PowerEdge Servers Error and Event Messages Reference Guide

PDF

FAN—Fan Event Event Messages

FAN0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is less than the lower warning threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing. Fan speeds may have increased to protect the system.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is less than the lower critical threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing. Fan speedsmay have increased to protect the system.
Recommended Response Action
To resolve any temporary issues in communicating with the fans, restart iDRAC. If the issue persists, do the following: 1) Open the chassis cover and check for any cable interference in the fan blades. 2) Remove the fan (as identified in the iDRAC log) from the server and then reinstall in the same slot. 3) Make sure the fan is removed from its connector on the motherboard. 4) Swap the fan with another fan from a different location in the same server. 5) If the issue persists, replace the fan with a new fan. 6) After installing the new fan in the slot, if the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is greater than the upper warning threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is greater than the upper critical threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is outside of range.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 RPM is within range.
Arguments
  • arg1 = number
Detailed Description
Fan speeds may return to normal.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is removed.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 was inserted.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*

FAN0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is present.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is absent.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
LCD Message
Fan <number> is absent. Check Fan.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is disabled.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

FAN0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is enabled.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

FAN0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
The device is not performing optimally. The device may be installed improperly.
Recommended Response Action
Remove and re-install the device at the next scheduled service. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is outside of normal operating range.
Arguments
  • arg1 = name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 RPM is within normal operating range.
Arguments
  • arg1 = name
Detailed Description
The RPM of the fan identified in the message is functioning correctly.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

FAN0018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Enhanced Cooling Mode is not supported for fan arg1.
Arguments
  • arg1 = number
Detailed Description
Enhanced Cooling Mode is not supported by the type of fan identified in the message.
Recommended Response Action
Replace the fan identified in the message with another fan which supports Enhanced Cooling Mode.
Category
System Health (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An incompatibility between operating mode and fan type was corrected for fan arg1.
Arguments
  • arg1 = number
Detailed Description
An incompatibility between operating mode and fan type was corrected for the fan identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is non-functional.
Arguments
  • arg1 = fan name
Detailed Description
The fan identified in the message has failed or it is not installed correctly.
Recommended Response Action
Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Critical
OMSA Event ID
5300
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is offline.
Arguments
  • arg1 = fan name
Detailed Description
The fan identified in the message is removed. However, the fan may be required for optimal system performance.
Recommended Response Action
Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Informational
OMSA Event ID
5303
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor has failed, and the last recorded value by the sensor was arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Critical
OMSA Event ID
5100
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0023

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the arg1 sensor value.
Arguments
  • arg1 = sensor name
Detailed Description
The fan sensor identified in the message has failed or the fan has failed.
Recommended Response Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Warning
OMSA Event ID
5101
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor returned to a normal state with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
OMSA Event ID
5102
OMSA Trap ID
5102
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0025

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The fan identified in the message is not functioning correctly. The fan may be installed incorrectly or may be failing.
Recommended Response Action
Remove and re-install the fan, or replace the fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Warning
OMSA Event ID
5103
OMSA Trap ID
5103
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0026

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor detected an error with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds.
Recommended Response Action
Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Critical
OMSA Event ID
5104
OMSA Trap ID
5104
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0027

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 sensor has failed with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Critical
OMSA Event ID
5105
OMSA Trap ID
5105
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0028

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is inserted.
Arguments
  • arg1 = number
Detailed Description
The fan identified in the message is inserted.Fan speeds may return to normal.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0029

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 is either removed, incorrectly installed, or not present.
Arguments
  • arg1 = number
Detailed Description
The fan identified in the message is either removed, incorrectly installed, or not present. Fan speeds may increase to protect the system.
Recommended Response Action
Install the fan at the next scheduled service.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
LCD Message
Fan <number> is either removed, incorrectly installed, or not present.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 configuration mismatch.
Arguments
  • arg1 = number
Detailed Description
The configuration of fan identified in the message is not matching with the other fans in the server.
Recommended Response Action
Replace the fan with one that has similar configuration during the next scheduled service. For more information about recommended fan configurations, see the iDRAC Users Guide available on the support site.
Category
System Health (FAN = Fan Event)
Severity
Critical
LCD Message
Fan <number> configuration mismatch.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fan arg1 configuration mismatch resolved.
Arguments
  • arg1 = number
Detailed Description
The configuration mismatch of fan identified in the message is successfully resolved. For more information about recommended fan configurations, see the iDRAC Users Guide available on the support site.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The communication with arg1 fan arg2 is lost.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The communication with the fan identified in the message is lost.
Recommended Response Action
If absent, insert a fan. If the fan is present, remove and reseat into the enclosure. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The communication with arg1 fan arg2 is restored.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The communication with the fan identified in the message is restored.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The speed (RPM) of the arg1 fan arg2 is less than the lower warning threshold.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The speed (RPM) of the fan identified in the message is less than the lower warning threshold value.
Recommended Response Action
Remove and reinstall the device during the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Warning
Trap/EventID
2154
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The speed (RPM) of the arg1 fan arg2 is less than the lower critical threshold.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The speed (RPM) of the fan identified in the message is less than the lower critical threshold value.
Recommended Response Action
Remove and reinstall the device during the next scheduled service window. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The speed (RPM) of the arg1 fan arg2 is within the normal operating range.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The speed (RPM) of the fan identified in the message is within the normal operating range.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An issue in the chassis infrastructure hardware or arg1 fan arg2 has affected the chassis thermal control feature.
Arguments
  • arg1 = location
  • arg2 = number
Detailed Description
An issue in the chassis infrastructure hardware or fan module identified in the message has affected the chassis thermal control feature. However, the chassis thermal control feature is temporarily recovered.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0100

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The firmware version of the arg1 fan arg2 is successfully updated.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The firmware version of the fan identified in the message is successfully updated.
Recommended Response Action
No response action is required.
Category
Updates (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update the firmware version of the arg1 fan arg2 because of error code = arg3.
Arguments
  • arg1 = location
  • arg2 = index
  • arg3 = error
Detailed Description
The firmware version of the fan identified in the message cannot be updated because of internal issues.
Recommended Response Action
Manually remove and reinstall the fan during the next scheduled service window. If the issue, persists, contact your service provider.
Category
Updates (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

FAN0200

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 fan arg2 configuration mismatch.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The configuration of the fan identified in the message is not matching with the other fans in the chassis. Some devices may experience varied performance and possible thermal errors depending on the configuration and workload.
Recommended Response Action
Replace the fan with one that matches the configuration and type of fan inside MX7000 at the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0201

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 fan arg2 configuration mismatch resolved.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The configuration mismatch of fan identified in the message is successfully resolved. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0202

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 fan arg2 requires attention for optimal performance.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
A device in the chassis requires a fan type that does not match the configuration of the fan identified in the message. Some devices may experience varied performance and possible thermal errors depending on the configuration, workload, and environment.
Recommended Response Action
Replace the fan with a Gold Grade (Hardware Version 2) fan during the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
Category
System Health (FAN = Fan Event)
Severity
Critical
Trap/EventID
2153
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN0203

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The fan type configuration is corrected for arg1 fan arg2.
Arguments
  • arg1 = location
  • arg2 = index
Detailed Description
The configuration of fan type identified in the message is successfully resolved. For more information about recommended fan configurations, see the MX7000 Users Guide available on the support site.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Informational
Trap/EventID
2155
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN1000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 was removed.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition.
Recommended Response Action
Re-insert the fan into the enclosure. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (FAN = Fan Event)
Severity
Critical
Trap/EventID
4201
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

FAN1001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 has been inserted.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was inserted.
Recommended Response Action
No response action is required.
Category
Storage (FAN = Fan Event)
Severity
Informational
Trap/EventID
4203
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

FAN1002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 has failed.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Storage (FAN = Fan Event)
Severity
Critical
Trap/EventID
4201
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*

FAN8500

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Enhanced Cooling Mode is Enabled
Detailed Description
Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN8501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Enhanced Cooling Mode is Disabled
Detailed Description
Disabling Enhanced Cooling Mode allows for reduced power consumption by reducing the maximum speed of the blowers while still providing sufficient blade airflow.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN8502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect the blower arg1 because the blower may not be optimally operating.
Arguments
  • arg1 = blower name
Detailed Description
The current CMC firmware did not detect the blower identified in the message.
Recommended Response Action
Make sure that CMC is using the latest firmware, and then retry the operation.
Category
Audit (FAN = Fan Event)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN8503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Chassis was turned off because more than two internal fans stopped functioning.
Detailed Description
The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs.
Recommended Response Action
Make sure that the Chassis internal fans are functioning. At the command line interface (CLI), enter the following command to identify fans that are not functioning: "racadm getsel". Using the CMC Web GUI, select the chassis, click the Logs tab, and then select Hardware Log. Reinsert or replace fans that are not functioning correctly.
Category
Audit (FAN = Fan Event)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN900

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Enhanced Cooling Mode is successfully enabled.
Detailed Description
The Enhanced Cooling Mode is successfully enabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN901

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Enhanced Cooling Mode is successfully disabled.
Detailed Description
The Enhanced Cooling Mode is successfully disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN902

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cannot enable the Enhanced Cooling Mode because sufficient power is not available.
Detailed Description
The Enhanced Cooling Mode cannot be set because required power is not available.
Recommended Response Action
Add PSUs with higher power capability or remove Chassis components such as I/O Modules or servers until the power requirements have been lowered enough to enable the Enhanced Cooling Mode, and then retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN903

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because an unsupported fan is present in the Chassis.
Recommended Response Action
Insert a fan that is supported by the Chassis, and then retry the operation. For a list of fans that are supported by Chassis, see the Chassis Management Controller Users Guide.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN904

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because the Maximum Power Conservation Mode is enabled.
Recommended Response Action
Disable the Maximum Power Conservation Mode, and then retry the operation. To disable the mode by using CMC Web interface, click Chassis Overview > Power > Configuration. To disable the mode using the RACADM utility, run the command "racadm config -g cfgThermal -o cfgThermalEnhancedCoolingMode 0".
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN905

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Applying fan configuration settings. This may take several seconds.
Detailed Description
Applying fan configuration settings. This may take several seconds.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN906

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Changes are not made to the current settings.
Detailed Description
Changes are not made to the current settings.
Recommended Response Action
Make sure that changes are made to the settings and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN907

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Enhanced Cooling Mode feature is already enabled.
Detailed Description
The Enhanced Cooling Mode feature is already enabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN908

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Enhanced Cooling Mode feature is already disabled.
Detailed Description
The Enhanced Cooling Mode feature is already disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FAN911

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The attempt to enable the Enhanced Cooling Mode was not successful.
Detailed Description
The attempt to enable the Enhanced Cooling Mode (ECM) was not successful because ECM is already enabled or Gen3 fans are not present in the Chassis.
Recommended Response Action
Check whether or not the Enhanced Cooling Mode (ECM) is already enabled. Make sure there are Gen3 fans in the Chassis and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable