed Description
Inventory information is not available for the requested device.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV0024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update Services Configuration arg1 for arg2 because of arg3.
Arguments
  • arg1 = version
  • arg2 = type
  • arg3 = reason
Detailed Description
Unable to update Services Configurations due to reason mentioned in message.
Recommended Response Action
Retry operation after sometime. If issue persists, contact your service provider.
Category
Audit (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV0100

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Proxy settings modified.
Detailed Description
Proxy settings modified.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV0102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the requested operation because an invalid JSON file is entered.
Detailed Description
The requested operation cannot be completed because an invalid JSON file is entered.
Recommended Response Action
Enter a valid JSON file name and retry the operation. For more information about supported file types, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV0103

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the request to remove the chassis arg1 from the Multi-chassis Management group arg2.
Arguments
  • arg1 = Chassis Service Tag
  • arg2 = groupName
Detailed Description
The request to remove the chassis from the Multi-chassis Management group identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider. For more information see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV0104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD Override PIN modified.
Detailed Description
LCD Override PIN is modified successfully.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A request to send an email was successfully completed. The request came from arg1.
Arguments
  • arg1 = name
Detailed Description
An email send request was successfully completed.
Recommended Response Action
N/A.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A request to send an email failed. The origin of the request came from arg1.
Arguments
  • arg1 = name
Detailed Description
An email send request failed.
Recommended Response Action
Verify that the SMTP configuration is valid in your appliance alert settings and make sure that the remote SMTP destination is available.
Category
Audit (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The appliance couldnt send credential emails for arg1 out of arg2 users. The request was initiated by arg3.
Arguments
  • arg1 = count_of_users_email_failed
  • arg2 = total_count_of_users
  • arg3 = name
Detailed Description
The appliance was unable to send credential emails to some of the selected users.
Recommended Response Action
Retry the Email Login Details operation.
Category
Audit (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power usage details are not applicable for this device.
Detailed Description
Power usage information cannot be displayed because it is not applicable to this device.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1108

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the Multi Chassis Management domain group.
Detailed Description
The Multi Chassis Management domain group could not be created.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1109

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the Multi Chassis Management domain group because no chassis was found.
Detailed Description
The Multi Chassis Management domain group cannot be createdbecause no chassis was found.
Recommended Response Action
Retry the operation. If the issue persists contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1111

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve arg1 information for Multi Chassis Management.
Arguments
  • arg1 = data
Detailed Description
The information identified in the message cannot be retrieved.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1112

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add members to the Multi Chassis Management group because no group is available.
Detailed Description
New members cannot be added to the Multi Chassis Management group because no group is available.
Recommended Response Action
Create a Multi Chassis Management group and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1113

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the member chassis to the Multi-chassis Management group.
Detailed Description
The member chassis could not be added to the Multi-chassis Management group.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the member chassis to the Multi-chassis Management group because only the lead chassis can approve requests for joining.
Detailed Description
The member chassis cannot be added to the Multi-chassis Management group because only the lead chassis can approve requests for joining.
Recommended Response Action
Retry the operation by using the lead chassis of the Multi-chassis Management group.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1115

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to approve the join request from the member chassis.
Detailed Description
The join request from the member chassis could not be approved.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1116

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to broadcast the Multi Chassis Management group creation over mDNS.
Detailed Description
The Multi Chassis Management group creation could not be broadcast over mDNS.
Recommended Response Action
Retry the operation. If the issue persists, contact your network administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1117

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to join the Multi-chassis Management group.
Detailed Description
Unable to join the Multi-chassis Management group.
Recommended Response Action
Make sure the Multi-chassis Management group is available and retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1118

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to join the Multi-chassis Management group arg1 because the chassis is already a member.
Arguments
  • arg1 = group UUID
Detailed Description
Unable to join the Multi-chassis Management group identified in the message because the chassis is already a member.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1119

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to join the Multi-chassis Management group because discovered groups are unavailable.
Detailed Description
Unable to join the Multi-chassis Management group because discovered groups are unavailable.
Recommended Response Action
Make sure the requested group is available and retry the operation. If the issue persists, contact your network administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1120

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to join the Multi-chassis Management group because the entered lead group arg1 is unavailable.
Arguments
  • arg1 = lead group
Detailed Description
The Multi-chassis Management group cannot be joined because the entered lead chassis IP is unavailable.
Recommended Response Action
Make sure the lead group identified in the message is available and retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1121

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve the status of requests opened for joining the Multi-chassis Management group.
Detailed Description
The status of requests opened to join the Multi-chassis Management group cannot be retrieved.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1122

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis is unable to complete the network operation arg1 because of internal issues. Fabric Manager message: arg2. Internal message ID: arg3.
Arguments
  • arg1 = operation Name
  • arg2 = message
  • arg3 = error Event Message Code
Detailed Description
The chassis is unable to complete the network operation identified in the message.
Recommended Response Action
Wait for few minutes and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1123

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform operation, because the fabric manager was not reachable.
Detailed Description
The given operation failed, because the fabric manager was not reachable.
Recommended Response Action
Make sure of the following and retry the operation: 1) There is at least one advanced I/O Module in power-on mode. For example, MX9116n Ethernet Switch and MX5108n Ethernet Switch. However, if an advanced I/O Module is available in the power-on mode, make sure that the network profile is not set when the fabric manager is in the switch-over mode. 2) If the issue persists, wait for few minutes and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1124

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis is unable to complete the network operation arg1 because invalid input/configuration is provided.
Arguments
  • arg1 = arg1
Detailed Description
The chassis is unable to complete the network operation identified in the message.
Recommended Response Action
Verify the error identified in the message, correct it and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1125

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to delete the network arg1 because invalid network name is entered. Fabric Manager message: arg2. Internal message ID: arg3.
Arguments
  • arg1 = network Name
  • arg2 = message
  • arg3 = error Event Message Code
Detailed Description
The chassis is unable to delete the network identified in the message because invalid network name is entered.
Recommended Response Action
Enter valid network name and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1126

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the attribute arg1 entered for the property arg2 is either invalid or of a different type.
Arguments
  • arg1 = attribute Name
  • arg2 = property Name
Detailed Description
The operation cannot be completed because the attribute entered for the property is either invalid or of a different type as identified in the message.
Recommended Response Action
Enter a valid and correct attribute that is compatible with the identified property, and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1127

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the attribute arg1 entered for the property arg2 is not supported.
Arguments
  • arg1 = attribute Name
  • arg2 = property Name
Detailed Description
The operation cannot be completed because the attribute entered for the property is not supported as identified in the message.
Recommended Response Action
Enter a valid and correct attribute, and then retry the operation. For example, if the character length of a property is more than the max permitted, reenter the property as recommended. For more information about recommended attributes for properties, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1128

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the task arg1 because an invalid parameter arg2 is entered.
Arguments
  • arg1 = task Name
  • arg2 = parameter Name
Detailed Description
The task identified in the message cannot be completed because an invalid parameter is entered.
Recommended Response Action
Enter a valid and correct parameter, and then retry the operation. For more information about valid parameters, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1129

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because of an internal service error. However, the service is still running.
Detailed Description
The operation cannot be completed because of an internal service error. However, the service is still running.
Recommended Response Action
Retry the operation. If the issue persists, reset the service.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1130

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A general error has occurred. See ExtendedInfo for more information.
Detailed Description
The operation cannot be completed because of an internal error.
Recommended Response Action
See ExtendedInfo for more information.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1131

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the create operation because the property arg1 is not entered.
Arguments
  • arg1 = property Name
Detailed Description
The operation cannot be completed because the property identified in the message is not entered.
Recommended Response Action
Enter a valid property name and retry the operation. For more information, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1132

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the parameter arg1 entered is not supported on the target device for completing the task arg2.
Arguments
  • arg1 = parameter Name
  • arg2 = task Name
Detailed Description
The operation cannot be completed because the parameter entered is not supported on the target device for completing the task as identified in the message.
Recommended Response Action
Enter a valid parameter and retry the operation. For more information, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1133

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform operation on provided network profile, because the fabric manager was not reachable.
Detailed Description
The operation cannot be performed on the network profile identified in the message because the fabric manager was not reachable.
Recommended Response Action
Make sure of the following and retry the operation: 1) There is at least one advanced I/O Module in power-on mode. For example, MX9116n Ethernet Switch and MX5108n Ethernet Switch. However, if an advanced I/O Module is available in the power-on mode, make sure that the network profile is not set when the fabric manager is in the switch-over mode. 2) If the issue persists, wait for few minutes and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1134

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or update the uplink because there is no valid network profile associated to the Native VLAN entered: arg1.
Arguments
  • arg1 = arg1
Detailed Description
The uplink cannot be created or updated because there is no valid network profile associated to the native VLAN entered.
Recommended Response Action
Please use one of the available network profiles in the system. If a network profile with the VLAN entered does not exist, please create a new one.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1135

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or update the FCoE uplink, because the firmware version of the I/O Module running the Fabric Manager does not support Native VLAN configuration for FCoE uplinks.
Detailed Description
The FCoE uplink cannot be created or updated, because the firmware version of the I/O Module running the Fabric Manager does not support Native VLAN configuration for FCoE uplinks.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1136

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform operation. The request(s) to fabric manager timed out.
Detailed Description
Unable to perform operation. The request(s) to fabric manager timed out.
Recommended Response Action
Fabric Manager is busy processing other requests, please wait for few minutes and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1137

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A new right control panel is detected in the chassis.
Detailed Description
A new right control panel is detected in the chassis.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1138

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The automatic restoration of chassis settings is completed on the right control panel.
Detailed Description
The automatic restoration of chassis settings is completed on the right control panel.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1139

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The automatic restoration of chassis settings, job arg1, is either unsuccessful or completed with warnings on the right control panel.
Arguments
  • arg1 = jobID
Detailed Description
The automatic restoration of chassis settings is either unsuccessful orcompleted with warnings on the right control panel.
Recommended Response Action
View the job data and recommended resolution. To view job data onthe Graphical User Interface (GUI), click Monitor-> Jobs. To view job data byrunning REST command, enter the following at the Command Line Interface (CLI): Jobs(<jobId>).
Category
Audit (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV1140

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A tampered right control panel is detected in the chassis.
Detailed Description
A tampered right control panel is detected in the chassis.
Recommended Response Action
Replace with a pristine right control panel in the chassis. For steps about replacing, see the hardware documentation of the respective chassis available on the support site.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The leader chassis of the Multi-Chassis Management group does not have a backup chassis.
Detailed Description
The leader chassis of the Multi-Chassis Management (MCM) group does not have a backup chassis.
Recommended Response Action
Assign a member of the group as the backup chassis. For information about assigning a backup chassis, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Multi-Chassis Management group lead redundancy is lost because of either network issues or firmware version mismatch.
Detailed Description
The Redundancy feature of the Multi-Chassis Management (MCM) group lead chassis is unavailable anymore either because of network issues or difference in the firmware version of lead and backup chassis.
Recommended Response Action
Do the following: 1) Check the network cables that connect the management ports between the chassis. 2) Make sure that the firmware version of the lead and backup chassis are same. If the issue persists, unassign the backup chassis and reassign. For information about assigning a backup chassis, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Redundancy feature of the Multi-Chassis Management (MCM) group lead chassis is degraded.
Detailed Description
The Redundancy feature of the Multi-Chassis Management (MCM) group lead chassis is degraded.
Recommended Response Action
No response action is required. The configuration data of the Multi-Chassis Management (MCM) will be automatically recovered and synchronized. If condition persists, unassign the backup and repeat the assign backup operation.
Category
System Health (CDEV = Devices)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to replicate the Multi-Chassis Management data to the backup chassis arg1 because the service is interrupted.
Arguments
  • arg1 = service tag
Detailed Description
The Multi-Chassis Management data cannot be replicated to the backup chassis identified in the message because the service is interrupted.
Recommended Response Action
Wait for the Management Module to automatically update the replication data. If the issue persists, unassign the backup chassis and reassign the same chassis as a backup.
Category
System Health (CDEV = Devices)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Multi-Chassis Management (MCM) lead chassis is unable to communicate with the backup chassis arg1 because of network issues.
Arguments
  • arg1 = service tag
Detailed Description
The Multi-Chassis Management (MCM) lead chassis cannot communicate with the backup chassis identified in the message because of network issues.
Recommended Response Action
Do the following: 1) Check the network cables that connect the management ports between the chassis. 2) If a cable issue is not found, but the lead chassis is still inaccessible by using its management IP, promote the backup chassis as the lead chassis. For information about assigning a lead chassis, see the OpenManage Enterprise-Modular User Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to replicate Multi-Chassis Management data from lead to backup chassis arg1 because of a firmware version mismatch between both the chassis.
Arguments
  • arg1 = service tag
Detailed Description
The Multi-Chassis Management data cannot be replicated from the lead to the backup chassis identified in the message because of a firmware mismatch between both the chassis.
Recommended Response Action
Make sure that the firmware version of both the lead and backup chassis is same and retry the operation. For information about updating the firmware version of an Multi-Chassis Management (MCM), see the OpenManage Enterprise-Modular User Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to replicate the Multi-Chassis Management data from lead to backup chassis arg1 because of internal issues.
Arguments
  • arg1 = service tag
Detailed Description
Data between the Multi-Chassis Management (MCM) lead and backup chassis cannot be synchronized because of internal issues.
Recommended Response Action
Unassign the backup chassis, reassign, and then retry the operation. If the issue persists, contact your service provider. For information about assigning a Multi-Chassis Management (MCM) backup chassis, see the OpenManage Enterprise-Modular User Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to replicate the Multi-Chassis Management data from the lead chassis arg1 because the service is interrupted.
Arguments
  • arg1 = service tag
Detailed Description
The Multi-Chassis Management data cannot be replicated from the lead chassis identified in the message because the service is interrupted.
Recommended Response Action
The management module will attempt to automatically bring data replication up to date. If condition persists, unassign the backup and repeat the assign backup operation. If lead chassis is not available, promote the backup chassis as lead.
Category
System Health (CDEV = Devices)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Redundancy feature of the Multi-Chassis Management (MCM) group lead chassis is restored.
Detailed Description
The Redundancy feature of the Multi-Chassis Management (MCM) group lead chassis is restored.
Recommended Response Action
No response action required.
Category
System Health (CDEV = Devices)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV4028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve inventory data because of an unknown issue.
Detailed Description
The inventory data cannot be retrieved because of an unknown issue.
Recommended Response Action
Check the log data and retry the operation. For information about checking log data, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the network profile, arg1, associated with the untagged VLAN that is entered is of FCoE type.
Arguments
  • arg1 = network Name
Detailed Description
The operation cannot be completed because the network profile associated with the untagged VLAN that is entered is of FCoE type.
Recommended Response Action
Do the following and retry the operation: 1) Enter the same value for both VLAN minimum and maximum 2) Select a VLAN type of anything other than FCoE.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the server profile : arg1, because arg2.
Arguments
  • arg1 = Server Profile Id
  • arg2 = message
Detailed Description
The server profile cannot be updated because of the issue identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The server profile : arg1 is successfully updated.
Arguments
  • arg1 = Server Profile Id
Detailed Description
The server profile identified in the message is successfully updated.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the server profile, arg1, does not exist in the Fabric Manager.
Arguments
  • arg1 = Server Profile ID
Detailed Description
The operation cannot be completed because the server profile identified in the message does not exist in the Fabric Manager.
Recommended Response Action
Do the following and retry the operation: 1) Deploy a new server profile on the server. For information about deploying a server profile see the OpenManage Enterprise-Modular Users Guide available on the support site. 2) Enter a valid server profile ID.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the network properties because the VLAN minimum arg1 must be equal to VLAN maximum arg2.
Arguments
  • arg1 = min Vlan
  • arg2 = max Vlan
Detailed Description
The network properties cannot be updated because the VLAN minimum must be equal to VLAN maximum as identified in the message.
Recommended Response Action
Enter the same value for both VLAN minimum and maximum and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV5010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Untagged VLAN cannot be configured because the value provided in the request does not exist.
Detailed Description
The Untagged VLAN cannot be configuredbecause the valueprovided in the request does not exist.
Recommended Response Action
Enter the valid Untagged VLAN and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to establish a network connection with the target device.
Detailed Description
The operation cannot be completed because a communication error occurred.
Recommended Response Action
Make sure the target device is available and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to connect to the URL arg1.
Arguments
  • arg1 = url
Detailed Description
The operation cannot be completed with the specified URL.
Recommended Response Action
Make sure the entered URL is correct and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to open the URL arg1 because it is malformed.
Arguments
  • arg1 = url
Detailed Description
The operation cannot be completed with the specified URL.
Recommended Response Action
Enter a valid URL and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to open the location arg1 because the path or URL is invalid.
Arguments
  • arg1 = url
Detailed Description
The operation cannot be completed because the specified path or URL is invalid.
Recommended Response Action
Enter a valid path or URL and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to access the file on the remote share either because of network connection issues or credentials are not saved to provide access rights.
Detailed Description
The file on the remote share cannot be accessed either because of network connection issues or credentials are not saved to provide access rights.
Recommended Response Action
Make sure that the share path and credentials are correct and that the share is accessible and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to write to the local file or temp file either because the file path is invalid or a file with the same name already exists in the folder.
Detailed Description
Cannot write to the local file or temp file either because the file path is invalid or a file with the same name already exists in the folder.
Recommended Response Action
Make sure that the correct file path is entered and that a file with the same name does not already exist in the folder.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the remote file arg1 either because the file is not available on the remote share or the share is not accessible.
Arguments
  • arg1 = fileName
Detailed Description
Cannot read the remote file either because the file is not available on the remote share or the share is not accessible.
Recommended Response Action
Make sure that the file exists on the remote share and that the share is accessible.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the remote file arg1 because the remote file is not available.
Arguments
  • arg1 = file name
Detailed Description
Cannot read the remote file because the remote file is not available.
Recommended Response Action
Make sure the file exists on the remote location or URL and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the remote file because the file path or URL arg1 is invalid.
Arguments
  • arg1 = path
Detailed Description
Cannot read the remote file because the file path or URL is invalid.
Recommended Response Action
Make sure that the file path or URL is valid and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to access the URL arg1 because of restricted permissions.
Arguments
  • arg1 = URL
Detailed Description
The URL cannot be access because of restricted permissions.
Recommended Response Action
Make sure that necessary user access rights are provided and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to execute the command because the target device IP is not reachable: arg1.
Arguments
  • arg1 = message
Detailed Description
The operation cannot be completed because the target device IP is not reachable.
Recommended Response Action
Make sure that the target device is available and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to start network connection because a communication error occurred.
Detailed Description
The network connection cannot be started because a communication error occurred.
Recommended Response Action
Retry the operation. If the issue persists, contact your network administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process action because the operation is not supported by the target device.
Detailed Description
The operation cannot be completed because it is not supported by the target device.
Recommended Response Action
Make sure the requested action is supported and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the action because there is no associated protocol for the action arg1 and device type arg2.
Arguments
  • arg1 = action name
  • arg2 = device type
Detailed Description
The operation cannot be completed because there is no associated protocol as identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to upload the Field Service Debug (FSD) certificate because the device ID entered does not exist.
Detailed Description
The Field Service Debug (FSD) certificate cannot be uploaded because the device ID entered does not exist.
Recommended Response Action
Enter a valid device ID and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6041

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
FSD dat file downloaded.
Detailed Description
User initiated FSD dat file download.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6042

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
FSD dat file uploaded.
Detailed Description
User uploaded FSD dat file.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6043

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
SSH key file uploaded.
Detailed Description
User uploaded SSH key file.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6044

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to discover the available chassis domains.
Detailed Description
The available chassis domains cannot be discovered.
Recommended Response Action
Make sure that the network is available and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6046

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The creation request for fabric arg1 was successfully submitted.
Arguments
  • arg1 = fabric
Detailed Description
The create request for fabric identified in the message was successful.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6047

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The fabric arg1 is successfully updated.
Arguments
  • arg1 = fabric
Detailed Description
The fabric identified in the message is successfully updated.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6048

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The deletion request for fabric arg1 was successfully submitted.
Arguments
  • arg1 = arg1
Detailed Description
The deletion request for fabric identified in the message was successfully submitted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6049

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the fabric arg1.
Arguments
  • arg1 = fabric
Detailed Description
The fabric identified in the message could not be created.
Recommended Response Action
Enter valid fabric parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6050

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the fabric arg1.
Arguments
  • arg1 = fabric
Detailed Description
The fabric identified in the message cannot be updated because invalid fabric parameters are entered.
Recommended Response Action
Enter valid fabric parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6051

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The deletion request for fabric arg1.
Arguments
  • arg1 = fabric
Detailed Description
The fabric identified in the message could not be deleted.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6052

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The uplink arg1 for fabric arg2 is successfully created.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink is successfully created for the fabric identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6053

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The uplink arg1 for fabric arg2 is successfully updated.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink is successfully updated for the fabric identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6054

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The uplink arg1 for fabric arg2 is successfully deleted.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink is successfully deleted for the fabric identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6055

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the uplink arg1 for fabric arg2.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink cannot not be created for the fabric identified in the message.
Recommended Response Action
Enter valid uplink parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6056

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the uplink arg1 for fabric arg2.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink cannot be updated for the fabric identified in the message.
Recommended Response Action
Enter valid uplink parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6057

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to delete the uplink arg1 for fabric arg2.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink cannot be deleted for the fabric identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6058

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the specified fabric resource does not exist.
Detailed Description
The operation cannot be completed because the specified fabric resource does not exist.
Recommended Response Action
Make sure that the fabric data entered is valid and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6060

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation arg1 because the device did not respond.
Arguments
  • arg1 = operation
Detailed Description
The operation identified in the message cannot be completed because the device did not return respond.
Recommended Response Action
Make sure that the device is available and supports the operation, and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6065

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to delete the fabric(s) arg1.
Arguments
  • arg1 = fabrics
Detailed Description
The fabric(s) identified in the message cannot be deleted.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6066

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to delete the uplink(s) arg1 for fabric arg2.
Arguments
  • arg1 = uplink
  • arg2 = fabric
Detailed Description
The uplink(s) could not be deleted for the fabric identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6067

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the fabric because the attribute arg1 cannot be edited.
Arguments
  • arg1 = attributeName
Detailed Description
The fabric cannot be updated because the attribute identified in the message cannot be edited.
Recommended Response Action
Omit the attribute from the payload and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6071

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or update network controller information.
Detailed Description
The network controller information cannot be created or updated.
Recommended Response Action
Enter valid network controller information and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6072

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve the member information because member ID arg1 entered does not exist.
Arguments
  • arg1 = member ID
Detailed Description
The member information cannot be retrieved because member ID entered identified in the message does not exist.
Recommended Response Action
Enter a valid member ID and retry the operation. For information about valid member IDs, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6074

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to set the default password because autodiscovery has not yet completed.
Detailed Description
The password cannot be set because autodiscovery has not been completed yet.
Recommended Response Action
Wait until autodiscovery has completed and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6075

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve the device information because the entered device ID arg1 does not exist.
Arguments
  • arg1 = device ID
Detailed Description
The device information cannot be retrieved because the entered device ID does not exist.
Recommended Response Action
Enter a valid device ID and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6076

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve node information because no applicable nodes were found.
Detailed Description
Node information cannot be retrieved because no applicable nodes were found.
Recommended Response Action
Make sure that any nodes are in Full Switch mode and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6077

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve uplink port information because no applicable ports were found.
Detailed Description
Uplink port information cannot be retrieved because no applicable ports were found.
Recommended Response Action
Make sure ports are available and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6078

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve uplink port information because no ports were found.
Detailed Description
Uplink port information cannot be retrieved because no ports were found.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6079

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve device settings because device settings were not found for the device arg1.
Arguments
  • arg1 = device ID
Detailed Description
Device settings cannot be retrieved because device settings were not found for the device identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6080

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the management task on this device because the device is not onboarded.
Detailed Description
The management operation cannot be performed on this device because the device is not onboarded.
Recommended Response Action
Onboard the device from the All-Devices page and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6081

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis arg1 could not be added because it is already a member of the group arg2.
Arguments
  • arg1 = service tag
  • arg2 = group name
Detailed Description
The chassis could not be added because it is already a member of the group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6083

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or modify the Multi-chassis Management group.
Detailed Description
The Multi-chassis Management group cannot be created or modified.
Recommended Response Action
Make sure the entered group configuration is valid and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6084

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to join Multi-chassis Management group arg2 at arg3.
Arguments
  • arg1 = job
  • arg2 = arg2
  • arg3 = arg3
Detailed Description
The job is successfully created to join the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6085

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to join the Multi-chassis Management group arg1 at arg2.
Arguments
  • arg1 = group name
  • arg2 = IP address
Detailed Description
The device cannot be joined to the Multi-chassis Management group identified in the message.
Recommended Response Action
Make sure that the entered IP address is a group lead and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6086

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to leave the Multi-chassis Management group arg2 at arg3.
Arguments
  • arg1 = job ID
  • arg2 = group Name
  • arg3 = ip Address
Detailed Description
The job is successfully created to leave the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6087

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to leave the Multi-chassis Management group arg1 at arg2.
Arguments
  • arg1 = arg1
  • arg2 = arg2
Detailed Description
The device was unable to leave the Multi-chassis Management group.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6088

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to add the chassis arg2 to the Multi-chassis Management group arg3.
Arguments
  • arg1 = job
  • arg2 = chassis
  • arg3 = group
Detailed Description
The job is successfully created to add the chassis to the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6089

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the chassis arg1 to the Multi-chassis Management group arg2.
Arguments
  • arg1 = chassis
  • arg2 = group
Detailed Description
The chassis cannot be added to the Multi-chassis Management group identified in the message.
Recommended Response Action
Make sure that the group is available and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6090

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to remove the chassis arg2 from the Multi-chassis Management group arg3.
Arguments
  • arg1 = job
  • arg2 = chassis name
  • arg3 = group name
Detailed Description
The job is successfully created to remove the chassis from the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6092

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to create or modify Multi-chassis Management group arg2.
Arguments
  • arg1 = job
  • arg2 = group
Detailed Description
The Multi-chassis Management group identified in the message is successfully created or modified.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6093

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis arg1 is approved to join the Multi-chassis Management group arg2.
Arguments
  • arg1 = chassis
  • arg2 = group
Detailed Description
The chassis is approved to join the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6094

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis arg1 is denied from joining the Multi-chassis Management group arg2.
Arguments
  • arg1 = chassis
  • arg2 = group
Detailed Description
The chassis is denied from joining the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6095

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request to join the Multi-chassis Management group arg1 is approved.
Arguments
  • arg1 = group
Detailed Description
The request is approved to join the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6096

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the confirmation to join the Multi-chassis Management group.
Detailed Description
The confirmation to join the Multi-chassis Management group cannot be processed.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6097

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to delete the member chassis arg2 from the Multi-chassis Management group arg3.
Arguments
  • arg1 = job
  • arg2 = chassis
  • arg3 = group
Detailed Description
The job is successfully created to delete the member chassis from the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6098

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the job to delete the member chassis arg1 from the Multi-chassis Management group arg2.
Arguments
  • arg1 = chassis
  • arg2 = group
Detailed Description
The job to delete the member chassis from the Multi-chassis Management group identified in the message cannot be created.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6099

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Processed a request to leave the Multi-chassis Management group arg1.
Arguments
  • arg1 = group name
Detailed Description
Processed a request to leave the Multi-chassis Management group identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job arg1 is successfully created to delete the Multi-chassis Management group arg2.
Arguments
  • arg1 = job
  • arg2 = group
Detailed Description
The job to delete the Multi-chassis Management group identified in the message is successfully created.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the job to delete the Multi-chassis Management group arg1.
Arguments
  • arg1 = group
Detailed Description
The job to delete the Multi-chassis Management group identified in the message cannot be created.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create a job to add the chassis arg1 to the Multi Chassis Management group arg2.
Arguments
  • arg1 = chassis name
  • arg2 = group name
Detailed Description
Member chassis cannot be added to Multi Chassis Management group.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6105

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The member chassis arg1 was successfully added to the Multi Chassis Management group arg2.
Arguments
  • arg1 = chassis name
  • arg2 = group name
Detailed Description
The member chassis was successfully added to the Multi Chassis Management group.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6106

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the member chassis arg1 to the Multi Chassis Management group arg2.
Arguments
  • arg1 = chassis name
  • arg2 = group name
Detailed Description
The member chassis cannot be added to the Multi Chassis Management group.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6109

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 settings for the device with the identifier arg2 have been successfully updated.
Arguments
  • arg1 = setting type
  • arg2 = device identifier
Detailed Description
The settings for the device identified in the message are successfully updated.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6110

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the arg1 settings for the device with the identifier arg2 arg3.
Arguments
  • arg1 = setting type
  • arg2 = device identifier
  • arg3 = device message
Detailed Description
The settings for the device identified in the message cannot be updated.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6111

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 is successfully deleted.
Arguments
  • arg1 = device name
Detailed Description
The device identified in the message is successfully deleted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6112

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Storage assignment from the device arg1 is successful.
Arguments
  • arg1 = device ID
Detailed Description
Storage assignment from the device identified in the message is successful.
Recommended Response Action
No response action required.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6113

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign storage from the device arg1.
Arguments
  • arg1 = device ID
Detailed Description
Storage assignment from the device identified in the message is unsuccessful.
Recommended Response Action
Check the job execution history in the OpenManage Enterprise-Modular GUI for details on the error. Retry the operation after resolving this error.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Force Activation of SAS IOM device arg1 is successful.
Arguments
  • arg1 = device ID
Detailed Description
Force Activation of SAS IOM device identified in the message is successful.
Recommended Response Action
No response action required.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6115

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Clear Configuration operation on SAS IOM device arg1 is successful.
Arguments
  • arg1 = device ID
Detailed Description
The Clear Configuration operation on the SAS IOM device identified in the message is successful.
Recommended Response Action
No response action required.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6116

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Force Activation of SAS IOM device arg1 is unsuccessful.
Arguments
  • arg1 = device ID
Detailed Description
Force Activation of SAS IOM device identified in the message is unsuccessful.
Recommended Response Action
Check the job execution history in the OpenManage Enterprise-Modular GUI for details on the error. Retry the operation after resolving this error.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6117

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the Clear Configuration operation on the SAS IOM device arg1.
Arguments
  • arg1 = device ID
Detailed Description
The Clear Configuration operation cannot be completed on the SAS IOM device identified in the message.
Recommended Response Action
Check the job execution history in the OpenManage Enterprise-Modular GUI for details on the error. Retry the operation after resolving this error.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6118

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Extract logs from SAS IOM device arg1 successful.
Arguments
  • arg1 = device ID
Detailed Description
The Extract logs from SAS IOM device identified in the message is successful.
Recommended Response Action
No response action required.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6119

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Extract logs operation from SAS IOM device arg1 is unsuccessful.
Arguments
  • arg1 = device ID
Detailed Description
The Extract logs operation from SAS IOM device identified in the message is unsuccessful.
Recommended Response Action
Check the job execution history in the OpenManage Enterprise-Modular GUI for details on the error. Retry the operation after resolving this error.
Category
Storage (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6120

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the value entered in the field arg1 exceeds the maximum length of arg2 characters.
Arguments
  • arg1 = fieldName
  • arg2 = maxLength
Detailed Description
The operation cannot be completed because the value entered in the mentioned field exceeds the allowed character limit.
Recommended Response Action
Enter a value less than the specified character limit and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6121

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because information is not entered in mandatory field(s) arg1.
Arguments
  • arg1 = field name
Detailed Description
The request cannot be processed because information is not entered in mandatory field(s).
Recommended Response Action
Enter valid data in the mandatory field(s) and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6122

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the number of entries provided for attribute : arg1 exceeds the allowed limit of arg2.
Arguments
  • arg1 = fieldName
  • arg2 = entries
Detailed Description
The operation cannot be completed because the number of entries provided for the attribute identified in the message exceeds the allowed limit.
Recommended Response Action
Enter only the permitted number of entries in the payload.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6123

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the values entered for attribute arg1 has either duplicate or invalid IDs that do not exist.
Arguments
  • arg1 = fieldName
Detailed Description
The request cannot be processed because the values entered for attribute identified in the message has either duplicate or invalid IDs that do not exist.
Recommended Response Action
Enter valid and unique identifier values for the given attribute and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6124

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Successfully added to the Multi-chassis Management group arg1.
Arguments
  • arg1 = group
Detailed Description
Lead added this domain as a Member.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6125

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the native VLAN value is not required for Media Types such as FCoE, FC Gateway, and FC Direct Attach.
Detailed Description
The request cannot be processed because the native VLAN value is not required for Media Types such as FCoE, FC Gateway, and FC Direct Attach.
Recommended Response Action
Delete the native VLAN value and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6126

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or update the network because the entered Native VLAN value arg1 is not within the valid range of arg2-arg3 or arg4-arg5.
Arguments
  • arg1 = arg2
  • arg2 = arg3
  • arg3 = arg4
  • arg4 = arg5
  • arg5 = arg6
Detailed Description
The network cannot be created or updated because entered Native VLAN value is not with the range identified in the message.
Recommended Response Action
Enter a valid Native VLAN value and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6127

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the entered Native VLAN value arg1 is same as the VLAN range already contained by the network.
Arguments
  • arg1 = vlan
Detailed Description
The request cannot be processed because the entered Native VLAN value is same as the VLAN range already contained by the network.
Recommended Response Action
Enter a unique Native VLAN value and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6128

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the uplink for FC Media Type (FCoE, FC Gateway and Direct Attach), can accept only one FC capable network.
Detailed Description
The request cannot be processed because the uplink for FC Media Type (FCoE, FC Gateway and Direct Attach), can accept only one FC capable network.
Recommended Response Action
Enter only a FC capable network and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6132

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A new device is detected in the chassis.
Detailed Description
A new device is detected in the chassis.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6133

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A new device arg1 is added in slot number arg2 for chassis arg3.
Arguments
  • arg1 = device identifier
  • arg2 = device slot number
  • arg3 = chassis service tag
Detailed Description
A new device is successfully inserted in the chassis.
Recommended Response Action
No response action is required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6134

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A device arg1 is removed from slot number arg2 in chassis arg3.
Arguments
  • arg1 = device identifier
  • arg2 = slot number
  • arg3 = chassis service tag
Detailed Description
A device is removed from the chassis.
Recommended Response Action
No response action is required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6136

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request to join the Multi-chassis Management group arg1 is rejected.
Arguments
  • arg1 = group
Detailed Description
The request to join the Multi-chassis Management group identified in the message is rejected.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6137

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the uplink for FC Media Type (FCoE, FC Gateway, and Direct Attach) can accept port(s) only from the same IOM.
Detailed Description
The request cannot be processed because the uplink for FC Media Type (FCoE, FC Gateway, and Direct Attach) can accept port(s) only from the same IOM.
Recommended Response Action
Enter port(s) numbers that are from only the same IOM and then retry the operation. For more information see the OpenManageEnterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6138

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to communicate to the I/O Modules (IOMs) because either the IOMs are unavailable or not online.
Detailed Description
The I/O Modules (IOMs) cannot be communicated to because either the IOMs are unavailable or not online.
Recommended Response Action
Make sure that the IOMs are available and online in the system for use. For more information about IOMs, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6139

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the server profile, arg1, does not exist.
Arguments
  • arg1 = Server Profile Id
Detailed Description
The operation cannot be completed because the server profile identified in the message does not exist.
Recommended Response Action
Make sure that the following are correct and retry the operation: 1) The server profile entered is valid. 2) The server profile ID entered is valid.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6141

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to connect to the network share address because the network connection timed out.
Detailed Description
The network share address provided cannot be connected to because the network connection timed out.
Recommended Response Action
Enter a valid network share address and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6142

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Test Connection operation is successfully completed.
Detailed Description
The Test Connection operation is successfully completed.
Recommended Response Action
No response action is required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6143

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to access the network share file folder because the necessary privileges are unavailable.
Detailed Description
The network share file folder cannot be accessed because the necessary privileges are unavailable.
Recommended Response Action
Make sure necessary access rights and privileges are available and retry the operation. Contact your system administrator. For more information about the levels of user privileges, see the Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6144

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to access the network share file folder.
Detailed Description
The network share file folder cannot be accessed.
Recommended Response Action
Make sure a valid network share file folder and network share address is entered with a supported share type version, and retry the operation. If the issue persists, perform reset or restart as applicable to the product. See the product Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6145

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to access the network share file folder because of network issues.
Detailed Description
The network share file folder cannot be accessed because of network issues.
Recommended Response Action
Make sure that a correct file folder path is entered, and then retry the operation. For more information, see the Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6146

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the Test Connection operation because the operation timed out.
Detailed Description
The Test Connection operation cannot be completed because the operation timed out.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider. For more information, see the Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6147

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the Test Connection operation because the share file folder entered is a directory.
Detailed Description
The Test Connection operation cannot be completed because the share file folder entered is a directory.
Recommended Response Action
Enter a valid network share file folder path and retry the operation. For more information, see the Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6148

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to connect to the network share address because the network connection was refused.
Detailed Description
The network share address provided cannot be connected to because the network connection was refused.
Recommended Response Action
Enter a valid network share address and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6149

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to set the Service Tag of the device because it is already set.
Detailed Description
The Service Tag of the device cannot be set because it is already set.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6150

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update arg1 on the device: arg2.
Arguments
  • arg1 = operation name
  • arg2 = error message
Detailed Description
Unable to updated the operation identified in the message on the device.
Recommended Response Action
Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6151

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The leader chassis of the Multi-Chassis Management group does not have a backup chassis.
Detailed Description
No Backup has been assigned.
Recommended Response Action
Assign a member of the group as the backup chassis. For information about assigning a backup chassis, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6152

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Detected previous lead chassis arg1 online, transitioned it to member of the Multi-Chassis Management arg2.
Arguments
  • arg1 = service tag
  • arg2 = group
Detailed Description
Former Lead Chassis was detected and transitioned to Member role.
Recommended Response Action
None.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6153

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Detected previous lead chassis arg1 online, transitioned it to a standalone and out of the Multi-Chassis Management arg2.
Arguments
  • arg1 = service tag
  • arg2 = group
Detailed Description
Detected Former Lead and transitioned it as a standalone, out of the group.
Recommended Response Action
Unable to transition the old lead chassis to member of the Multi-Chassis Management, so removed it from the group. This transition may cause loss of fabric management functionality if any fabrics existed on the old lead chassis. Review fabric management and re-configure as needed.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6154

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Detected multiple lead chassis arg1 for the same Multi-Chassis Management arg2, unable to perform automatic recovery.
Arguments
  • arg1 = service tag
  • arg2 = group
Detailed Description
Detected Multiple Leader Chassis in Group, Unable to recover.
Recommended Response Action
Perform the following steps for each old lead chassis1) Disconnect the stacking cable from the chassis.2) Execute racadm racresetcfg -forceAfter the above 2 steps, the old lead chassis will be transitioned to a standalone chassis and does not interfere with the functions of the existing lead chassis.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6155

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Detected previous backup chassis arg1 online, transitioned it to member of the Multi-Chassis Management arg2.
Arguments
  • arg1 = service tag
  • arg2 = group
Detailed Description
Detected Former Backup Lead Chassis, and transitioned it to Member role.
Recommended Response Action
None.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6156

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Detected multiple backup chassis arg1 for the same Multi-Chassis Management arg2, unable to perform automatic recovery.
Arguments
  • arg1 = service tag
  • arg2 = group
Detailed Description
Detected Multiple Backup Leader Chassis; Unable to recover.
Recommended Response Action
Perform the following steps for each backup chassis1) Execute leave group operation, this removes the backup chassis from the group and deletes all configuration related to backup.2) If group membership is desired, execute join group operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6157

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request to update the server profile(s) is successfully submitted.
Detailed Description
The request to update the server profiles is successfully submitted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6158

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the server profile(s) because invalid parameters are entered.
Detailed Description
The server profiles cannot be updated because invalid parameters are entered.
Recommended Response Action
Enter valid update parameters and retry the operation. For information about updating server profiles, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6159

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request to update the server profile(s) by using a generic template is successfully submitted.
Detailed Description
The request to update the server profiles by using a generic template is successfully submitted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6160

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Update request, using generic template, for provided server profile(s) failed.
Detailed Description
The servers identified in the message could not be updated.
Recommended Response Action
Enter valid update parameters and retry the operation. For information about updating server profiles, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6161

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The append networks request for server profile(s) was successfully submitted.
Detailed Description
The append networks request for server profile(s) was successfully submitted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6162

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The append networks request for servers failed.
Detailed Description
The append networks request for servers failed.
Recommended Response Action
Enter valid update parameters and retry the operation. For information about appending server profiles to networks, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6163

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The delete networks request for server profile(s) was successfully submitted.
Detailed Description
The delete networks request for server profile(s) was successfully submitted.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6164

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The delete networks request for servers failed.
Detailed Description
The delete networks request for servers failed.
Recommended Response Action
Enter valid server update parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6165

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An internal device is successfully removed.
Detailed Description
An internal device is successfully removed.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6166

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request to create group because the chassis is a member of another group.
Detailed Description
The requested operation to create group cannot be processed because the chassis is already a member of another group.
Recommended Response Action
Execute leave operation on the chassis and retry the request to create new group.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6167

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A request is successfully submitted to update the untagged network settings of server profile(s).
Detailed Description
A request is successfully submitted to update the untagged network settings of server profile(s).
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6168

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to submit the request to update the untagged network settings of server profile(s).
Detailed Description
A request cannot be submitted to update the untagged network settings of server profile(s).
Recommended Response Action
Enter valid data about the server profiles, and then retry the operation. For more information about updating untagged network settings, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6172

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Device health has improved.
Detailed Description
Device Health Changed to OK.
Recommended Response Action
No response action is required.
Category
System Health (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6173

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Device health is unknown.
Detailed Description
The device health status has changed.
Recommended Response Action
Check the device subsystems for components that require immediate attention. For information about device health statuses, see the Online Help by clicking the help icon. Also see the Users Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6175

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Device health has deteriorated.
Detailed Description
The device health status has changed.
Recommended Response Action
Check the device subsystems for components that require immediate attention. For information about device health statuses, see the Online Help by clicking the help icon. Also see the Users Guide available on the support site.
Category
System Health (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6176

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to import the VLAN because the target device arg1 does not have any VLANs to import.
Arguments
  • arg1 = device Name
Detailed Description
The VLAN cannot be imported because the target device identified in the message does not have any VLANs to import.
Recommended Response Action
Make sure that the target device has VLANs, and then retry the operation. If VLANs do not exist, create VLANs on the target device.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6177

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the entered Service Tag of the new switch is invalid.
Detailed Description
The request cannot be processed because the entered Service Tag of the new switch is invalid.
Recommended Response Action
Enter a valid Service Tag of the switch that is already discovered by the OpenManage Enterprise-Modular.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6178

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The switch replacement request for the fabric arg1 is successfully submitted.
Arguments
  • arg1 = fabric Name
Detailed Description
The switch replacement request for the fabric identified in the message is successfully submitted.
Recommended Response Action
No response action is required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6179

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to replace the switch of fabric arg1 because arg2.
Arguments
  • arg1 = fabric Name
  • arg2 = error Message From IOM
Detailed Description
The switch of the fabric identified in the message cannot be replaced.
Recommended Response Action
Enter a valid Service Tag of both the old and new switch and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6180

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the request because the ScaleVLANProfile value provided is invalid.
Detailed Description
The request cannot be processed because the ScaleVLANProfile value provided is invalid.
Recommended Response Action
Enter a valid ScaleVLANProfile value (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6181

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the job to perform the arg1 opertion because of an internal error in the server.
Arguments
  • arg1 = operation name
Detailed Description
The job cannot be created to perform the operation identified in the message because of an internal error in the server.
Recommended Response Action
Wait for few minutes and retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6182

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request operation failed at fabric manger due to request timed out or connection failure.
Detailed Description
The Request operation failed at fabric manager.
Recommended Response Action
Please review the current status of the fabric, before retrying the operation. Because in case of request timeout fabric manager may potentially go ahead and perform the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6190

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the fabric arg1. arg2.
Arguments
  • arg1 = fabric
  • arg2 = message
Detailed Description
The fabric identified in the message could not be created.
Recommended Response Action
Enter valid fabric parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6191

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the fabric arg1. arg2.
Arguments
  • arg1 = fabric
  • arg2 = message
Detailed Description
The fabric identified in the message cannot be updated because invalid fabric parameters are entered.
Recommended Response Action
Enter valid fabric parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6192

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The deletion request for fabric arg1 failed. arg2.
Arguments
  • arg1 = fabric
  • arg2 = message
Detailed Description
The fabric identified in the message could not be deleted.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6193

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the uplink arg1 for fabric arg2. arg3.
Arguments
  • arg1 = uplink
  • arg2 = fabric
  • arg3 = message
Detailed Description
The uplink cannot not be created for the fabric identified in the message.
Recommended Response Action
Enter valid uplink parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6194

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the uplink arg1 for fabric arg2. arg3.
Arguments
  • arg1 = uplink
  • arg2 = fabric
  • arg3 = message
Detailed Description
The uplink cannot be updated for the fabric identified in the message.
Recommended Response Action
Enter valid uplink parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6195

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to delete the uplink arg1 for fabric arg2. arg3.
Arguments
  • arg1 = uplink
  • arg2 = fabric
  • arg3 = message
Detailed Description
The uplink cannot be deleted for the fabric identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6196

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the multicast networks for fabric arg1.
Arguments
  • arg1 = fabric
Detailed Description
The multicast networks updatefor the givenfabric is not successful.
Recommended Response Action
Enter valid mutlicast parameters and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6197

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Refresh inventory when fabric manager capability change for firmware update.
Detailed Description
Refresh inventory whenfabric manager capability change for firmware update.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6198

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Quick Deploy settings are applied on arg1.
Arguments
  • arg1 = servicetag
Detailed Description
When user reinserts a compute, if quick deploy settings are not applied and their is no profile attached to the slot, then with out creating quick deploy job settings will be applied to the device and this audit log message will be added.
Recommended Response Action
Quick deploy settings are applied to the device.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Quick Deploy settings operation failed for arg1.
Arguments
  • arg1 = servicetag
Detailed Description
Applying quick deploy settings failed to apply on device.
Recommended Response Action
Quick deploy settings operation failed.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6200

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Debug capability Invoked.
Detailed Description
User invoked debug capability.
Recommended Response Action
No response actionrequired.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6201

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
FSD Disabled.
Detailed Description
User disabled FSD.
Recommended Response Action
No response action required.
Category
Audit (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6504

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform arg1 because arg2.
Arguments
  • arg1 = operation
  • arg2 = reason
Detailed Description
The operation cannot becompleted because of the issue identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV6505

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The operation cannot be completed.
Detailed Description
Unable toperform share type testbecauseone or more task(s) using share is in progress.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7141

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Server NIC Bonding configuration operation for the server profile: arg1, because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Arguments
  • arg1 = field1
Detailed Description
The Server NIC Bonding configuration operation cannot be performed for the server identified in the message, because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7142

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Server NIC Bonding configuration operation for the server arg1, because the necessary bonding technology is not provided.
Arguments
  • arg1 = server Name
Detailed Description
The Server NIC Bonding configuration operation cannot be performed for the server identified in the message, because the necessary bonding technology is not provided.
Recommended Response Action
Provide the necessary bonding technology and NIC Bonded value, and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7143

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform onboarding as the connection to the target could not be created.
Detailed Description
Unable to perform onboarding as the connection to the target could not be created.
Recommended Response Action
Make sure that the device ready and available for onboarding, and then retry the operation. For more information, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7144

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1. But the Fabric OverrideLLDPConfiguration is not configured, because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Arguments
  • arg1 = arg1
Detailed Description
The Fabric OverrideLLDPConfiguration is not configured, because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Recommended Response Action
Please update the firmware version of the I/O Module running the Fabric Manager if necessary. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7145

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fabric creation request is submitted successfully. The OverrideLLDPConfiguration attribute is not provided in the payload, the Fabric LLDP configuration is set to Disabled by default.
Detailed Description
The Fabric LLDP configuration is disabled by default, in case the OverrideLLDPConfiguration attribute is not entered in the payload. Users needs to provide OverrideLLDPConfiguration to override the LLDP configuration.
Recommended Response Action
Please provide the OverrideLLDPConfiguration as Enabled in the Fabric update request, if the LLDP configuration needs to be overridden.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7146

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Fabric LLDP configuration operation on the fabric because the necessary OverrideLLDPConfiguration attribute entered in the Payload field is invalid.
Detailed Description
The Fabric LLDP configuration operation cannot be performed on the fabric because the OverrideLLDPConfiguration attribute entered in the Payload field is invalid.
Recommended Response Action
Enter a valid OverrideLLDPConfiguration attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7147

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Ethernet - No Spanning Tree uplink creation operation, because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Detailed Description
The Ethernet - No Spanning Tree uplink creation operation cannot be performed, because the firmware version of the I/O Module running the Fabric Manager does not support the creation feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7148

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to configure the fabric VLAN pass-through configuration mode on the fabric because the necessary "FabricVlanPassThroughMode" attribute is not entered in the "payload" field.
Detailed Description
The fabric VLAN pass-through configuration mode on the fabric cannot be configured because the necessary "FabricVlanPassThroughMode" attribute is not entered in the "payload" field.
Recommended Response Action
Enter a valid FabricVlanPassThroughMode attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7149

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to configure the fabric VLAN pass-through configuration mode on the fabric because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Detailed Description
The fabric VLAN pass-through configuration mode on the fabric cannot be configured because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7150

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to configure the Uplink Failure Detection mode on the uplink because the necessary UfdEnable attribute is not entered in the payload field.
Detailed Description
The Uplink Failure Detection mode on the uplink cannot be configured because the necessary UfdEnable attribute is not entered in the payload field.
Recommended Response Action
Enter the necessary UfdEnable attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7151

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to configure the Uplink Failure Detection mode on the uplink because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Detailed Description
The Uplink Failure Detection mode on the uplink cannot be configured because the firmware version of the I/O Module running the Fabric Manager does not support the configuration feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7152

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Fabric VLAN pass through mode configuration operation on the fabric because the necessary FabricVlanPassThroughMode attribute entered in the Payload field is invalid.
Detailed Description
The Fabric VLAN pass through mode configuration operation cannot be performed on the fabric because the FabricVlanPassThroughMode attribute entered in the Payload field is invalid.
Recommended Response Action
Enter a valid FabricVlanPassThroughMode attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7153

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Uplink Failure Detection configuration operation on the uplink because the necessary UfdEnable attribute entered in the Payload field is invalid.
Detailed Description
The Uplink Failure Detection configuration operation cannot be performed on the uplink because the necessary UfdEnable attribute is not entered in the payload field.
Recommended Response Action
Enter a valid UfdEnable attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7154

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fabric update is successful. The OverrideLLDPConfiguration attribute is not provided in the payload, so it preserves the previous value.
Detailed Description
The Fabric LLDP configuration is not updated, because the OverrideLLDPConfiguration attribute is not entered in the payload.
Recommended Response Action
Please update the Fabric with the OverrideLLDPConfiguration as Disabled or Enabled if necessary.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7155

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Request is submitted successfully. The AssignAllVLANsConfiguration attribute is not provided in the payload, the configuration is preserved or set to Disabled by default.
Detailed Description
The Assign All VLANs Configuration on the fabric cannot be configured because the necessary AssignAllVLANsConfiguration attribute is not entered in the payload field.
Recommended Response Action
Please provide the AssignAllVLANsConfiguration as Enabled in the Fabric update request, if the configuration needs to be overridden.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7156

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to configure the Assign All VLANs Configuration on the fabric because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Detailed Description
The Assign All VLANs Configuration on the fabric cannot be configured because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7157

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the Assign All VLANs Configuration on the fabric because the necessary AssignAllVLANsConfiguration attribute entered in the Payload field is invalid.
Detailed Description
The Assign All VLANs configuration on the fabric cannot be performed on the fabric because the AssignAllVLANsConfiguration attribute entered in the Payload field is invalid.
Recommended Response Action
Enter a valid AssignAllVLANsConfiguration attribute (enabled or disabled), and then retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV7158

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the arg1 operation on the fabric because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Arguments
  • arg1 = featureName
Detailed Description
The operation cannot be completed on the fabric because the firmware version of the I/O module running the fabric manager does not support the configuration feature.
Recommended Response Action
Update the firmware version of the I/O Module running the Fabric Manager and retry the operation. For information about the recommended I/O Module firmware versions, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV8500

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Successfully disabled Replication Chassis Settings on IOM Device.
Detailed Description
Replication of applicable chassis configurations settings to all supported IOMs has been disabled successfully.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV8501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Replication of Chassis Settings will be applied only when IOM Device arg1 is online.
Arguments
  • arg1 = device Name
Detailed Description
The operation to Replicate Chassis Settings failed as IOM is not online.
Recommended Response Action
Please try bring your IOM online. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV8502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 was not subscribed to the Redfish event during onboarding.
Arguments
  • arg1 = device_name
Detailed Description
The device was not subscribed to the Redfish event during onboarding.
Recommended Response Action
Enable alert reception from discovered devices during onboarding to subscribe to Redfish events.
Category
Audit (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
This device and several others has become non compliant after running compliance task:arg1.
Arguments
  • arg1 = task Name
Detailed Description
A device has become non compliant.
Recommended Response Action
Update the device or component firmware using a catalog or update package.
Category
Audit (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The mutlicast networks for fabric arg1 is successfully updated.
Arguments
  • arg1 = fabric
Detailed Description
The multicast networks is successfully updated for the providedfabric.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to attach the profile arg1 with the slot or device arg2 because: arg3.
Arguments
  • arg1 = profile Name
  • arg2 = Identifier
  • arg3 = Reason
Detailed Description
The profile cannot be attached with the slot or device as identified in the message because of the reasons indicated in the message.
Recommended Response Action
Review the reason and initiate necessary action.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to migrate the profile arg1 from the slot or device arg2 to the slot or device arg3 because: arg4.
Arguments
  • arg1 = profile Name
  • arg2 = Source Identifier
  • arg3 = Destination Identifier
  • arg4 = reason
Detailed Description
The profile cannot be migrated from the slot or device to the slot or device as identified in the message because of the reasons indicated in the message.
Recommended Response Action
Review the reason and initiate necessary action.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Network Controller group information is successfully updated.
Detailed Description
The Network Controller group information successfully updated.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to sync the settings of MCM member arg1 for the Setting IDs arg2.
Arguments
  • arg1 = member Name
  • arg2 = ID Names
Detailed Description
The settings of MCM member cannot by synced for the Settings IDs identified in the message.
Recommended Response Action
Check the logs for more details.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The MCM member arg1 settings are successfully applied to arg2.
Arguments
  • arg1 = member name 1
  • arg2 = name
Detailed Description
The MCM member settings are successfully applied as identified in the message.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9746

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to successfully complete the "Create" operation because the property name arg1 is not entered.
Arguments
  • arg1 = property Name
Detailed Description
The "Create" operation cannot be successfully completed because the property name is not entered.
Recommended Response Action
Enter a valid property name and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9765

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The OpenManage Enterprise-Modular appliance bundle download operation is in progress.
Detailed Description
The OpenManage Enterprise-Modular appliance bundle download operation is in progress.
Recommended Response Action
No response action is required.
Category
Miscellaneous (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9988

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Replication of Chassis Settings for arg1 was successfully submitted on the IOM Device arg2 with following error(s):arg3.
Arguments
  • arg1 = settingType
  • arg2 = deviceName
  • arg3 = errorMsg
Detailed Description
The operation to Replicate Chassis Settings failed. Retry the operation.
Recommended Response Action
The operation to Replicated Chassis Settings failed. Retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9989

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Replication of Chassis Settings for arg1 on IOM Device arg2 was successful.
Arguments
  • arg1 = settingType
  • arg2 = deviceName
Detailed Description
The operation to Replicate Chassis Settings is successful.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9990

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The operation to validate VLAN profile(s) is successful.
Detailed Description
The operation to validate VLAN profile(s) is successful.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9991

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The operation to validate VLAN profile(s) failed. Retry the operation.
Detailed Description
The operation to validate VLAN profile(s) failed. Retry the operation.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9992

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job created to import all valid VLAN profile(s) is successful.
Detailed Description
The job created to import all valid VLAN profile(s) is successful.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9993

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The export operation to retrieve VLAN profile(s) failed. Retry the operation.
Detailed Description
The export operation to retrieve VLAN profile(s) failed. Retry the operation.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9994

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The export operation to retrieve VLAN profile(s) is successful.
Detailed Description
The export operation to retrieve VLAN profile(s) is successful.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9995

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The job created to import all valid VLAN profile(s) failed. Retry the operation.
Detailed Description
The job created to import all valid VLAN profile(s) failed. Retry the operation.
Recommended Response Action
Retry the operation. If the issue persists, contact your system administrator.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9996

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to initiate replication of applicable chassis configuration settings to all supported IOMs.
Detailed Description
Unable to initiate replication of applicable chassis configuration settings to all supported IOMs.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9997

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Replication of applicable chassis configuration settings to all supported IOMs has been initiated successfully.
Detailed Description
Replication of applicable chassis configuration settings to all supported IOMs has been initiated successfully.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9998

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Date and time change operation has been initiated.
Detailed Description
Date and time change operation has been initiated.
Recommended Response Action
No response action required.
Category
Configuration (CDEV = Devices)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CDEV9999

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Reset to defaults is not supported on a lead chassis in the MCM group.
Detailed Description
The lead group properties cannot be reset.
Recommended Response Action
Dissolve the lead group and retry the operation.
Category
Configuration (CDEV = Devices)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\