PowerEdge Servers Error and Event Messages Reference Guide
FAN—Fan Event Event Messages
FAN0000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is less than the lower warning threshold.
- Arguments
- arg1 = number
- Detailed Description
- The fan is not performing optimally. The fan may be installed improperly or may be failing. Fan speeds may have increased to protect the system.
- Recommended Response Action
- Remove and re-install the fan at the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- LCD Message
- Fan <number> RPM is outside of range. Check fan.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is less than the lower critical threshold.
- Arguments
- arg1 = number
- Detailed Description
- The fan is not performing optimally. The fan may be installed improperly or may be failing. Fan speedsmay have increased to protect the system.
- Recommended Response Action
- To resolve any temporary issues in communicating with the fans, restart iDRAC. If the issue persists, do the following: 1) Open the chassis cover and check for any cable interference in the fan blades. 2) Remove the fan (as identified in the iDRAC log) from the server and then reinstall in the same slot. 3) Make sure the fan is removed from its connector on the motherboard. 4) Swap the fan with another fan from a different location in the same server. 5) If the issue persists, replace the fan with a new fan. 6) After installing the new fan in the slot, if the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- LCD Message
- Fan <number> RPM is outside of range. Check fan.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is greater than the upper warning threshold.
- Arguments
- arg1 = number
- Detailed Description
- The fan is not performing optimally. The fan may be installed improperly or may be failing.
- Recommended Response Action
- Remove and re-install the fan at the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is greater than the upper critical threshold.
- Arguments
- arg1 = number
- Detailed Description
- The fan is not performing optimally. The fan may be installed improperly or may be failing.
- Recommended Response Action
- Remove and re-install the fan. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- LCD Message
- Fan <number> RPM is outside of range. Check fan.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is outside of range.
- Arguments
- arg1 = number
- Detailed Description
- The fan is not performing optimally. The fan may be installed improperly or may be failing.
- Recommended Response Action
- Remove and re-install the fan. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- LCD Message
- Fan <number> RPM is outside of range. Check fan.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 RPM is within range.
- Arguments
- arg1 = number
- Detailed Description
- Fan speeds may return to normal.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is removed.
- Arguments
- arg1 = number
- Detailed Description
- The fan may be required for optimal performance.
- Recommended Response Action
- If unintentional, install a fan.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 was inserted.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*
FAN0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is present.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is absent.
- Arguments
- arg1 = number
- Detailed Description
- The fan may be required for optimal performance.
- Recommended Response Action
- If unintentional, install a fan.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- LCD Message
- Fan <number> is absent. Check Fan.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is disabled.
- Arguments
- arg1 = number
- Detailed Description
- The fan may be required for optimal performance.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is enabled.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is less than the lower warning threshold.
- Arguments
- arg1 = name
- Detailed Description
- The device is not performing optimally. The device may be installed improperly.
- Recommended Response Action
- Remove and re-install the device at the next scheduled service. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is less than the lower critical threshold.
- Arguments
- arg1 = name
- Detailed Description
- The cooling device is not performing optimally. The cooling device may be installed improperly.
- Recommended Response Action
- Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is greater than the upper warning threshold.
- Arguments
- arg1 = name
- Detailed Description
- The cooling device is not performing optimally. The cooling device may be installed improperly.
- Recommended Response Action
- Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is greater than the upper critical threshold.
- Arguments
- arg1 = name
- Detailed Description
- The cooling device is not performing optimally. The cooling device may be installed improperly.
- Recommended Response Action
- Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is outside of normal operating range.
- Arguments
- arg1 = name
- Detailed Description
- The cooling device is not performing optimally. The cooling device may be installed improperly.
- Recommended Response Action
- Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 RPM is within normal operating range.
- Arguments
- arg1 = name
- Detailed Description
- The RPM of the fan identified in the message is functioning correctly.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
FAN0018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Enhanced Cooling Mode is not supported for fan arg1.
- Arguments
- arg1 = number
- Detailed Description
- Enhanced Cooling Mode is not supported by the type of fan identified in the message.
- Recommended Response Action
- Replace the fan identified in the message with another fan which supports Enhanced Cooling Mode.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An incompatibility between operating mode and fan type was corrected for fan arg1.
- Arguments
- arg1 = number
- Detailed Description
- An incompatibility between operating mode and fan type was corrected for the fan identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 is non-functional.
- Arguments
- arg1 = fan name
- Detailed Description
- The fan identified in the message has failed or it is not installed correctly.
- Recommended Response Action
- Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- OMSA Event ID
- 5300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 is offline.
- Arguments
- arg1 = fan name
- Detailed Description
- The fan identified in the message is removed. However, the fan may be required for optimal system performance.
- Recommended Response Action
- Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- OMSA Event ID
- 5303
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 sensor has failed, and the last recorded value by the sensor was arg2 RPM.
- Arguments
- arg1 = sensor name
- arg2 = fan speed
- Detailed Description
- The sensor identified in the message has failed. The sensor may be required for optimal system performance.
- Recommended Response Action
- Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- OMSA Event ID
- 5100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0023
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to read the arg1 sensor value.
- Arguments
- arg1 = sensor name
- Detailed Description
- The fan sensor identified in the message has failed or the fan has failed.
- Recommended Response Action
- Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- OMSA Event ID
- 5101
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 sensor returned to a normal state with a value of arg2 RPM.
- Arguments
- arg1 = sensor name
- arg2 = fan speed
- Detailed Description
- The sensor identified in the message has returned to a normal state.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- OMSA Event ID
- 5102
- OMSA Trap ID
- 5102
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
- Arguments
- arg1 = sensor name
- arg2 = fan speed
- Detailed Description
- The fan identified in the message is not functioning correctly. The fan may be installed incorrectly or may be failing.
- Recommended Response Action
- Remove and re-install the fan, or replace the fan. If the issue persists, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- OMSA Event ID
- 5103
- OMSA Trap ID
- 5103
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 sensor detected an error with a value of arg2 RPM.
- Arguments
- arg1 = sensor name
- arg2 = fan speed
- Detailed Description
- The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds.
- Recommended Response Action
- Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- OMSA Event ID
- 5104
- OMSA Trap ID
- 5104
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 sensor has failed with a value of arg2 RPM.
- Arguments
- arg1 = sensor name
- arg2 = fan speed
- Detailed Description
- The sensor identified in the message has failed. The sensor may be required for optimal system performance.
- Recommended Response Action
- Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- OMSA Event ID
- 5105
- OMSA Trap ID
- 5105
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is inserted.
- Arguments
- arg1 = number
- Detailed Description
- The fan identified in the message is inserted.Fan speeds may return to normal.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 is either removed, incorrectly installed, or not present.
- Arguments
- arg1 = number
- Detailed Description
- The fan identified in the message is either removed, incorrectly installed, or not present. Fan speeds may increase to protect the system.
- Recommended Response Action
- Install the fan at the next scheduled service.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- LCD Message
- Fan <number> is either removed, incorrectly installed, or not present.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 configuration mismatch.
- Arguments
- arg1 = number
- Detailed Description
- The configuration of fan identified in the message is not matching with the other fans in the server.
- Recommended Response Action
- Replace the fan with one that has similar configuration during the next scheduled service. For more information about recommended fan configurations, see the iDRAC Users Guide available on the support site.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- LCD Message
- Fan <number> configuration mismatch.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fan arg1 configuration mismatch resolved.
- Arguments
- arg1 = number
- Detailed Description
- The configuration mismatch of fan identified in the message is successfully resolved. For more information about recommended fan configurations, see the iDRAC Users Guide available on the support site.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The communication with arg1 fan arg2 is lost.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The communication with the fan identified in the message is lost.
- Recommended Response Action
- If absent, insert a fan. If the fan is present, remove and reseat into the enclosure. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The communication with arg1 fan arg2 is restored.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The communication with the fan identified in the message is restored.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The speed (RPM) of the arg1 fan arg2 is less than the lower warning threshold.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The speed (RPM) of the fan identified in the message is less than the lower warning threshold value.
- Recommended Response Action
- Remove and reinstall the device during the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Warning
- Trap/EventID
- 2154
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The speed (RPM) of the arg1 fan arg2 is less than the lower critical threshold.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The speed (RPM) of the fan identified in the message is less than the lower critical threshold value.
- Recommended Response Action
- Remove and reinstall the device during the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The speed (RPM) of the arg1 fan arg2 is within the normal operating range.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The speed (RPM) of the fan identified in the message is within the normal operating range.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An issue in the chassis infrastructure hardware or arg1 fan arg2 has affected the chassis thermal control feature.
- Arguments
- arg1 = location
- arg2 = number
- Detailed Description
- An issue in the chassis infrastructure hardware or fan module identified in the message has affected the chassis thermal control feature. However, the chassis thermal control feature is temporarily recovered.
- Recommended Response Action
- If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0100
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The firmware version of the arg1 fan arg2 is successfully updated.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The firmware version of the fan identified in the message is successfully updated.
- Recommended Response Action
- No response action is required.
- Category
- Updates (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware version of the arg1 fan arg2 because of error code = arg3.
- Arguments
- arg1 = location
- arg2 = index
- arg3 = error
- Detailed Description
- The firmware version of the fan identified in the message cannot be updated because of internal issues.
- Recommended Response Action
- Manually remove and reinstall the fan during the next scheduled service window. If the issue, persists, contact your service provider.
- Category
- Updates (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
FAN0200
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 fan arg2 configuration mismatch.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The configuration of the fan identified in the message is not matching with the other fans in the chassis. Some devices may experience varied performance and possible thermal errors depending on the configuration and workload.
- Recommended Response Action
- Replace the fan with one that matches the configuration and type of fan inside MX7000 at the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0201
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 fan arg2 configuration mismatch resolved.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The configuration mismatch of fan identified in the message is successfully resolved. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0202
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 fan arg2 requires attention for optimal performance.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- A device in the chassis requires a fan type that does not match the configuration of the fan identified in the message. Some devices may experience varied performance and possible thermal errors depending on the configuration, workload, and environment.
- Recommended Response Action
- Replace the fan with a Gold Grade (Hardware Version 2) fan during the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
- Category
- System Health (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 2153
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN0203
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The fan type configuration is corrected for arg1 fan arg2.
- Arguments
- arg1 = location
- arg2 = index
- Detailed Description
- The configuration of fan type identified in the message is successfully resolved. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
- Recommended Response Action
- No response action is required.
- Category
- System Health (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 2155
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN1000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 was removed.
- Arguments
- arg1 = Fan Sensor Name
- Detailed Description
- The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition.
- Recommended Response Action
- Re-insert the fan into the enclosure. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 4201
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
FAN1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 has been inserted.
- Arguments
- arg1 = Fan Sensor Name
- Detailed Description
- The enclosure detected that a fan was inserted.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FAN = Fan Event)
- Severity
- Informational
- Trap/EventID
- 4203
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
FAN1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 has failed.
- Arguments
- arg1 = Fan Sensor Name
- Detailed Description
- The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition.
- Recommended Response Action
- If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (FAN = Fan Event)
- Severity
- Critical
- Trap/EventID
- 4201
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
FAN8500
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Enhanced Cooling Mode is Enabled
- Detailed Description
- Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption.
- Recommended Response Action
- No response action is required.
- Category
- Audit (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN8501
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Enhanced Cooling Mode is Disabled
- Detailed Description
- Disabling Enhanced Cooling Mode allows for reduced power consumption by reducing the maximum speed of the blowers while still providing sufficient blade airflow.
- Recommended Response Action
- No response action is required.
- Category
- Audit (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN8502
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to detect the blower arg1 because the blower may not be optimally operating.
- Arguments
- arg1 = blower name
- Detailed Description
- The current CMC firmware did not detect the blower identified in the message.
- Recommended Response Action
- Make sure that CMC is using the latest firmware, and then retry the operation.
- Category
- Audit (FAN = Fan Event)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN8503
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Chassis was turned off because more than two internal fans stopped functioning.
- Detailed Description
- The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs.
- Recommended Response Action
- Make sure that the Chassis internal fans are functioning. At the command line interface (CLI), enter the following command to identify fans that are not functioning: "racadm getsel". Using the CMC Web GUI, select the chassis, click the Logs tab, and then select Hardware Log. Reinsert or replace fans that are not functioning correctly.
- Category
- Audit (FAN = Fan Event)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN900
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Enhanced Cooling Mode is successfully enabled.
- Detailed Description
- The Enhanced Cooling Mode is successfully enabled.
- Recommended Response Action
- No response action required.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN901
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Enhanced Cooling Mode is successfully disabled.
- Detailed Description
- The Enhanced Cooling Mode is successfully disabled.
- Recommended Response Action
- No response action required.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN902
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Cannot enable the Enhanced Cooling Mode because sufficient power is not available.
- Detailed Description
- The Enhanced Cooling Mode cannot be set because required power is not available.
- Recommended Response Action
- Add PSUs with higher power capability or remove Chassis components such as I/O Modules or servers until the power requirements have been lowered enough to enable the Enhanced Cooling Mode, and then retry the operation.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN903
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis.
- Detailed Description
- The Enhanced Cooling Mode cannot be enabled because an unsupported fan is present in the Chassis.
- Recommended Response Action
- Insert a fan that is supported by the Chassis, and then retry the operation. For a list of fans that are supported by Chassis, see the Chassis Management Controller Users Guide.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN904
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled.
- Detailed Description
- The Enhanced Cooling Mode cannot be enabled because the Maximum Power Conservation Mode is enabled.
- Recommended Response Action
- Disable the Maximum Power Conservation Mode, and then retry the operation. To disable the mode by using CMC Web interface, click Chassis Overview > Power > Configuration. To disable the mode using the RACADM utility, run the command "racadm config -g cfgThermal -o cfgThermalEnhancedCoolingMode 0".
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN905
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Applying fan configuration settings. This may take several seconds.
- Detailed Description
- Applying fan configuration settings. This may take several seconds.
- Recommended Response Action
- No response action required.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN906
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Changes are not made to the current settings.
- Detailed Description
- Changes are not made to the current settings.
- Recommended Response Action
- Make sure that changes are made to the settings and retry the operation.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN907
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Enhanced Cooling Mode feature is already enabled.
- Detailed Description
- The Enhanced Cooling Mode feature is already enabled.
- Recommended Response Action
- No response action required.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN908
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Enhanced Cooling Mode feature is already disabled.
- Detailed Description
- The Enhanced Cooling Mode feature is already disabled.
- Recommended Response Action
- No response action required.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
FAN911
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The attempt to enable the Enhanced Cooling Mode was not successful.
- Detailed Description
- The attempt to enable the Enhanced Cooling Mode (ECM) was not successful because ECM is already enabled or Gen3 fans are not present in the Chassis.
- Recommended Response Action
- Check whether or not the Enhanced Cooling Mode (ECM) is already enabled. Make sure there are Gen3 fans in the Chassis and retry the operation.
- Category
- Configuration (FAN = Fan Event)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable