PowerEdge Servers Error and Event Messages Reference Guide

PDF

CPWR—Power Configuration Event Messages

CPWR0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power Management settings is successfully saved.
Detailed Description
The Power Management settings is successfully saved.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to save the Power Management settings because of internal issues.
Detailed Description
The Power Management settings cannot be saved because of internal issues.
Recommended Response Action
Retry the operation. If the issue persists, contact your OpenManage Enterprise administrator.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The following power management job is unsuccessful. Job Name: arg1, Job Type: arg2, Job ID: arg3, Job Status: arg4, Invalid Input: arg5.
Arguments
  • arg1 = jobName
  • arg2 = jobType
  • arg3 = jobID
  • arg4 = jobStatus
  • arg5 = Attribute
Detailed Description
The power management job identified in the message is unsuccessful.
Recommended Response Action
Retry the operation. If the issue persists, contact your OpenManage Enterprise administrator.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The following power management job is successful. Job Name: arg1, Job Type: arg2, Job ID: arg3, Job Status: arg4.
Arguments
  • arg1 = jobName
  • arg2 = jobType
  • arg3 = jobID
  • arg4 = jobStatus
Detailed Description
The power management job identified in the message is successful.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The group arg1 is successfully added for monitoring the arg2.
Arguments
  • arg1 = group ID
  • arg2 = group Type
Detailed Description
The group is successfully added for monitoring the group type identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The group arg1 is successfully deleted from list of arg2 monitoring.
Arguments
  • arg1 = group ID
  • arg2 = group Type
Detailed Description
The group is successfully deleted from the group type identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power Management settings is successfully saved.
Detailed Description
The Power Management settings is successfully saved.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to save the Power Management settings because of internal issues.
Detailed Description
The Power Management settings cannot be saved because of internal issues.
Recommended Response Action
Retry the operation. If the issue persists, contact your OpenManage Enterprise administrator.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The following devices are not anymore monitored by the Power Manager application because the OpenManage Enterprise license has expired: arg1.
Arguments
  • arg1 = device Names
Detailed Description
The devices identified in the message are not anymore monitored by the Power Manager application because OpenManage Enterprise the license has expired.
Recommended Response Action
To continue monitoring the devices, procure a valid OpenManage Enterprise license. For license information, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the specified group because the number of groups monitored for power management in the dashboard is more than three.
Detailed Description
The specified groups cannot be added because the number of groups monitored for power management in the dashboard is more than three.
Recommended Response Action
Make sure that the number of groups is less than three, and then retry the operation. To reduce the number of groups, remove it from the existing list. To set the group number, do the following: 1) In OpenManage Enterprise, click Add Groups. In the Add group(s) to dashboard dialog box, in the Selected group(s) section, select the group and click the remove symbol. 2) By using the REST API command, enter the group ID and run the command.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The properties of group arg1 for power management and monitoring are successfully updated.
Arguments
  • arg1 = groupNames
Detailed Description
The properties of the groups identified in the message are successfully updated for power management and monitoring.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The group membership properties of the following groups are successfully updated: arg1.
Arguments
  • arg1 = groups names
Detailed Description
The group membership properties of the following groups are successfully updated as identified in the message.
Recommended Response Action
For optimized power performance, it is recommended that you re-evaluate the power policies applied to these groups.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 of the group arg2 is violated because of the devices added to the group.
Arguments
  • arg1 = policy name
  • arg2 = group name
Detailed Description
The power policy of the group identified in the message is violated because of the devices added to the group.
Recommended Response Action
Reevaluate the power policy based on the newly added devices, and update the power cap value, if necessary.
Category
System Health (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The violation on the power policy arg1 of the group arg2 is now rectified.
Arguments
  • arg1 = policy name
  • arg2 = group name
Detailed Description
The violation on the power policy of the group identified is now rectified.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or modify the power policy arg1 because a power policy already exists with the same name.
Arguments
  • arg1 = Power Policy Name
Detailed Description
The power policy cannot be created or updated because a power policy already exists with the same name.
Recommended Response Action
Enter a unique power policy name and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create policy because some of the target devices do not have capability arg1.
Arguments
  • arg1 = CapabilityType
Detailed Description
Policy cannot be created because some of the target devices do not have capability as identified in the message.
Recommended Response Action
Make sure that all the target devices have the required capability and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the power policy because some of the target devices are not part of the group arg1.
Arguments
  • arg1 = groupName
Detailed Description
The power policy cannot be created because some of the target devices are not part of the group identified in the message.
Recommended Response Action
Enter a device name that belong to the group, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the entity arg1 is currently not monitored and managed for power.
Arguments
  • arg1 = entity ID
Detailed Description
The operation cannot be completed because the entity identified in the message is not monitored and managed for power.
Recommended Response Action
Ensure that the specified entity is monitored and managed for power and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power Cap value arg1 is successfully applied on arg2.
Arguments
  • arg1 = power cap value
  • arg2 = target name
Detailed Description
The Power Cap value is successfully applied on the target identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to apply the Power Cap value arg1 on arg2 because the device is either unreachable or does not have the necessary license or the supplied power cap value is not applicable for the device.
Arguments
  • arg1 = power cap value
  • arg2 = target name
Detailed Description
The Power Cap value cannot be applied on the device identified in the message because the device is either unreachable or does not have the necessary license or the supplied power cap value is not applicable for the device.
Recommended Response Action
Make sure that the target is reachable and has the required license and the power cap value is within supported range,and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power Cap feature is disabled on the target arg1.
Arguments
  • arg1 = target device name
Detailed Description
The Power Cap value is disabled on the target identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to disable the power cap value on the device arg1 because it is unreachable.
Arguments
  • arg1 = target device name
Detailed Description
The power cap value cannot be disabled on the device identified in the message because it is unreachable.
Recommended Response Action
Make sure that the target is reachable, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0023

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to enable the Emergency Power Reduction feature on the target arg1 because the feature is already enabled on the target.
Arguments
  • arg1 = target name
Detailed Description
The Emergency Power Reduction feature on the target identified in the message cannot be enabled because the feature is already enabled on the target.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to enable the Emergency Power Reduction feature because target devices are unavailable in the group.
Detailed Description
The Emergency Power Reduction feature cannot be enabled because target devices are unavailable in the group.
Recommended Response Action
Ensure that valid target devices are available in the group for enabling the Emergency Power Reduction feature, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0025

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Emergency Power Reduction feature is enabled on the target arg1.
Arguments
  • arg1 = target name
Detailed Description
The Emergency Power Reduction feature is enabled on the target identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0026

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to enable the Emergency Power Reduction feature on the target arg1 because the device is either unreachable or does not have necessary license.
Arguments
  • arg1 = target name
Detailed Description
The Emergency Power Reduction feature cannot be enabled on the target because the device is either unreachable or does not have necessary license.
Recommended Response Action
Make sure that the target is reachable and has the required license, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0027

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Emergency Power Reduction feature is successfully disabled on the target arg1.
Arguments
  • arg1 = target name
Detailed Description
The Emergency Power Reduction feature is successfully disabled on the target identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to disable Emergency Power Reduction on the device arg1 because it is unreachable.
Arguments
  • arg1 = target device name
Detailed Description
The Emergency Power Reduction feature cannot be disabled on the device identified in the message because it is unreachable.
Recommended Response Action
Ensure that the target device is reachable and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to remove or disassociate devices or groups from power management and monitoring because the Emergency Power Reduction feature is active on arg1.
Arguments
  • arg1 = entityType
Detailed Description
The devices or groups cannot be removed or disassociated from power management and monitoring because the Emergency Power Reduction feature is active on the entity identified in the message.
Recommended Response Action
Disassociate or disable all the Emergency Power Reduction features, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 are successfully arg2 in the Power Monitoring list.
Arguments
  • arg1 = Entity Type
  • arg2 = task Name
Detailed Description
The devices of groups identified in the message are successfully updated in the Power Monitoring list.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to arg1 the arg2 for power management and monitoring because arg3.
Arguments
  • arg1 = action
  • arg2 = entityType
  • arg3 = reason
Detailed Description
The devices identified in the message cannot be added for power management and monitoring because a valid license is unavailable.
Recommended Response Action
Retry the operation by using valid device IDs.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 is successfully deleted.
Arguments
  • arg1 = policy names
Detailed Description
The power policy identified in the message is successfully deleted.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 is disabled.
Arguments
  • arg1 = policy names
Detailed Description
The power policy identified in the message is disabled.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 is successfully created.
Arguments
  • arg1 = policy names
Detailed Description
The power policy identified in the message is successfully created.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 is successfully modified.
Arguments
  • arg1 = policy names
Detailed Description
The power policy identified in the message is successfully modified.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power policy arg1 is successfully enabled.
Arguments
  • arg1 = policy names
Detailed Description
The power policy identified in the message is successfully enabled.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 and other devices are no longer monitored and managed for power because the OpenManage Enterprise license has expired.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message and other devices are no longer monitored and managed for power because the OpenManage Enterprise license has expired.
Recommended Response Action
Purchase a valid OpenManage Enterprise license, deploy, and successfully monitor the devices. For information about OpenManage license, see the OpenManage Enterprise Users Guide available on the support site.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0038

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The current frequency for gathering power-related metric is set to arg1 minutes because more than arg2 devices are added for power management and monitoring.
Arguments
  • arg1 = interval
  • arg2 = device count
Detailed Description
The power-related metric collection frequency is configured to 15 minutes due to the addition of over 1,000 devices for power management and monitoring. Similarly, for over 8,000 devices, it is configured to 30 minutes. The supported collection intervals include 5, 15, and 30 minutes.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0039

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 are successfully arg2 from the Power Monitoring list.
Arguments
  • arg1 = Entity Type
  • arg2 = task Name
Detailed Description
The devices or groups identified in the message are successfully removed from the Power Monitoring list.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unmonitored device arg1 is successfully arg2.
Arguments
  • arg1 = device Name
  • arg2 = action Name
Detailed Description
An operation is successfully completed on the unmonitored device identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0041

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or edit the device because the device name entered already exists.
Detailed Description
The device cannot be created or edited because the device name entered already exists.
Recommended Response Action
Enter a unique device name and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0042

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create or edit the device because the device identifier name entered already exists.
Detailed Description
The device cannot be created or edited because the device identifier name entered already exists.
Recommended Response Action
Enter a unique device identifier name and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0043

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to disassociate devices from power management and monitoring because the devices arg1 are already associated with groups.
Arguments
  • arg1 = deviceNames
Detailed Description
The device cannot be disassociated from power management and monitoring because the devices identified in the message are already associated with groups.
Recommended Response Action
By using OpenManage Enterprise, remove the devices from groups, and then retry the operation. After the devices are removed, the devices status is automatically updated.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0044

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to place the device arg1 because the device size (U) is not conforming to the defined standards.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message cannot be placed because the device size (U) is not conforming to the defined standards.
Recommended Response Action
Make sure that the device size (U) is correct and retry the operation. For information about compatible device types, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0046

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move the device arg1 to the space because the device arg2 is occupying the space.
Arguments
  • arg1 = device Name
  • arg2 = target Device Name
Detailed Description
The device identified in the message cannot be moved in the rack because some other device is occupying the space.
Recommended Response Action
Ensure that there is enough consecutive unoccupied slots in the Rack for the device and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0047

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature of the group arg1 has exceeded the threshold temperature set by the temperature triggered policy arg2.
Arguments
  • arg1 = group Name
  • arg2 = policy Name
Detailed Description
The temperature of the group has exceeded the threshold temperature set by the temperature triggered policy identified in the message.
Recommended Response Action
Make sure that the cooling infrastructure is operational. For more information about the cooling system, see the respective hardware documentation of the device in the group.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0048

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The issue of temperature of the group arg1, exceeding the threshold temperature set by the temperature triggered policy arg2, is now resolved.
Arguments
  • arg1 = group Name
  • arg2 = policy Name
Detailed Description
The issue of temperature of the group, exceeding the threshold temperature set by the temperature triggered policy, is successfully resolved.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0049

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Emergency Power Reduction (EPR) cannot be enabled on the group arg1 because the member group devices are not supported for the operation, cannot be accessed, do not have necessary license, or EPR is already enabled.
Arguments
  • arg1 = groupName
Detailed Description
The Emergency Power Reduction feature cannot be enabled on the group identified in the message the member group devices are not supported for the operation, cannot be accessed, do not have necessary license, or EPR is already enabled.
Recommended Response Action
Make sure that the member devices in the group are accessible, have necessary license, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0050

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Emergency Power Reduction feature is successfully enabled on the group arg1 by using the temperature triggered policy arg2.
Arguments
  • arg1 = group Name
  • arg2 = policy Name
Detailed Description
The Emergency Power Reduction feature is successfully enabled on the group by using the temperature triggered policy identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0051

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unmonitored device arg1 is successfully created.
Arguments
  • arg1 = deviceName
Detailed Description
The unmonitored device identified in the message is successfully created.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0052

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unmonitored device arg1 is successfully deleted.
Arguments
  • arg1 = deviceName
Detailed Description
The unmonitored device identified in the message is successfully deleted.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0053

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unmonitored device arg1 is successfully modified.
Arguments
  • arg1 = device Names
Detailed Description
The unmonitored device identified in the message is successfully modified.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0054

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the temperature-triggered policy because a similar policy already exists on the group arg1.
Arguments
  • arg1 = group Name
Detailed Description
The temperature-triggered policy cannot be created because a similar policy already exists on the group identified in the message.
Recommended Response Action
Do one of the following: 1) Instead of creating a new policy, update the existing policy with the required temperature threshold value. 2) Delete the current temperature-triggered policy, and then create a new policy.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0055

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the temperature-triggered policy because the group arg1 is either empty or does not contain any devices that have the required license.
Arguments
  • arg1 = group Name
Detailed Description
The temperature-triggered policy cannot be created because the group name entered is either empty or does not contain any devices that have the required license.
Recommended Response Action
Make sure that the group contains devices having necessary license, and then retry the operation. Use GUI or REST API for adding devices to the group.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0056

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Emergency Power Reduction feature, with the ID arg1, cannot be manually disabled because it is applied by a temperature-triggered policy.
Arguments
  • arg1 = EPR Policy ID
Detailed Description
The Emergency Power Reduction feature, with the ID identified in the message, cannot be manually disabled because it is applied by a temperature-triggered policy. The feature will be automatically disabled when the temperature of the target group is less than the specified threshold value.
Recommended Response Action
Make sure that the cooling infrastructure is functional and the temperature-triggered policy is set to the required temperature threshold value.
Category
System Health (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0057

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature-triggered policy arg1 is successfully created.
Arguments
  • arg1 = policy name
Detailed Description
The temperature-triggered policy identified in the message is successfully created.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0058

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature-triggered policy arg1 is successfully modified.
Arguments
  • arg1 = policy name
Detailed Description
The temperature-triggered policy identified in the message is successfully modified.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0059

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature-triggered policy arg1 is successfully deleted.
Arguments
  • arg1 = policy name
Detailed Description
The temperature-triggered policy identified in the message is successfully deleted.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0060

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature-triggered policy arg1 is successfully enabled.
Arguments
  • arg1 = policy name
Detailed Description
The temperature-triggered policy identified in the message is successfully enabled.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0061

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The temperature-triggered policy arg1 is successfully disabled.
Arguments
  • arg1 = policy name
Detailed Description
The temperature-triggered policy identified in the message is successfully disabled.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0062

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 policy and other policies are successfully enabled for power management and monitoring.
Arguments
  • arg1 = policyName
Detailed Description
The policy identified in the message and other policies are successfully enabled for power management and monitoring. For more information, see the Policies page in the Power Management feature.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0063

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 policy and other policies are successfully disabled for power management and monitoring.
Arguments
  • arg1 = policyName
Detailed Description
The policy identified in the message and other policies are successfully disabled for power management and monitoring. For more information, see the Policies page in the Power Management feature.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0064

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Emergency Power Reduction feature that was earlier enabled on the arg1 group, by using the temperature-triggered policy arg2, is now automatically disabled.
Arguments
  • arg1 = group name
  • arg2 = policy name
Detailed Description
The Emergency Power Reduction feature that was earlier enabled on the group, by using the temperature-triggered policy identified in the message, is now automatically disabled. The feature is disabled because one or more of the following reasons: 1) The issue of temperature of the group, exceeding the threshold temperature set by the temperature-triggered policy, is successfully resolved. 2) The temperature-triggered policy is disabled or deleted.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0065

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power consumed by the arg1 group is arg2 which has exceeded the power capacity arg3 allocated by the user for the group.
Arguments
  • arg1 = group Name
  • arg2 = power Consumption
  • arg3 = power Allocation
Detailed Description
Power consumed by the group identified in the message has exceeded the power allocated by the user for the group.
Recommended Response Action
Make sure that sufficient Power Supply Units (PSUs) are available. If necessary, update the power allocated for the group.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0066

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power consumed by the arg1 group, which had exceeded the power capacity arg2 allocated by the user for the group, is now within the set limit.
Arguments
  • arg1 = group Name
  • arg2 = power Allocation
Detailed Description
Power consumed by the group, which had exceeded the allocated power capacity, is now within the user allocated limit as identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0067

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the physical group because multiple group tag names are entered.
Detailed Description
The physical group cannot be created because multiple group tag names are entered.
Recommended Response Action
Enter only one tag name and retry the operation. For information about creating physical groups, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0068

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the PHYSICAL_HIERARCHY_ROOT tag to the group.
Detailed Description
The PHYSICAL_HIERARCHY_ROOT tag cannot be assigned to the group.
Recommended Response Action
Enter a valid tag name and retry the operation. For information about tags, see the OpenManage Enterprise - Power Manager Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0069

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the physical group because the group tag name is not entered.
Detailed Description
The physical group cannot be created because the group tag name is not entered.
Recommended Response Action
Enter a valid tag name and retry the operation. For information about creating physical groups, see the OpenManage Enterprise - Power Manager Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0070

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the physical group because the power and space capacity attributes are not entered.
Detailed Description
The physical group cannot be created because the power and space capacity attributes are not entered.
Recommended Response Action
Enter a valid power and space capacity attributes in the payload and retry the operation. For information about creating physical groups, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0071

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to create the physical group because the arg1 attribute is non-editable.
Arguments
  • arg1 = attributeName
Detailed Description
The physical group cannot be created because the attribute is non-editable.
Recommended Response Action
Enter valid editable attribute in the payload and retry the operation. For information about creating physical groups, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0072

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the rack space capacity because the slot arg1 is occupied.
Arguments
  • arg1 = slot number
Detailed Description
The rack space capacity cannot be updated because the slot identified in the message is occupied by a device.
Recommended Response Action
Rearrange or remove the device to vacate slots and retry the operation. For information about updating rack space capacity, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0073

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the Emergency Power Reduction (EPR) feature is enabled on the group arg1.
Arguments
  • arg1 = groupName
Detailed Description
The operation cannot be completed because the Emergency Power Reduction (EPR) feature is enabled on the group identified in the message.
Recommended Response Action
Disable the Emergency Power Reduction (EPR) feature on the group, and then retry the operation. For information about disabling the EPR feature, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0074

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the device IDs and slot numbers must be unique.
Detailed Description
The operation cannot be completed because the device IDs and slot numbers must be unique.
Recommended Response Action
Enter unique values for device IDs and slot numbers and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0075

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because the group ID entered is not of "Rack" type.
Detailed Description
The operation cannot be completed because the group ID entered is not of "Rack" type.
Recommended Response Action
Enter a group ID of "Rack" type, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0076

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to accommodate the arg1 device in the rack because consecutive empty slots are unavailable in the rack.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message cannot be accommodated because consecutive empty slots are unavailable in the rack.
Recommended Response Action
Make sure that the necessary consecutive slots are available in the rack, and then retry the operation. For information about rack management, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0077

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device arg1 to the rack because the device is not rack-mountable.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message cannot be added to the rack because the device is not rack-mountable.
Recommended Response Action
Enter valid rack-mountable device ID in the payload, and then retry the operation. For information about valid rack-mountable devices, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0078

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the arg1 device to rack because the device is already associated with another rack.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message cannot be added to the rack because the device is already associated with another rack.
Recommended Response Action
Make sure that the device is not associated with any other rack, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0079

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to virtually place the device in the rack because the U-size information of the device is unavailable.
Detailed Description
The device cannot be virtually placed because the U-size information of the device is unavailable.
Recommended Response Action
Make sure device U size is available and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0080

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device to the rack because the Emergency Power Reduction (EPR) feature is currently enabled on the group arg1.
Arguments
  • arg1 = target Rack
Detailed Description
The device cannot be added to the rack because the Emergency Power Reduction (EPR) feature is currently enabled on the group identified in the message.
Recommended Response Action
Disable the Emergency Power Reduction (EPR) feature on the group from Power Management page, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0081

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to remove the device from the group because the device is not associated with the group.
Detailed Description
The device cannot be removed from the group because the device is not associated with the group.
Recommended Response Action
Make sure that the device is a part of the group, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0082

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move the device within the rack because the device is not associated with the rack.
Detailed Description
The device cannot be moved within the rack because the device is not associated with the rack.
Recommended Response Action
Make sure that the device is a part of the rack, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0083

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to explicitly add the arg1 physical group to the monitored list, because by default, the physical group is a part of the list of monitored groups.
Arguments
  • arg1 = groupName
Detailed Description
The physical group identified in the message cannot be explicitly added to the monitored list, because by default, the physical group is a part of the list of monitored groups.
Recommended Response Action
Enter valid data in the field and retry the operation. For information about valid data permitted in a field, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0084

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to explicitly remove the arg1 physical group from the monitored list, because by default, the physical group is a part of the list of monitored groups.
Arguments
  • arg1 = groupName
Detailed Description
The physical group identified in the message cannot be explicitly removed from the list of monitored group list, because by default, the physical group is a part of the list of monitored groups.
Recommended Response Action
Log into OpenManage Enterprise, and then delete the physical group. This action removes the physical group from the list of groups monitored using Power Management.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0085

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the size of the device arg1 because the device is placed in a rack that does not have slots to accommodate the size of the installed device.
Arguments
  • arg1 = deviceName
Detailed Description
Size of the device identified in the message cannot be updated because the device is placed in a rack that does not have slots to accommodate the size of the installed device.
Recommended Response Action
Make sure that the device is of recommended size that the rack can hold. For information about compatible device sizes, see the Rack Installation Guide of the respective device available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0086

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device to the rack because empty slots are unavailable in the rack.
Detailed Description
The device cannot be added to the rack because empty slots are unavailable in the rack.
Recommended Response Action
Make sure that the rack has empty slots of compatible device size, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0087

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device arg1 and other devices to the rack because the devices are not rack-mountable.
Arguments
  • arg1 = deviceName
Detailed Description
The device identified in the message and other devices cannot be added to the rack because the devices are not rack-mountable.
Recommended Response Action
Enter valid rack-mountable device IDs in the payload, and then retry the operation. For information about valid rack-mountable devices, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0088

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 information is successfully updated for power management and monitoring.
Arguments
  • arg1 = deviceName
Detailed Description
The information of the device identified in the message is successfully updated for power management and monitoring.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0089

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 information and other devices are successfully updated for power management and monitoring.
Arguments
  • arg1 = deviceName
Detailed Description
The information of the device identified in the message and other devices are successfully updated for power management and monitoring.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0090

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because data entered in the field arg1 is invalid.
Arguments
  • arg1 = field
Detailed Description
The operation cannot be completed because invalid data is entered in the field identified in the message.
Recommended Response Action
Enter valid data in the field and retry the operation. For information about valid data permitted in a field, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0091

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device to the physical group arg1 because devices can be added only using the OpenManage Enterprise API.
Arguments
  • arg1 = groupID
Detailed Description
The device cannot be added to the physical group identified in the message because devices can be added only using the OpenManage Enterprise API.
Recommended Response Action
Add the device to the physical group only by using the the OpenManage Enterprise API. For more information, see the OpenManage Enterprise API Guide available on the developer portal.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0092

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to remove the device from the physical group arg1 because devices can be removed only using the OpenManage Enterprise API.
Arguments
  • arg1 = groupID
Detailed Description
The device cannot be removed from the physical group identified in the message because devices can be added only using the OpenManage Enterprise API.
Recommended Response Action
Remove the device from the physical group only by using the OpenManage Enterprise API. For more information, see the OpenManage Enterprise API Guide available on the developer portal.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0093

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One or more devices are successfully added to the group arg1.
Arguments
  • arg1 = rack Name
Detailed Description
One or more devices are successfully added to the group identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0094

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The slot information, about one or more devices in the rack arg1, is successfully updated.
Arguments
  • arg1 = rack Name
Detailed Description
The slot information, about one or more devices in the rack identified in the message, is successfully updated.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0095

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One or more devices are successfully removed from the group arg1.
Arguments
  • arg1 = rack Name
Detailed Description
One or more devices are successfully removed from the group identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0096

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device arg1, or other devices to the group arg2 because: 1) Device ID is not valid. 2) Device is not rack-mountable. 3) Device is already added to a group. 4) Size details of the device does not exist or is invalid.
Arguments
  • arg1 = device Name
  • arg2 = rack Name
Detailed Description
One or more devices cannot be added to the group identified in the message because: 1) Device ID is not valid. 2) Device is not rack-mountable. 3) Device is already added to a group. 4) Size details of the device does not exist or is invalid.
Recommended Response Action
Make sure that the device ID is valid and have valid size information associated to them, and then retry the operation. For information about valid rack-mountable devices, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0097

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update size of one or more devices arg1 because they are not rack-mountable.
Arguments
  • arg1 = device IDs
Detailed Description
Unable to update size of one or more devices identified in the message because they are not rack-mountable.
Recommended Response Action
Ensure that the specified entity is monitored and managed for power and retry the operation.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0098

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the outlet arg1 to the device arg2 because the device ID entered does not belong to a Power Distribution Unit (PDU).
Arguments
  • arg1 = outletNum
  • arg2 = deviceID
Detailed Description
The outlet to the device identified in the message cannot be assigned because the device ID entered does not belong to a Power Distribution Unit (PDU).
Recommended Response Action
Enter a valid Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0099

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the outlet arg1 to the device arg2 because the Power Distribution Unit (PDU) device ID entered is invalid.
Arguments
  • arg1 = outletNum
  • arg2 = deviceID
Detailed Description
The outlet to the device identified in the message cannot be assigned because the Power Distribution Unit (PDU) device ID entered is invalid.
Recommended Response Action
Enter a valid Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0100

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the outlet arg1 to the device arg2 because the Power Distribution Unit (PDU) outlet is already associated to another device.
Arguments
  • arg1 = outletNum
  • arg2 = deviceID or deviceName
Detailed Description
The outlet to the device identified in the message cannot be assigned because the Power Distribution Unit (PDU) outlet is already associated to another device.
Recommended Response Action
Enter a valid and free (unoccupied) outlet number and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the outlet arg1 to the device arg2 because the Power Distribution Unit (PDU) and the device to be associated with the outlet is not in the same group.
Arguments
  • arg1 = outletNum
  • arg2 = deviceID
Detailed Description
The outlet to the device identified in the message cannot be assigned because the Power Distribution Unit (PDU) and the device to be associated with the outlet is not in the same group.
Recommended Response Action
Make sure that the device and the Power Distribution Unit (PDU) are from the same group, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the outlet arg1 to the device arg2 because the Power Distribution Unit (PDU) and the device to be associated with the outlet does not have the minimum required Power Supply Units (PSUs).
Arguments
  • arg1 = outletNum
  • arg2 = deviceID
Detailed Description
DevicesPSUs are already occupied so cannot assign outlet to device.
Recommended Response Action
Devices PSU is already occupied by PDU outlet, Clear the existing assignment using REST API /api/PowerService/PowerDevices/Actions/PowerDevices.DissociateDevices and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0103

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to disassociate the device from the Power Distribution Unit (PDU) because the device ID entered does not belong to a Power Distribution Unit (PDU).
Detailed Description
The outlet to the device identified in the message cannot be disassociated from the PDU because the device ID entered does not belong to a Power Distribution Unit (PDU).
Recommended Response Action
Enter a valid Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to disassociate the device from the Power Distribution Unit (PDU) because the PDU is not associated with any rack.
Detailed Description
The outlet to the device identified in the message cannot be disassociated from the PDU because the PDU is not associated with any rack.
Recommended Response Action
Enter a valid Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0105

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to clear the Power Distribution Unit (PDU) outlet arg1 because the PDU outlet is not assigned to any device.
Arguments
  • arg1 = outletNum
Detailed Description
The outlet identified in the message cannot be cleared because the Power Distribution Unit (PDU) outlet is not assigned to any device.
Recommended Response Action
Enter a valid occupied Power Distribution Unit (PDU) outlet and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0106

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign the Power Distribution Unit (PDU) arg1 to the rack because the PDU can be assigned to only one rack at any given time.
Arguments
  • arg1 = deviceID
Detailed Description
The Power Distribution Unit (PDU) device ID identified in the message cannot be assigned to rack because the PDU can be assigned to only one rack at any given time.
Recommended Response Action
Enter a valid unassigned Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0107

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to associate the Power Distribution Unit (PDU) arg1 to the rack because the PDU cannot be placed in the rack slot.
Arguments
  • arg1 = deviceID
Detailed Description
The Power Distribution Unit (PDU) cannot associated to the rack because the PDU cannot be placed in the rack slot.
Recommended Response Action
Enter a valid value(zero or null) for the rack slot and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0108

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to assign Power Distribution Unit (PDU) arg1 to rack because PDU is already associated with given rack.
Arguments
  • arg1 = deviceID
Detailed Description
The Power Distribution Unit (PDU) device identified in the message cannot be associated to rack because the PDU is already associated to rack.
Recommended Response Action
Enter a valid free (Unassociated) Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0109

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve Power Distribution Unit (PDU) outlet assignment details because the PDU with given ID does not exist.
Detailed Description
The Power Distribution Unit (PDU) outlet assignment details cannot be retrieved because the PDU with the given ID does not exist.
Recommended Response Action
Enter a valid existing Power Distribution Unit (PDU) device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0110

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update details of the device arg1 because device PSU count is lesser than the total Power Distribution Unit (PDU) outlet assigned to it.
Arguments
  • arg1 = deviceID
Detailed Description
The operation cannot be completed because the device identified in the message has more Power Distribution Unit (PDU) outlet assignment than the PSU count.
Recommended Response Action
Make sure that PSU count of the device is same or more than the total Power Distribution Unit (PDU) outlet assigned to it.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0111

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move the device arg1 to other rack because device is assigned to Power Distribution Unit (PDU) outlet.
Arguments
  • arg1 = deviceID
Detailed Description
The operation cannot be completed because device identified in the message is assigned to Power Distribution Unit (PDU) outlet.
Recommended Response Action
Clear the outlet assignments of the device identified in the message and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0112

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update details of the device arg1 because device PSU count cannot be more than 8.
Arguments
  • arg1 = deviceID
Detailed Description
Data of the device identified in the message cannot be updated because the device PSU count is more than the recommended threshold value of 1-8.
Recommended Response Action
Make sure that the device PSU count is between 1 to 8 and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0113

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One or more Power Distribution Unit (PDU) outlets are successfully updated.
Detailed Description
One or more Power Distribution Unit (PDU) outlets are successfully updated.
Recommended Response Action
Noresponse action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the Virtual Machine (VM) arg1 to virtual machine group because the server in which the VM exists is not monitored and managed for power.
Arguments
  • arg1 = vmName
Detailed Description
Virtual Machine (VM) identified in the message cannot be added to Virtual machine group because the server in which the VM exists is not monitored and managed for power.
Recommended Response Action
Make sure that the server in which the Virtual Machine (VM) exists is part of the Power Management motoring list and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0115

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add Virtual Machine (VM) arg1 to Virtual machine group because the VM already exist in the Virtual machine group.
Arguments
  • arg1 = vmName
Detailed Description
The Virtual Machine (VM) identified in the message cannot be added to the VM group because a VM already exists in the VM group.
Recommended Response Action
Make sure that the Virtual Machine (VM) to be added is not exist in the Virtual Machine Group and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0116

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add Virtual Machine(s) (VM) to Virtual Machine Group because the value entered for Virtual Machine Group is invalid.
Detailed Description
The operation cannot be completed because the value entered for Virtual Machine Group is invalid.
Recommended Response Action
Enter valid existing Virtual Machine Group ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0117

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to remove the virtual machine arg1 from the Virtual Machine Group because the entered VM ID is not associated to the VM group.
Arguments
  • arg1 = VMname
Detailed Description
The Virtual Machine (VM) identified in the message cannot be removed from the VM group because the entered VM ID is not associated to the VM group.
Recommended Response Action
Enter a valid and availableVM ID which is associated to the group, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0118

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move Virtual Machine (VM) arg1 because 1) VM does not belong source group. 2) VM is already exist in the destination group.
Arguments
  • arg1 = vmName
Detailed Description
The Virtual Machine (VM) cannot be moved because 1) VM does not belong source group. 2) VM is already exist in the destination group.
Recommended Response Action
Make sure that the Virtual Machine (VM) identified in the message is present in source Virtual Machine Group and not part of destination Virtual Machine Group and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0119

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Virtual machine(s) are successfully added in the Virtual Machine group arg1.
Arguments
  • arg1 = groupName
Detailed Description
The Virtual Machines (VMs) are added to the VM group identified in the message.
Recommended Response Action
Noresponse action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0120

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Virtual machine(s) are successfully removed from the Virtual Machine group arg1.
Arguments
  • arg1 = groupName
Detailed Description
The Virtual Machines (VMs) are removed from the VM group identified in the message.
Recommended Response Action
Noresponse action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0121

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to get rack placeable device details because 1) Device ID is invalid. 2) Device is not rack mountable. 3) Device is already added to rack. 4) Device size details does not exist or is invalid.
Detailed Description
Data about the rack-placeable device cannot be retrieved because 1) Device ID is invalid. 2) Device is not rack mountable. 3) Device is already added to rack. 4) Device size details does not exist or is invalid.
Recommended Response Action
Enter a valid device ID and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0122

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move the device within the rack because the device is of type PDU.
Detailed Description
The device cannot be moved within the rack because the device of type Power Distribution Unit (PDU).
Recommended Response Action
Makesure that device to be moved is not PDU device type and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0123

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to retrieve the device data because of one or more of the following reasons: 1) The device ID is invaid. 2) The device is not rack-mountable. 3) The device is already added to a rack. 4) The device size data does not exist or is invalid.
Detailed Description
The device data cannot be retrieved because of one or more of the following reasons: 1) The device ID is invaid. 2) The device is not rack-mountable. 3) The device is already added to a rack. 4) The device size data does not exist or is invalid.
Recommended Response Action
Make sure that the device ID is valid and have valid size information associated tothem, and then retry the operation. For information about valid rack-mountabledevices, see the OpenManage Enterprise Users Guide available on thesupport site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0124

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device arg1 is successfully moved from rack arg2 to rack arg3.
Arguments
  • arg1 = deviceName
  • arg2 = fromGroup
  • arg3 = toGroup
Detailed Description
The device identified in the message is successfully moved from one rack group to the other rack group.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0125

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power consumed by the device arg1, for policy arg2, has exceeded or equals the power cap threshold value of arg3.
Arguments
  • arg1 = deviceName
  • arg2 = policyName
  • arg3 = thresholdPolicy
Detailed Description
The Power Consumption of the device has exceeded or equals the defined power cap threshold.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0126

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power consumed by the group arg1, for policy arg2, has exceeded or equals the power cap threshold value of arg3.
Arguments
  • arg1 = groupName
  • arg2 = policyName
  • arg3 = thresholdPolicy
Detailed Description
The Power Consumption of the group has exceeded or equals the defined power cap threshold.
Recommended Response Action
No response action is required.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0127

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The location information is successfully updated on the device based on the physical hierarchy data.
Detailed Description
The location information is updated on the device based on the physical hierarchy grouping information in OpenManage Enterprise.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0128

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the device location data in arg1 by using similar data configured in the console because the device cannot be detected.
Arguments
  • arg1 = targetName
Detailed Description
The location information cannot be updated on the device based on the physical hierarchy grouping information in OpenManage Enterprise because the device cannot be detected.
Recommended Response Action
Make sure that the target device is available and retry the operation. For information about detecting the device, see the OpenManage Enterprise Users Guide available on the support site.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0129

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The physical location of device in iDRAC, CMC, or MSM need not be updated or synced with the data configured in the console because both device location data are the same.
Detailed Description
The physical location of device in iDRAC, CMC, or MSM need not be updated or synced with the data configured in the console because both device location data are the same.
Recommended Response Action
Make sure that the devices whose location matches the physical hierarchy are removed from the list, and then retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0130

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The policy arg1 is activated on arg2.
Arguments
  • arg1 = policyName
  • arg2 = deviceName or groupName
Detailed Description
The policy identified in the message is activated on the device or group. This activation impacts the powercap of the device or group.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0131

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power-Throttle or Shutdown EPR is enabled on the group arg1 by the temperature-trigged policy arg2.
Arguments
  • arg1 = groupName
  • arg2 = policyName
Detailed Description
The Power-Throttle or Shutdown EPR is enabled on the group by the temperature-triggered policy identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0132

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The manual EPR is applied on the arg1.
Arguments
  • arg1 = deviceName or groupName
Detailed Description
The manual EPR is applied on the device or group identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0133

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The policy arg1 is deactivated on arg2.
Arguments
  • arg1 = policyName
  • arg2 = deviceName or groupName
Detailed Description
The policy identified in the message is deactivated on the device or group. This activation impacts the powercap of the device or group.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0134

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power-Throttle or Shutdown EPR is disabled on the group arg1 by the temperature-trigged policy arg2.
Arguments
  • arg1 = groupName
  • arg2 = policyName
Detailed Description
The Power-Throttle or Shutdown EPR is disabled on the group by the temperature-triggered policy identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0135

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The manual EPR is revoked on the arg1.
Arguments
  • arg1 = deviceName or groupName
Detailed Description
The manual EPR is revoked on the device or group identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0136

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to implement the resolution arg1 on target arg2. An incorrect resolution value is entered or target device is not reachable.
Arguments
  • arg1 = resolutionType
  • arg2 = targetName
Detailed Description
The resolution value identified in the message cannot be implemented because an incorrect resolution value is entered or target device is not reachable. For information about supported values, see the OpenManage Enterprise Users Guide available on the support site.
Recommended Response Action
Make sure that the resolution value entered is correct and target device is reachable.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0137

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to start the task because a task of similar type is already running.
Detailed Description
The task cannot be started because a task of similar type is already running.
Recommended Response Action
Cancel the current task or wait for the task to complete, and then retry the operation.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0138

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to implement the resolution arg1 on target arg2. The resolution is not applicable for the targeted device.
Arguments
  • arg1 = resolutionType
  • arg2 = targetName
Detailed Description
The resolution type identified in the message cannot be implemented because non applicable resolution type is entered.
Recommended Response Action
Enter a valid resolution value that can applied on the target device, and then retry the operation.
Category
Audit (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0139

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power-Throttle or Shutdown EPR is enabled on the device arg1 by Liquid Cooling System alert.
Arguments
  • arg1 = deviceName
Detailed Description
The Power-Throttle or Shutdown EPR is enabled by Liquid Cooling System alert on the device identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0140

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Power-Throttle or Shutdown EPR which was enabled earlier on the device arg1 by Liquid Cooling System alert is disabled.
Arguments
  • arg1 = deviceName
Detailed Description
The Power-Throttle or Shutdown EPR which was enabled by Liquid Cooling System alert earlier on the device identified in the message is disabled.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0141

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The properties of the group arg1 and the group hierarchy are successfully updated for power management and monitoring.
Arguments
  • arg1 = groupName
Detailed Description
The properties of the group identified in the message are successfully updated for power management and monitoring.
Recommended Response Action
No response action is required.
Category
Configuration (CPWR = Power Configuration)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0142

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to add the device arg1 to the physical group arg2 because the device is already associated or placed in a physical group that is part of another hierarchy.
Arguments
  • arg1 = deviceName
  • arg2 = physicalGroupLocation
Detailed Description
The device cannot be added to the physical group because the device is already associated or placed in a physical group that is part of another hierarchy identified in the message.
Recommended Response Action
Disassociate or remove the device from rack slot and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0143

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to move the device arg1 because the device is associated with the hierarchy arg2 and cannot be moved to another hierarchy.
Arguments
  • arg1 = deviceName
  • arg2 = physicalGroupLocation
Detailed Description
The device cannot be moved because the device is associated with another hierarchy and cannot be moved outside the hierarchy identified in the message.
Recommended Response Action
Make sure that the device is not associated with any physical group and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0144

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the parent hierarchy of the group arg1 because the UPS device is associated with it.
Arguments
  • arg1 = groupName
Detailed Description
The parent hierarchy of a group cannot be updated because the UPS device is associated with a group identified in the message.
Recommended Response Action
Make sure that the device is not associated with any physical group and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0145

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to remove the device arg1 from the physical group arg2 because the device is associated with the physical group arg3.
Arguments
  • arg1 = deviceName
  • arg2 = physicalGroupLocation
  • arg3 = rootPhysicalGroupLocation
Detailed Description
The device cannot be removed from the physical group because the device is associated with another physical group identified in the message.
Recommended Response Action
Make sure that the device is not associated with any physical group and retry the operation.
Category
Configuration (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0163

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to collect the metrics for the device arg1.
Arguments
  • arg1 = deviceName
Detailed Description
The metrics cannot be collected for the device identified in the message.
Recommended Response Action
Ensure the device meets the following requirements: 1) It is reachable. 2) It is discovered with valid authentication credentials. 3) It has the necessary license. 4) It has not exceeded the telemetry metric report definition limit.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0164

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to collect the metrics for the device arg1 and several other devices.
Arguments
  • arg1 = deviceName
Detailed Description
The metrics cannot be collected for the device identified in the message and several other devices.
Recommended Response Action
Ensure the device meets the following requirements: 1) It is reachable. 2) It is discovered with valid authentication credentials. 3) It has the necessary license. 4) It has not exceeded the telemetry metric report definition limit.
Category
System Health (CPWR = Power Configuration)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

CPWR0166

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IRC device arg1 reported a critical failure, which triggered the arg2 of the rack device arg3. The current operation status is arg4.
Arguments
  • arg1 = irc_device_name
  • arg2 = shutdown_type
  • arg3 = rack_device_name
  • arg4 = operation_status
Detailed Description
The IRC device indicated critical failure triggering shutdown of rack device.
Recommended Response Action
Resolve the IRC critical alerts, then power on the affected devices.
Category
System Health (CPWR = Power Configuration)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\