PowerEdge Servers Error and Event Messages Reference Guide
DPU—Data Processing Unit Event Messages
DPU9026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 operating system is successfully working.
- Arguments
- arg1 = DPU Friendly FQDD
- Detailed Description
- The DPU operating system and its services are restarted, and successfully working.
- Recommended Response Action
- No response action is required.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operating system of arg1 is not ready for normal function because either the boot synchronization period has timed out or the boot synchronization timeout value is too less.
- Arguments
- arg1 = DPU Friendly FQDD
- Detailed Description
- The operating system of the DPU identified in the message is not ready for normal function because either the boot synchronization period has timed out or the boot synchronization timeout value is too less.
- Recommended Response Action
- Increase the DPUOSReadyTimeout value based on your DPU configuration. If the issue persists, reinstall the DPU operating system and power on the server.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- All the boot synchronization-enabled DPU operating systems are ready.
- Detailed Description
- All the boot synchronization-enabled DPU operating systems are ready.
- Recommended Response Action
- No response action required.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Informational
- Trap/EventID
- 3283
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Graceful Shut Down operation of the host OS is initiated. The shutdown operation of the OSs of the respective Data Processing Units (DPUs) is initiated.
- Detailed Description
- A Graceful Shut Down operation of the host OS is initiated. The shutdown operation of the OSs of the respective Data Processing Units (DPUs) is initiated.
- Recommended Response Action
- No response action is required.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Informational
- Trap/EventID
- 3283
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The shutdown operation of the OS of the respective DUPs cannot be completed.
- Detailed Description
- Unable to shut down the OS of the respective Data Processing Units (DPUs) because the DPU shutdown timeout value is less.
- Recommended Response Action
- 1) Run the following RACADM command at the CLI to get the DPU shutdown timeout value: racadm get system.dpuGlobalConfiguration.DPUOSShutdownTimeOut.2) Run the following RACADM command at the CLI to increase the DPU shutdown timeout value: racadm set system.dpuGlobalConfiguration.DPUOSShutdownTimeOut <enter new value>.3) Retry the Graceful Shutdown operation of the host device. If the issue persists, reinstall the DPU operating system.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Warning
- Trap/EventID
- 3282
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operating systems of all the Data Processing Units (DPUs) are gracefully shut down.
- Detailed Description
- The operating systems of all the Data Processing Units (DPUs) are gracefully shut down.
- Recommended Response Action
- No response action is required.
- Category
- System Health (DPU = Data Processing Unit)
- Severity
- Informational
- Trap/EventID
- 3283
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 operation has completed successfully on arg2.
- Arguments
- arg1 = Operation_Name
- arg2 = FQDD
- Detailed Description
- The operation identified in the message has completed successfully on the device identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (DPU = Data Processing Unit)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
DPU9033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the arg1 operation on arg2 because the device has stopped responding.
- Arguments
- arg1 = Operation_Name
- arg2 = FQDD
- Detailed Description
- The operation identified in the message cannot be performed because the device has stopped responding.
- Recommended Response Action
- Do one or more of the following: 1) Retry the operation. 2) Perform the Cold Reboot operation on the host device. 3) Restart iDRAC. 4) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Configuration (DPU = Data Processing Unit)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable