PowerEdge Servers Error and Event Messages Reference Guide

PDF

HTR—Heater Manager Event Messages

HTR0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Heater Manager is detected. The firmware version is arg1.
Arguments
  • arg1 = VALUE
Detailed Description
Heater Manager having the firmware version identified in the message is detected.
Recommended Response Action
No response action required.
Category
Configuration (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The heating functionality of Heater Manager is turned arg1 before starting the server.
Arguments
  • arg1 = On/Off
Detailed Description
The heating functionality of Heater Manager is either turned on or turned off before starting the server.
Recommended Response Action
No response action is required.
Category
Configuration (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Heater Manager logged information events with the following value: arg1.
Arguments
  • arg1 = value
Detailed Description
The Heater Manager logged information events with the value identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Heater Manager logged warning events with the following value : arg1.
Arguments
  • arg1 = value
Detailed Description
The Heater Manager logged warning events with the value identified in the message.
Recommended Response Action
Immediately replace the Heater Manager Module with a good module.
Category
Configuration (HTR = Heater Manager)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Heater Manager logged failure events with the following value : arg1.
Arguments
  • arg1 = value
Detailed Description
The Heater Manager logged failure events with the value identified in the message.
Recommended Response Action
Immediately replace the Heater Manager Module with a good module.
Category
Configuration (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health status of Heater Manager is OK.
Detailed Description
The health status of Heater Manager is OK.
Recommended Response Action
No response action is required.
Category
Configuration (HTR = Heater Manager)
Severity
Informational
Trap/EventID
11467
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of Heater Manager is in Warning state.
Detailed Description
The health of Heater Manager is in Warning state.
Recommended Response Action
Immediately replace the Heater Manager Module with a good module.
Category
Configuration (HTR = Heater Manager)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of Heater Manager is in Critical state.
Detailed Description
The health of Heater Manager is in Critical state.
Recommended Response Action
Immediately replace the Heater Manager Module with a good module.
Category
Configuration (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Heater Manager that has the following unique identification number is detected: arg1.
Arguments
  • arg1 = VALUE
Detailed Description
Heater Manager that has a unique identification number is detected.
Recommended Response Action
No response action is required.
Category
Configuration (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The number of arg1logs is more than the threshold value of arg2.
Arguments
  • arg1 = Warning/Error
  • arg2 = maxLogValue
Detailed Description
The health status of heater Manager is critical. The number of logs of the identified log type is more than the threshold value.
Recommended Response Action
Immediately replace the Heater Manager Module with a good module.
Category
Configuration (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of Heater Manager is in the Critical state.
Detailed Description
The health of Heater Manager is in the Critical state. The health of a Heater Manager changes to the Critical state when any of the heaters health changes to Critical or the heating subsystems infrastructure changes to Critical.
Recommended Response Action
Review the corresponding additional message(s) for the cause of the Critical state and its recommended response action.
Category
Configuration (HTR = Heater Manager)
Severity
Critical
Trap/EventID
11465
LCD Message
The health of Heater Manager is in the Critical state.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to upgrade the Heater Manager Subsystem firmware version because the heating status of one or more heater zones are enabled (ON).
Detailed Description
The firmware version of the Heater Manager Subsystem was not upgraded because the heating status of one or more heater zones are enabled (ON).
Recommended Response Action
Make sure that the heating status of all the heater zones are disabled (Off) and retry the operation.
Category
Updates (HTR = Heater Manager)
Severity
Warning
Trap/EventID
7370
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Successfully upgraded the Heater Manager Subsystem firmware version.
Detailed Description
The firmware version of the Heater Manager Subsystem is upgraded successfully.
Recommended Response Action
No response action is required.
Category
Updates (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to upgrade the Heater Manager Subsystem firmware version. Error=arg1, (arg2).
Arguments
  • arg1 = ErrorNum
  • arg2 = ErrorDescription
Detailed Description
The firmware version of the Heater Manager Subsystem was not upgraded because of internal communication errors.
Recommended Response Action
Retry the firmware update operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Updates (HTR = Heater Manager)
Severity
Warning
Trap/EventID
7370
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The heater in the zone arg1 is unable to heat in the pre-heating cycle.
Arguments
  • arg1 = ZoneName
Detailed Description
The heater in the zone identified in the message is unable to heat in the pre-heating cycle.
Recommended Response Action
For specific issue-related information, see the Lifecycle Log data, and then initiate necessary corrective action.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Trap/EventID
3273
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The heater in the arg1 zone is heated in the pre-heating cycle.
Arguments
  • arg1 = ZoneName
Detailed Description
The heater in the zone identified in the message is heated in the pre-heating cycle.
Recommended Response Action
No response action is required.
Category
System Health (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 firmware is corrupted. However, an automatic recovery operation has started that may take a few minutes.
Arguments
  • arg1 = subsystem
Detailed Description
Firmware of the subsystem identified in the message is corrupted. However, an automatic recovery operation has started that may take a few minutes.
Recommended Response Action
No response action is required. Wait till the automatic recovery operation is completed.
Category
System Health (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The corrupted firmware of arg1 is restored.
Arguments
  • arg1 = subsystem
Detailed Description
Corrupted firmware of the subsystem identified in the message is recovered. The subsystem is now functioning.
Recommended Response Action
No response action is required.
Category
System Health (HTR = Heater Manager)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to recover the firmware of arg1. The subsystem is not communicating with iDRAC.
Arguments
  • arg1 = subsystem
Detailed Description
Corrupted firmware of the subsystem identified in the message cannot be recovered. The subsystem is not communicating with iDRAC.
Recommended Response Action
If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unrecoverable hardware issue with Error Code arg1 is detected in the Heater Manager Subsystem.
Arguments
  • arg1 = Code
Detailed Description
An unrecoverable hardware issue is detected in the Heater Manager Subsystem.
Recommended Response Action
Restart the server. If the issue persists then provide this iDRAC Lifecycle log to the Technical Support team and do not use the server anymore until the issue is resolved.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A software issue with Error Code arg1 is detected in the Heater Manager Subsystem.
Arguments
  • arg1 = Code
Detailed Description
A software issue is detected in the Heater Manager Subsystem.
Recommended Response Action
Restart the server. If the issue persists then provide this iDRAC Lifecycle log to the Technical Support team and do not use the server anymore until the issue is resolved.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unrecoverable hardware issue with Error Code arg1 is detected in the Heater Manager Subsystem.
Arguments
  • arg1 = Code
Detailed Description
An unrecoverable hardware issue is detected in the Heater Manager Subsystem.
Recommended Response Action
Power off the server and provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The required sensor arg1 for the arg2 zone is not present.
Arguments
  • arg1 = sensorNum
  • arg2 = zoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. A sensor for the identified zone in the message is not present.
Recommended Response Action
Power off the server and ensure that the sensor cable is properly connected to the zone identified in the message. If the issue persists then provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The arg1 zone has reported a high-temperature error.
Arguments
  • arg1 = ZoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. The identified zone in the message has reported a high-temperature error.
Recommended Response Action
Power off the server and ensure that the heater cable assembly for the identified zone is properly attached and not loose or hanging. If the heater cable assembly is attached properly then provide this iDRAC Lifecycle log to the Technical Support team. Do not use the server in temperatures less than zero degrees Celsius.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0051

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The required heater for arg1 zone is not present.
Arguments
  • arg1 = zoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. The required heater for the zone identified in the message is not present.
Recommended Response Action
Power off the server and ensure that the heater for the zone identified in the message is connected. If the heater cable is connected properly then provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0052

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The heater control for arg1 zone has stopped functioning.
Arguments
  • arg1 = ZoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. The heater of the zone identified in the message has stopped functioning.
Recommended Response Action
Power off the server and provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0053

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The heater control for arg1 zone is not working correctly.
Arguments
  • arg1 = ZoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. The heater of the zone identified in the message is not working correctly.
Recommended Response Action
Power off the server and provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0054

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware mismatch is identified for the arg1 zone in the Heater Manager Subsystem.
Arguments
  • arg1 = ZoneName
Detailed Description
A hardware mismatch is identified for the zone in the Heater Manager Subsystem.
Recommended Response Action
Power off the server and ensure that the heater and sensor cable assembly for zone identified in the message are plugged into the correct connectors and the sensors are properly positioned. If the heater and sensor cable assembly is properly positioned then provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0055

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The heater for arg1 zone may not be heating correctly.
Arguments
  • arg1 = ZoneName
Detailed Description
A hardware failure has occurred in the Heater Manager Subsystem. The heater for the zone identified in the message may not be heating correctly.
Recommended Response Action
Power off the server and ensure that the heater and sensor cable assembly for zone identified in the message are plugged into the correct connectors and the sensor cable assembly is properly positioned. If the issue persists then provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0060

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue has occurred in the Heater Manager Subsystem. The sensor arg1 in the arg2 zone is short circuited.
Arguments
  • arg1 = SensorNum
  • arg2 = ZoneName
Detailed Description
A hardware issue has occurred in the Heater Manager Subsystem. The sensor identified in the message is short circuited.
Recommended Response Action
Power off the server and replace the sensor cable assembly. If the issue persists then provide this iDRAC Lifecycle log to the Technical Support team.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0067

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue occurred in the Heater Manager Subsystem during a Factory Test operation.
Detailed Description
A hardware issue occurred in the Heater Manager Subsystem during a Factory Test operation.
Recommended Response Action
Power off the server and check for other heater subsystem issues in the iDRAC Lifecycle log data.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HTR0070

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware issue is detected in the Heater Manager subsystem. The required sensor cable arg1 for the arg2 zone is removed or uninstalled.
Arguments
  • arg1 = CableNum
  • arg2 = ZoneName
Detailed Description
A hardware issue is detected in the Heater Manager subsystem. A sensor cable for the zone identified in the message is removed or uninstalled.
Recommended Response Action
Power off the server and ensure that the sensor cable assembly for the zone identified in the message is fully connected to the correct connector. To identify the cable, see the service information printed in the label on the chassis cover or the Cable Routing section in the Installation and Service Manual (ISM) of the respective server model available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HTR = Heater Manager)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable