PowerEdge Servers Error and Event Messages Reference Guide
FLDC—Fluid Cache Event Messages
FLDC1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The journal mirror at path = arg1 is available.
- Arguments
- arg1 = World Wide Name
- Detailed Description
- The entry in the journal for the device identified in the message with the WWN (World Wide Name) is available.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2700
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The following journal mirror is being replaced: File Path Name = arg1.
- Arguments
- arg1 = file path
- Detailed Description
- The journal mirror at the reported file path is being replaced. This event is a notification that the journal mirror replacement is now complete.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2701
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Cache flushing has started for the virtual disk with WWN = arg1 and path = arg2.
- Arguments
- arg1 = World Wide Name
- arg2 = device pathname
- Detailed Description
- The cache flushing operation has started for the virtual disk identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2875
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Cache flushing has completed for the virtual disk with WWN = arg1 and path = arg2.
- Arguments
- arg1 = World Wide name
- arg2 = device pathname
- Detailed Description
- The cache flushing operation has completed for the virtual disk identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2876
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cache device arg1 with WWN = arg2 and path = arg3 is registered.
- Arguments
- arg1 = physical disk name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- The cache device identified in the message is registered by the Fluid Cache.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2903
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cache device arg1 with WWN = arg2 and path = arg3 is removed.
- Arguments
- arg1 = physical disk Name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- The cache device identified in the message is removed from the Fluid Cache configuration.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2904
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cache device arg1 with WWN = arg2 and path = arg3 is being removed.
- Arguments
- arg1 = physical disk Name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- The cache device identified in the message is being removed from the Fluid Cache configuration.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2905
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching is being removed for the arg1 with WWN = arg2 and path = arg3.
- Arguments
- arg1 = virtual disk name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- Caching is being removed for the virtual disk identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2906
- OMSA Trap ID
- 120100;150100;160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching is enabled on the arg1 with wwn = arg2 and path = arg3.
- Arguments
- arg1 = virtual disk name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- Caching is enabled on the virtual disk identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2907
- OMSA Trap ID
- 120100;150100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching is disabled for the arg1 with WWN = arg2 and path = arg3.
- Arguments
- arg1 = virtual disk name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- The operation to disable caching is successful. Caching is disabled for the virtual disk identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2910
- OMSA Trap ID
- 120100;150100;160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cached LUN with WWN = arg1 and path = arg2 for arg3 has had a failure.
- Arguments
- arg1 = World Wide Name
- arg2 = device pathname
- arg3 = virtual disk name
- Detailed Description
- The cached LUN identified in the message has had a failure to successfully perform a read or write operation. The user application should now be seeing I/O failures when trying to read or write to the Fluid Cache device at the path identified in the message.
- Recommended Response Action
- Contact your service provider to diagnose the cause and assist in recovery process.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2911
- OMSA Trap ID
- 140400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Replication of the cache device arg1 with WWN = arg2 and path = arg3 is complete.
- Arguments
- arg1 = physical device name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- Replication of the cache device identified in the message is complete.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2912
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Recovery of the cache device arg1 with wwn = arg2 and path = arg3 is complete.
- Arguments
- arg1 = physical disk name
- arg2 = World Wide Name
- arg3 = device pathname
- Detailed Description
- The recovery of the cache device identified in the message complete.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2913
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A valid permanent license is installed for Fluid Cache.
- Detailed Description
- A valid permanent license is installed for Fluid Cache.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2914
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A license has been installed for Fluid Cache.
- Detailed Description
- A license has been installed for Fluid Cache.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2920
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A license has been removed for Fluid Cache.
- Detailed Description
- A license has been removed for Fluid Cache.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2921
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- All cache devices have been found and registered for Fluid Cache.
- Detailed Description
- All cache devices have been found and registered for Fluid Cache.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2924
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage device with WWN = arg1 and path = arg2is in unknown state.
- Arguments
- arg1 = wwn name
- arg2 = path name
- Detailed Description
- The storage device identified in the message is in unknown state.
- Recommended Response Action
- Service is required. Contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2909
- OMSA Trap ID
- 120300;150300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The journal mirror entry with WWN = arg1 is not accessible.
- Arguments
- arg1 = World Wide Name
- Detailed Description
- The device identified in the message having the journal mirror entry with given WWN (World Wide Name) is not accessible. A portion of an SSD is used for journal content. To assure consistency, the journal content is written into two other SSDs. These copies are journal mirrors. If the journal content cannot be written to any of the journal mirrors, then this event is signaled. It is a warning because the FLDC code will then attempt to choose another SSD to be a journal mirror.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2702
- OMSA Trap ID
- 160300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The associated server of the Cache Device arg1 with WWN = arg2 is not configured.
- Arguments
- arg1 = physical disk name
- arg2 = World Wide Name
- Detailed Description
- The cache device identified in the message with given WWN does not exist in the Fluid Cache configuration.
- Recommended Response Action
- To identify the cause of the configuration inconsistency, contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2874
- OMSA Trap ID
- 90300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1023
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fluid Cache is running on an evaluation license and the evaluation license expires in arg1 days.
- Arguments
- arg1 = days
- Detailed Description
- Fluid Cache is currently running on an evaluation license and the evaluation license expires in the number of days identified in message.
- Recommended Response Action
- A permanent license for Fluid Cache should be purchased for continued service.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Informational
- OMSA Event ID
- 2916
- OMSA Trap ID
- 160100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching was enabled in write-back mode, but it is currently operating in write-through mode.
- Detailed Description
- Caching was enabled in write-back mode but currently it is operating in write-through mode because the fluid Cache Pool has one PCIe-SSD.
- Recommended Response Action
- Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2930
- OMSA Trap ID
- 120300;150300;160300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching was enabled in write-back or write-through mode, it is currently operating in pass-through mode.
- Detailed Description
- Caching was enabled in write-back mode or write through mode, but currently it is operating in write-through mode because fluid Cache Pool has no PCIe-SSD device.
- Recommended Response Action
- Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2931
- OMSA Trap ID
- 120300;150300;160300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching is no longer degraded to write-through mode and is now operating in write-back mode for Fluid Cache.
- Detailed Description
- The caching mode has been restored back to write-back mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2932
- OMSA Trap ID
- 120300;150300;160300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching is no longer degraded to pass-through mode and is now operating in its configured mode for Fluid Cache.
- Detailed Description
- The caching mode has been restored back to the configured mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration.
- Recommended Response Action
- No response action is required.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Warning
- OMSA Event ID
- 2933
- OMSA Trap ID
- 120300;150300,160300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- OMSS Connection to Fluid Cache service is no longer present.
- Detailed Description
- The communications connection between OMSS and the Fluid Cache service is no longer present.
- Recommended Response Action
- To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is running. To verify the service run the following command: "fldc --status". 2) Re-establish the connect by running the following command: :"omconfig storage fluidcache action=connect".
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2699
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- There are not enough journal mirrors available for Fluid Cache to operate.
- Detailed Description
- The message indicates that there are not enough journal mirrors available for Fluid Cache to operate. Make sure that there are at least two journal mirrors that are accessible. Activate either one or more failed cache devices or use the fldc_restore utility to rebuild the node.
- Recommended Response Action
- Contact your service provider to diagnose the cause and assist in recovery process.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2703
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cluster ID in the journal does not match the cluster ID in the configuration file for Fluid Cache.
- Detailed Description
- An Inconsistency was found in Fluid Cache configuration data.
- Recommended Response Action
- Service is required. Contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2704
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The journal could not be read or written to for Fluid Cache.
- Detailed Description
- Unable to access redundant Fluid Cache configuration information.
- Recommended Response Action
- Service is required. Contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2705
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The cache device with WWN = arg1 and path = arg2is no longer functional.
- Arguments
- arg1 = wwn name
- arg2 = path name
- Detailed Description
- The PCIeSSD cache device identified in the message is no longer functional.
- Recommended Response Action
- Replace the non-functional PCIe SSD.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2900
- OMSA Trap ID
- 90400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage device WWN = arg1 and path = arg2 is either inaccessible or no longer functional.
- Arguments
- arg1 = wwn name
- arg2 = path name
- Detailed Description
- The message indicates that the storage device is either inaccessible or is no longer functional.
- Recommended Response Action
- If the virtual disk is inaccessible, restore accessibility by bringing the virtual disk back online. After the virtual disk is accessible, run the following command to reactivate disk, "omconfig storage vdisk action=reactivate controller=id vdisk=id devicename=<string>". If the device is no longer functional, replace it.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2901
- OMSA Trap ID
- 120400;150400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A valid license is not installed for Fluid Cache.
- Detailed Description
- A valid license is not installed for Fluid Cache.
- Recommended Response Action
- Install a valid Fluid Cache license. For more information, contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2915
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Configuration changes are not allowed, because Fluid cache is running on an expired evaluation license (Expired days: arg1).
- Arguments
- arg1 = number of days
- Detailed Description
- Configuration changes are not allowed because Fluid Cache is running on an expired evaluation license. The message also indicates the number of days that Fluid Cache has been running with an expired license (maximum 30 days after expiration are allowed).
- Recommended Response Action
- Install a valid Fluid Cache license. For more information, contact your service provider.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2917
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Caching functionality is disabled because Fluid cache is running on an expired evaluation license (Expired days: arg1).
- Arguments
- arg1 = number of days
- Detailed Description
- Caching functionality is disabled because Fluid cache is running on an expired evaluation license. The message also indicates the number of days that Fluid Cache has been running with an expired license (maximum 30 days after expiration are allowed).
- Recommended Response Action
- Install a permanent Fluid Cache license.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2918
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Configuration changes are disabled, because Fluid cache is running on an expired or invalid license.
- Detailed Description
- Configuration changes are disabled, because Fluid cache is running on an expired or invalid license.
- Recommended Response Action
- Install a permanent Fluid Cache license.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2919
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1038
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- There is not enough memory capacity to run necessary services for Fluid Cache.
- Detailed Description
- There is not enough memory capacity to run necessary services for Fluid Cache.
- Recommended Response Action
- The minimum memory required to run Fluid Cache for DAS is 16 GB. For optimum operation, recommendation is to install 32 GB of RAM.
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2922
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
FLDC1039
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more cache devices are missing, resulting in Fluid Cache to be unresponsive.
- Detailed Description
- One or more cache devices are missing and the cache is unresponsive.
- Recommended Response Action
- Insert the missing cache device. If the cache device was unplugged, reactivate it. Reactivate a cache device by running the following command: "omconfig storage pciessd action=reactivate subsystem=id pciedevice=<PDISKID>".
- Category
- Storage (FLDC = Fluid Cache)
- Severity
- Critical
- OMSA Event ID
- 2923
- OMSA Trap ID
- 160400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message