PowerEdge Servers Error and Event Messages Reference Guide

PDF

FCD—Feature Card Event Messages

FCD8500

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to apply the arg1 configuration. The affected servers (slot arg2) are not turned off.
Arguments
  • arg1 = configuration name
  • arg2 = slot number
Detailed Description
The server specified in the message must be turned off or the server slot must be empty before changing the FlexAddress configuration.
Recommended Response Action
Turn off the server and retry the operation.
Category
Audit (FCD = Feature Card)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The feature is deactivated: arg1.
Arguments
  • arg1 = feature name
Detailed Description
The FlexAddress, FlexAddress+ or extended storage feature is deactivated. Turn chassis off and remove the feature card.
Recommended Response Action
Turn chassis OFF and remove card. Alternately, to repair the card, perform Repair by navigating to the CMC GUI -> Chassis Controller -> Flash Media page.
Category
Audit (FCD = Feature Card)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The feature is activated in the chassis: arg1
Arguments
  • arg1 = feature name
Detailed Description
Chassis already has the feature identified in the message activated. Only one instance of a feature can be activated at a time. If the feature must be activated on the new card, it must be deactivated before activating.
Recommended Response Action
No response action is required.
Category
Audit (FCD = Feature Card)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8504

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The feature was previously activated on another chassis.
Detailed Description
The card was installed and activated on another chassis. To use this card, it must be deactivated (uninstalled) on the other chassis.
Recommended Response Action
Remove the card and install it on the chassis where the feature is activated.
Category
Audit (FCD = Feature Card)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8505

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The features cannot be deactivated when the chassis is turned on.
Detailed Description
Features cannot be deactivated when the chassis is turned on.
Recommended Response Action
Turn off the chassis via the Web interface or RACADM command line interface before deactivating the feature. To turn off the chassis using Racadm type "racadm chassisaction -m chassis powerdown". To deactivate the feature using RACADM, type "racadm <feature> -d" where <feature> is the name of the feature to be deactivated.
Category
Audit (FCD = Feature Card)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8531

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to activate the arg1. The chassis service tag is unavailable.
Arguments
  • arg1 = feature name
Detailed Description
The CMC is not responding. The chassis has the factory-programmed service tag.
Recommended Response Action
Contact your service provider.
Category
Audit (FCD = Feature Card)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

FCD8532

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to activate the FlexAddress feature because the SD card in which the FlexAddress is stored is corrupted.
Detailed Description
The FlexAddress feature cannot be activated because the SD card in which the FlexAddress (pwwn_mac.xml) or FlexAddressPlus file (pwwn_mac_ext.xml) is stored is corrupted with invalid data.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Audit (FCD = Feature Card)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\