PowerEdge Servers Error and Event Messages Reference Guide

PDF

DIAG—Diagnostics Event Messages

DIAG0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Pass.
Detailed Description
All Tests passed.
Recommended Response Action
OK, life is good.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0111

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 : arg2 exception occurred.
Arguments
  • arg1 = CPU Number
  • arg2 = Exception Type
Detailed Description
No detailed description available.
Recommended Response Action
Issue is on system board. Recommend flash the latest BIOS and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0112

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 - Machine check exception detected.
Arguments
  • arg1 = CPU Number
Detailed Description
No detailed description available.
Recommended Response Action
Issue is on system board. Recommend flash the latest BIOS and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to start application processor(s). :OR: CPU arg1 (ID 0xarg2) did not reach test step arg3.:OR: CPU arg4 (ID 0xarg5) recorded unknown test result 0xarg6.:OR: CPU arg7 (ID 0xarg8) data error at address 0xarg9. Expected arg10.
Arguments
  • arg1 = Decimal
  • arg2 = Hex
  • arg3 = Decimal
  • arg4 = Decimal
  • arg5 = Hex
  • arg6 = Hex
  • arg7 = Decimal
  • arg8 = Hex
  • arg9 = Hex
  • arg10 = Hex
Detailed Description
Depends on <Error Reason>. If it is "Unable to start" it usually indicates a software problem. "Cache integrity" could signal a processor cache hardware problem. The other CPU messages could result from hardware or from overheating, if for instance, the fans are marginal or airflow is blocked.
Recommended Response Action
Check temperatures in System Health tab for abnormally high temperatures and make sure airflow baffles are properly installed in the system, if any. Check fan RPM in System Health tab and verify actual fans are properly installed.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0115

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU Stress Thermal condition. Limit arg1C, Actual arg2C.
Arguments
  • arg1 = Degrees
  • arg2 = Degrees
Detailed Description
No detailed description available.
Recommended Response Action
Check fans. Check for obstructed air vents. Check for excessive amounts of dust.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0121

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory errors detected, but successfully resolved.
Detailed Description
No detailed description available.
Recommended Response Action
MemRx is enabled and repaired all memory errors that were found. DIMM replacement is optional.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0122

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory errors detected. Limit exceeded. Additional errors will not be resolved.
Detailed Description
No detailed description available.
Recommended Response Action
MemRx is enabled and detected too many errors for safe resolution. Recommend DIMM replacement.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0123

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
UEFI: Memory error detected. :OR: LEGACY: Memory - integrity test discrepancy.
Detailed Description
No detailed description available.
Recommended Response Action
MemRX not enabled or not supported. Servers UEFI: Power down system and re-seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Client LEGACY: Power down system and re-seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Check for latest BIOS.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0124

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1, arg2.
Arguments
  • arg1 = Timestamp
  • arg2 = Log message
Detailed Description
Log message is different for the log type supported by the system. An IPMI log may refer to "SEL", other log types also exist.
Recommended Response Action
Depends on <Log message>.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0125

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The event log indicates degraded or disabled ECC functionality. Memory testing cannot continue until the problems are corrected, the log cleared and the system rebooted.
Detailed Description
IPMI System Event Log is full for various reasons or logging has stopped because too many ECC errors have occurred.
Recommended Response Action
Clear the log and reboot and retest.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0126

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The event log(s) must be cleared before testing can continue.
Detailed Description
No detailed description available.
Recommended Response Action
Clear the log, reboot, and retest.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0131

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - The battery is not installed.
Detailed Description
No detailed description available.
Recommended Response Action
Install the battery but check for debris or damaged contacts.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0132

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - The battery is reaching the end of its usable life.
Detailed Description
No detailed description available.
Recommended Response Action
Replace the battery.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0133

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - The battery cannot provide sufficient power.
Detailed Description
No detailed description available.
Recommended Response Action
Check battery contacts, plugs and cables. May need to replace battery.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0134

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - Charge cycles exceeded maximum limit. :OR: Charger - Charge cycles exceeded maximum limit.
Detailed Description
Message "Charger -" changed to "Battery -" in 2/8/2016.
Recommended Response Action
Battery health data indicates the maximum number of charge cycles has been reached. Replace the battery.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0135

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - Not a Dell battery. System will not charge this battery.
Detailed Description
Thisis a new battery error code that was added when the detection of non-Dellbatteries was added to ePSA.
Recommended Response Action
Replace battery with a Dell branded battery.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

DIAG0137

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Charger - Unexpected charge condition detected.
Detailed Description
Thisreplaced the older error code of 2000-0135.
Recommended Response Action
Charger detection changed state when it was not expected to. Re-run the diagnostic with the charger attached as directed by the test.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

DIAG0141

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive - No Hard Drive detected.
Detailed Description
No detailed description available.
Recommended Response Action
Hard drives are not required on all systems so this message is usually a warning. Desktops and Servers: If the system has a hard disk, power down system and check the signal and power connections to it. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0142

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - S/N arg2, arg3 self test unsuccessful arg4.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
  • arg3 = DST Short, DST Long
  • arg4 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
If <Error Reason> is "terminated" then the disk controller terminated the test so a retry of the test is advisable. Otherwise the hard drive should be replaced. {In the factory, this test type may also be DEFT, in addition to DST Short and DST Long. The "terminated" case should not occur in the field, only in development due to software issues}.
Category
Storage (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0143

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - SMART read command unsuccessful.
Arguments
  • arg1 = Drive Location
Detailed Description
Mainly seen with very old hard drives.
Recommended Response Action
No response action is required.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0144

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - self test not supported.
Arguments
  • arg1 = Drive Location
Detailed Description
Mainly seen with very old hard drives.
Recommended Response Action
No response action is required.
Category
Storage (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0145

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - S/N arg2, self test did not complete.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
Detailed Description
No detailed description available.
Recommended Response Action
Desktops and Servers: Power down the system and check the signal and power connections to the hard drive. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0146

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - S/N arg2, self test log contains previous error(s).
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
Detailed Description
Prior failure checking removed, is now obsolete.
Recommended Response Action
No response action is required.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0147

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Optical Drive arg1 - Self test: arg2.
Arguments
  • arg1 = Nth Drive
  • arg2 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
This typically is a user error since these drives can be disconnected from the system. If disconnected, reconnect the optical drive to system board. Check BIOS setup to make sure the SATA port the drive is connected and has not been disabled. Rerun the diagnostic. If errors persist the optical drive is defective.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0148

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard/Optical Drive arg1 - incorrect status: arg2 arg3.
Arguments
  • arg1 = Nth Drive
  • arg2 = Hex
  • arg3 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0149

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Optical Drive - no drive detected.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0150

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive - No Hard Drive detected, or disk controller not supported.
Detailed Description
No detailed description available.
Recommended Response Action
Hard drives on desktops should be found if connected to the chipset disk controller but PERC/SCU/SAS Adapters are not supported by legacy ePSA so if the hard drive is connected to these controllers this message is just a warning. If the system has a hard disk connected to the System Board chipset disk controller, power down the system and check the signal and power connections to it. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0151

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive arg1 - S/N arg2, incorrect status = arg3\narg4.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
  • arg3 = 80000000000000??
  • arg4 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
SMART Predictive Failure indicates the hard drive has failed SMART and maybe nearing the end of its life. Other types of <Error Reason> in this category may indicate an intermittent or firmware problem, rerun the test again. Desktops, servers: Check the hard disk drive cables and connections. All systems: If error persists, make sure that hard disk drive firmware and BIOS are current. The <80000000000000??> value is an EFI error code returned by the driver.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0152

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Optical Drive arg1 - Incorrect status = arg2 arg3.
Arguments
  • arg1 = Nth Drive
  • arg2 = Hex
  • arg3 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
Check the drive cables and connections. If error persists, make sure that drive firmware and BIOS are current. The <80000000000000??> value is an EFI error code returned by the driver.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0154

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Tape Drive arg1 - S/N arg2, incorrect status = arg3\narg4.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
  • arg3 = 80000000000000??
  • arg4 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
Check installation of the tape drive, cables and connections. If the error persists, ensure that drive firmware is current.
Category
Storage (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0155

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive - Not installed.
Detailed Description
No detailed description available.
Recommended Response Action
Power down system and check the signal and power connections to the hard drive. Rerun the diagnostic. If no error occurs then it was a cable or connector issue. This error is issued for notebooks which must have a hard disk so it is an error if not found.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0161

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The NVMe drive is not detected on the PCI tag arg1, NameSpace ID arg2.
Arguments
  • arg1 = name
  • arg2 = name
Detailed Description
The NVMe drive is not detected on the PCI tag identified in the message. An NVMe drive may be installed but is not working to expose the NVMe pass-through protocol interface.
Recommended Response Action
Replace the NVMe drive.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0212

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - CMOS, Location = arg1h, Expected = arg2h, Found = arg3h.
Arguments
  • arg1 = Hex
  • arg2 = Hex
  • arg3 = Hex
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the system is running with the latest BIOS and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0213

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - CMOS battery failure detected.
Detailed Description
No detailed description available.
Recommended Response Action
Replace the CMOS battery and retry the diagnostic. If the error persists, make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0221

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - Interval timer not functional.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0232

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
RTC - did not generate periodic ticks.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0233

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - RTC seconds count is not updating.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0234

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - HPET arg1, incorrect time period. Expected = arg2, Found = arg3.
Arguments
  • arg1 = 1
  • arg2 = Decimal
  • arg3 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0235

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PM timer 1 had wrong time period. Expected arg1, Actual arg2.
Arguments
  • arg1 = Decimal
  • arg2 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0241

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
BIOS - A20 gate not enabled.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0242

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - Interrupt controller, IRQ = arg1: arg2 not detected.
Arguments
  • arg1 = Decimal
  • arg2 = IRQ Description
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0243

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
USB controller error.
Detailed Description
No detailed description available.
Recommended Response Action
Ensure that USB ports are intact, contain no failed device and that BIOS is current. After corrective action, rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0244

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
USB device failed with return code 0xarg1.
Arguments
  • arg1 = Hex
Detailed Description
No detailed description available.
Recommended Response Action
Ensure that the USB device is correctly inserted or try another USB port or device. After corrective action, rerun the diagnostics. If the problem persists, ensure that BIOS is current.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0245

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Timeout waiting for the device to respond.
Detailed Description
No detailed description available.
Recommended Response Action
Ensure that the USB device is correctly inserted or try another USB port and/or to see if it is just a particular device or port. After corrective action, rerun the diagnostics. If the problem persists, ensure that BIOS is current.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0251

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Event log - The log contains failing records.
Detailed Description
No detailed description available.
Recommended Response Action
This is normally a warning message indicating that the Event Log has not been checked lately. The Event Log provides various BIOS and Diagnostic events.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0261

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System board - Data errors.
Detailed Description
No detailed description available.
Recommended Response Action
This is an error message for multiple DIMM failures. Replace the memory one module at a time and re-run the diagnostics. If issue persists, replace the motherboard.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0313

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Touchpad - Pointing stick/touchpad not detected.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the device firmware and BIOS are current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0314

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Thermal: The (arg1) reading (arg2C) exceeds the thermal limit.
Arguments
  • arg1 = Sensor Name
  • arg2 = Degrees
Detailed Description
No detailed description available.
Recommended Response Action
Check the event log for thermal events, including defective fans and defective sensors. Inspect the system for clogged or obstructed air vents. Make sure that the BIOS is current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0315

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Sensor: The (arg1) reading arg2C) is lower than expected.
Arguments
  • arg1 = Sensor Name
  • arg2 = Degrees
Detailed Description
No detailed description available.
Recommended Response Action
Check the event log for thermal events, including defective fans and defective sensors. Inspect the system for clogged or obstructed air vents. Make sure that the BIOS is current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0321

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD EDID - Unable to access EDID EEPROM.
Detailed Description
No detailed description available.
Recommended Response Action
This could relate to the LCD connector and cables. Otherwise, flash the latest BIOS and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0322

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - Unable to modify brightness.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that BIOS is current and rerun diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0323

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect inverter lamp status.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0324

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - User reported LCD BIST colors were not displayed.
Detailed Description
No detailed description available.
Recommended Response Action
Possible user error, make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0325

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - User provided no input for LCD BIST.
Detailed Description
No detailed description available.
Recommended Response Action
Possible user error, make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0326

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - Unable to turn lamp on or off.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0327

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - Unable to use BIOS interface.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0328

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD panel - Unable to detect variance in ambient light sensor.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0331

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video controller - No video controller detected.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0332

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video memory - Video memory integrity test discrepancy.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that the BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0333

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video - User provided no input for graphics test.
Detailed Description
No detailed description available.
Recommended Response Action
No response to a diagnostic prompt and a timeout occurred. Retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0334

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video - User reported the patterns were not displayed.
Detailed Description
No detailed description available.
Recommended Response Action
Possible user error. Otherwise, make sure that BIOS is current and retry diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0411

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - arg1 not detected.
Arguments
  • arg1 = Hardware Name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0412

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - arg1 not detected.
Arguments
  • arg1 = AUX LCD Name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0413

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD Cable - LCD cable is not installed.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0414

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - arg1 not detected.
Arguments
  • arg1 = Inverter Name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0415

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - Check the following cable, jumper, connection, or sensor: arg1.
Arguments
  • arg1 = Name
Detailed Description
No detailed description available.
Recommended Response Action
Connect the described cable, jumper, sensor, or connection and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0511

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - The (arg1) fan failed to respond correctly.
Arguments
  • arg1 = Name
Detailed Description
No detailed description available.
Recommended Response Action
The fan may be faulty, check for obstructions to the fan and vents. Make sure that BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0512

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - The (arg1) fan is running faster than expected.
Arguments
  • arg1 = Name
Detailed Description
No detailed description available.
Recommended Response Action
Retry the diagnostics; if the problem persists, the fan is faulty. Make sure that the BIOS is current and retry the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0620

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Network arg1 - arg2.
Arguments
  • arg1 = Number
  • arg2 = Failure Message
Detailed Description
UEFI Driver provides a DIAGNOSTIC protocol and this protocol supplies a test that failed. Failure Message may be "Packet loopback test failed" or "Register test failed" or something else. Provided by driver not ePSA.
Recommended Response Action
The Network (Ethernet) device may be faulty. Check for bent pins in the Ethernet connector. Make sure that Network device firmware is current. Retry test, if still fails, replace the NIC/NDC/LOM Network device. This may be on the motherboard, or an adapter, or a daughter card, depending on the system.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0621

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Network arg1 - Driver version arg2 outdated. Version arg3 or newer required for "arg4".
Arguments
  • arg1 = Number
  • arg2 = Hex
  • arg3 = Hex
  • arg4 = EFI Driver Name
Detailed Description
Test only warns because UEFI Network Driver is old and has known false failures.
Recommended Response Action
Update Network firmware.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0711

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Thermal - Thermal trip detected.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
System detected repeated thermal trips due to excessive heat. Check for obstructions to the fan and vents. Make sure BIOS is current and rerun diagnostics. If error persists replace thermal heat sink, CPU and motherboard.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0712

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - The fan failed to respond correctly.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected repeated issues when setting the fan speed. The fan may be faulty, check for obstructions to the fan and vents. Make sure the BIOS is current and rerun diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0713

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Sensor - Error accessing thermal sensor.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS error when reading the systems thermal sensor. Make sure the BIOS is current and rerun diagnostics. If error persists, replace the motherboard.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0714

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Heat Sink - Heat sink clip not installed.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected that the heat sink clip was not installed. Connect the heat sink clip properly.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0715

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory - Memory error detect.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected an issue configuring the DIMM. Check for latest BIOS. Power down system and reseat DIMMs. Retry test; if no error occurs it was a DIMM connection issue. If error persists, replace the DIMM.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0716

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - Check the following cable, arg1.
Arguments
  • arg1 = Cable Name
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected a cable that was not installed. Connect the cable that is described in the string portion of the message.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0721

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - Battery issue detected.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected a battery that is not functioning properly. Remove and replace the battery. Rerun the diagnostics on the new battery once it is charged.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0722

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory - Previous uncorrectable memory error.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected an un-correctable memory issue on a prior boot. Update to the latest BIOS. Power down system and reseat DIMMs. Retry test; if no error occurs it was a DIMM connection issue. If error persists, replace the DIMM.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG0723

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hard Drive - Drive error detected.
Detailed Description
BIOS error reported through ePSA.
Recommended Response Action
BIOS detected a hard drive issue. Make sure hard drive connection is good, and the drive firmware and system BIOS are current. If error persists, replace the hard drive.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
No BIOS support for software interrupt arg1h, function(ah) arg2h.
Arguments
  • arg1 = Hex
  • arg2 = Hex
Detailed Description
No detailed description available.
Recommended Response Action
Should not occur.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
No BIOS support for SMI interface function(ah) arg1h.;Sensor arg2 exceeded thermal zone arg3. Peak zone was arg4.
Arguments
  • arg1 = Hex Function
  • arg2 = Name
  • arg3 = Decimal
  • arg4 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
System thermal sensor is indicating a high value. Clear any blockage to internal fans and heat sinks. Make sure that BIOS is current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - Unable to set Manufacturing Mode.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that BIOS is current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - Unable to determine fan speeds.
Detailed Description
No detailed description available.
Recommended Response Action
Make sure that BIOS is current and rerun the diagnostics.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD BIST not supported. :OR: Fan - Fan speed failure. Expected at least arg1, observed arg2.
Arguments
  • arg1 = RPM
  • arg2 = RPM
Detailed Description
No detailed description available.
Recommended Response Action
If LCD BIST error: The LCD BIST may not exist on all systems. Make sure that the BIOS is current and rerun the diagnostics. If Fan speed error: Insure fans are not dirty or obstructed and check for a loose connection.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan - Unable to set fans to arg1 speed. :OR: No chipset event timer.
Arguments
  • arg1 = High, Low, Original
Detailed Description
No detailed description available.
Recommended Response Action
Fan is not operating at the expected speed. Make sure that BIOS is current and rerun the diagnostics. If problem persists, replace the fan.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Log contains Fan events:OR:Timer expected arg1 observed arg2.
Arguments
  • arg1 = Decimal
  • arg2 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
For "Log contains Fan events", the events are placed in the log by other sources and ePSA is merely reporting them.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Out of memory! fMalloc() Failed! :OR: Unable to allocate memory for object data. :OR: Unable to arg1 testable memory. :OR: Unable to start application processor(s) :OR: Unable to stop all APs. The system may be unstable and should be rebooted.
Arguments
  • arg1 = Name
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cannot find memory to free! fFree() Failed with pointer arg1.
Arguments
  • arg1 = Hex
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
High-Precision event timer not found.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Invalid status return from the device.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Invalid parameter passed to the device. :OR: Unknown test (arg1) selected.
Arguments
  • arg1 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
LCD arg1 does not support test commands.
Arguments
  • arg1 = Name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
ADDF module (arg1) device (arg2) failed with error code arg3, number arg4. No EPSA beep code mapped.
Arguments
  • arg1 = Name
  • arg2 = Name
  • arg3 = Hex
  • arg4 = hex
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to stop all APs. The system may be unstable and should be rebooted.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - unable to retrieve battery health.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Battery - BIOS has no support for battery health.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fatal: The module reported multiple test results.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to log to NVRAM.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Low memory. arg1k bytes free.
Arguments
  • arg1 = Decimal
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
SMBIOS DIMM configuration did not match.
Detailed Description
No detailed description available.
Recommended Response Action
Software error, should not normally occur in field.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8138

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Charger - The AC power adapter wattage and type cannot be determined. The battery may not charge.
Detailed Description
Added 01/18/2016 to ePSA code.
Recommended Response Action
A bad charger or a non-Dell charger is being used on the system.Replace the charger.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

DIAG8154

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Tape Drive arg1 - S/N arg2, ULTRIUM arg3 media found but drive requires ULTRIUM arg4 for arg5.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
  • arg3 = Generation
  • arg4 = Generation
  • arg5 = writes
Detailed Description
Each generation of ULTRIUM Tape drives usually supports the previous generation but not newer generation tape media.
Recommended Response Action
Install the correct tape media.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8155

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Tape Drive arg1 - S/N arg2, data read does not match data written.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
Detailed Description
Data written on the tape read back differently, not as expected.
Recommended Response Action
Use a different tape media.
Category
Storage (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8156

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Tape Drive arg1 - S/N arg2, no media, cannot test drive.
Arguments
  • arg1 = Drive Location
  • arg2 = Serial Number
Detailed Description
Testing requires scratch tape media.
Recommended Response Action
Install tape media or skip test.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8157

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 Drive arg2 - S/N arg3, drive is not a supported drive.
Arguments
  • arg1 = Tape|Disk
  • arg2 = Drive Location
  • arg3 = Serial Number
Detailed Description
If <Tape> then only Dell tape drives are tested and supported. If <Disk> then disk drive may not be a Dell drive.
Recommended Response Action
Customer appears to have added a non-Dell Tape drive to his system.
Category
Storage (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8158

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 Drive arg2 - S/N arg3, incorrect status = arg4\narg5.
Arguments
  • arg1 = Backplane|Expander|RD1000
  • arg2 = Drive Location
  • arg3 = Serial Number
  • arg4 = 80000000000000??
  • arg5 = Error Reason
Detailed Description
A device failed a command and testing cannot complete.
Recommended Response Action
Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8160

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PERC Battery arg1 - incorrect status = arg2\narg3.
Arguments
  • arg1 = PERC Controller Location
  • arg2 = 80000000000000??
  • arg3 = Error Reason
Detailed Description
No detailed description available.
Recommended Response Action
If <Error Reason> is (Battery missing or disconnected) then check the battery cable to the PERC controller. If <Error Reason> is (Replace battery pack) then replace battery pack. If <Error Reason> is (Remaining capacity low) then battery pack may need to be replaced soon.
Category
Storage (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8166

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
OS - Suspect corrupt MBR, verify MBR with Anti-Virus Application.
Detailed Description
No detailed description available.
Recommended Response Action
Run virus scan.
Category
Storage (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8170

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PCIe - Training error PCI Tag-arg1 VendorID-arg2 DeviceID-arg3SVid-arg4SDid-arg5 Bus arg6: Link Degraded, maxLinkWidth = xarg7, negotiatedLinkWidth = xarg8, Slot arg9.
Arguments
  • arg1 = tag
  • arg2 = hex
  • arg3 = hex
  • arg4 = hex
  • arg5 = hex
  • arg6 = decimal
  • arg7 = decimal
  • arg8 = decimal
  • arg9 = slot
Detailed Description
A PCI device is functioning at a lower performance that it should be. If the device is in a physical PCI slot then ", Slot <decimal>" will be appended to the message.
Recommended Response Action
Reseat the PCI-Express adapter described and retest.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8171

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PCIe - PCI device in physical Slot arg1, PCI Tag arg2, is present but not responding.
Arguments
  • arg1 = decimal
  • arg2 = hex
Detailed Description
A PCI adapter was detected as present but it does not respond to PCI Configuration Space access, so is very sick or not inserted snugly in the PCI physical slot connector.
Recommended Response Action
Reseat or replace PCI adapter in the PCI slot indicated.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8172

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PCIe - Speed slow PCI Tag-arg1 VendorID-arg2 DeviceID-arg3SVid-arg4SDid-arg5 Bus arg6: Link Trained xarg7, Speed Max arg8 GT/s, Neg arg9 GT/s, Slow Slot arg10.
Arguments
  • arg1 = tag
  • arg2 = hex
  • arg3 = hex
  • arg4 = hex
  • arg5 = hex
  • arg6 = decimal
  • arg7 = decimal
  • arg8 = speed
  • arg9 = speed
  • arg10 = slot
Detailed Description
A PCI device is functioning at a lower performance that it should be. If the device is in a physical PCI slot then ", Slot <decimal>" will be appended to the message.
Recommended Response Action
Reseat the PCI-Express adapter described and retest.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8173

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PCIe - PCI device at PCI tag arg1 is intermittently discoverable.
Arguments
  • arg1 = tag
Detailed Description
A PCI Device is not always functioning properly. Sometimes is not discoverable when scanning for PCI devices.
Recommended Response Action
Reseat the PCI-Express Adapter described and retest.
Category
System Health (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

DIAG8335

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video - User indicated that one or more full color screens showed pixel errors.
Detailed Description
ARM-based tablets only.
Recommended Response Action
Verify visually that there are pixels of the wrong color or missing. Replace LCD panel. If all pixels of one color are missing, replace video controller or motherboard.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8336

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video - User indicated that the Grey Scale screen is not properly displayed.
Detailed Description
ARM-based tablets only.
Recommended Response Action
Verify visually that the grey scales are not showing properly. Replace LCD panel.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8337

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Video - User indicated that the Cross Hatch screen is not properly displayed.
Detailed Description
ARM-based tablets only.
Recommended Response Action
Verify visually that the cross hatch pattern has mismatches. Adjust the convergence settings on the LCD panel. Repeat the test. If error continues, replace the LCD panel or video controller.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8338

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 - DriverBinding-Supported() function, Version arg2, changed PCI Command Reg of device arg3.
Arguments
  • arg1 = Module
  • arg2 = Hex
  • arg3 = Tag
Detailed Description
No detailed description available.
Recommended Response Action
The initial string indicates the uEFI driver with an issue. Update the BIOS to the latest version.
Category
System Health (DIAG = Diagnostics)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8415

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cables - BIOS reports no testable cable/jumper/connector/sensor.
Detailed Description
No detailed description available.
Recommended Response Action
Update the BIOS to the latest version.
Category
Configuration (DIAG = Diagnostics)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DIAG8611

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
User reported not hearing speaker tone.
Detailed Description
No detailed description available.
Recommended Response Action
If the beep was not heard, verify the internal speakers are connected properly. On some systems, internal speakers are a purchased option. For a given system, if the speaker is optional, it might not exist on that system. If audio is not heard, make sure to unplug anything plugged into an external headphone jack and rerun the test. External HP jacks can mute the internal speakers at the hardware level.
Category
System Health (DIAG = Diagnostics)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\