PowerEdge Servers Error and Event Messages Reference Guide

PDF

DPU—Data Processing Unit Event Messages

DPU9026

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 operating system is successfully working.
Arguments
  • arg1 = DPU Friendly FQDD
Detailed Description
The DPU operating system and its services are restarted, and successfully working.
Recommended Response Action
No response action is required.
Category
System Health (DPU = Data Processing Unit)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9027

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The operating system of arg1 is not ready for normal function because either the boot synchronization period has timed out or the boot synchronization timeout value is too less.
Arguments
  • arg1 = DPU Friendly FQDD
Detailed Description
The operating system of the DPU identified in the message is not ready for normal function because either the boot synchronization period has timed out or the boot synchronization timeout value is too less.
Recommended Response Action
Increase the DPUOSReadyTimeout value based on your DPU configuration. If the issue persists, reinstall the DPU operating system and power on the server.
Category
System Health (DPU = Data Processing Unit)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
All the boot synchronization-enabled DPU operating systems are ready.
Detailed Description
All the boot synchronization-enabled DPU operating systems are ready.
Recommended Response Action
No response action required.
Category
System Health (DPU = Data Processing Unit)
Severity
Informational
Trap/EventID
3283
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Graceful Shut Down operation of the host OS is initiated. The shutdown operation of the OSs of the respective Data Processing Units (DPUs) is initiated.
Detailed Description
A Graceful Shut Down operation of the host OS is initiated. The shutdown operation of the OSs of the respective Data Processing Units (DPUs) is initiated.
Recommended Response Action
No response action is required.
Category
System Health (DPU = Data Processing Unit)
Severity
Informational
Trap/EventID
3283
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The shutdown operation of the OS of the respective DUPs cannot be completed.
Detailed Description
Unable to shut down the OS of the respective Data Processing Units (DPUs) because the DPU shutdown timeout value is less.
Recommended Response Action
1) Run the following RACADM command at the CLI to get the DPU shutdown timeout value: racadm get system.dpuGlobalConfiguration.DPUOSShutdownTimeOut.2) Run the following RACADM command at the CLI to increase the DPU shutdown timeout value: racadm set system.dpuGlobalConfiguration.DPUOSShutdownTimeOut <enter new value>.3) Retry the Graceful Shutdown operation of the host device. If the issue persists, reinstall the DPU operating system.
Category
System Health (DPU = Data Processing Unit)
Severity
Warning
Trap/EventID
3282
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The operating systems of all the Data Processing Units (DPUs) are gracefully shut down.
Detailed Description
The operating systems of all the Data Processing Units (DPUs) are gracefully shut down.
Recommended Response Action
No response action is required.
Category
System Health (DPU = Data Processing Unit)
Severity
Informational
Trap/EventID
3283
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 operation has completed successfully on arg2.
Arguments
  • arg1 = Operation_Name
  • arg2 = FQDD
Detailed Description
The operation identified in the message has completed successfully on the device identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (DPU = Data Processing Unit)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

DPU9033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform the arg1 operation on arg2 because the device has stopped responding.
Arguments
  • arg1 = Operation_Name
  • arg2 = FQDD
Detailed Description
The operation identified in the message cannot be performed because the device has stopped responding.
Recommended Response Action
Do one or more of the following: 1) Retry the operation. 2) Perform the Cold Reboot operation on the host device. 3) Restart iDRAC. 4) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Configuration (DPU = Data Processing Unit)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\