PowerEdge Servers Error and Event Messages Reference Guide

PDF

HWC—Hardware Config Event Messages

HWC0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation as there is no response from iDRAC.
Detailed Description
The error is caused due to iDRAC failure.
Recommended Response Action
1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord and turn on the system.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect vFlash SD card.
Detailed Description
The vFlash SD Card is either not present or not correctly inserted.
Recommended Response Action
Insert the vFlash SD card or reinsert the vFlash SD card, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Successfully initialized vFlash SD card.
Detailed Description
The vFlash SD card was successfully initialized.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to initialize vFlash SD card.
Detailed Description
The vFlash SD card is incorrectly inserted, the vFlash SD card is faulty, or there is an iDRAC communication failure.
Recommended Response Action
Reinsert or replace the vFlash SD card, or reset iDRAC, and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal error while retrieving update information.
Detailed Description
Internal error while retrieving firmware version for the currently installed components. For more information about the failure, see Lifecycle Log.
Recommended Response Action
1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to save vFlash SD card settings.
Detailed Description
If a vFlash SD card is not present in the system or if the card is locked, Lifecycle Controller cannot save the settings.
Recommended Response Action
Insert the vFlash SD card or unlock the vFlash SD card and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to load vFlash SD card settings.
Detailed Description
Lifecycle Controller is unable to retrieve vFlash SD card information from iDRAC.
Recommended Response Action
Reinsert the vFlash SD card and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to communicate with iDRAC.
Detailed Description
An internal error occurred while communicating with iDRAC.
Recommended Response Action
Exit the wizard and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to enable vFlash SD card.
Detailed Description
The vFlash SD card is missing or not inserted correctly. iDRAC is not able to enable vFlash SD card.
Recommended Response Action
Reinsert the vFlash SD card and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Invalid folder name or USB drive not found.
Detailed Description
Operation failed because the folder name entered is incorrect or the USB drive is disconnected.
Recommended Response Action
Enter a valid folder name or attach the USB drive and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Insufficient space to copy the file to the USB drive.
Detailed Description
The USB drive does not have sufficient free space to copy the file.
Recommended Response Action
Make sure the USB drive has sufficient free space before retrying the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to write to the USB drive.
Detailed Description
The USB drive is write protected.
Recommended Response Action
Remove write protection on the USB drive before retrying the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to copy the file to USB drive.
Detailed Description
The USB drive is disconnected or is not readable.
Recommended Response Action
Remove and reinsert the USB drive and retry the operation. If the problem persists, restart the system and retry.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect vFlash SD card.
Detailed Description
The import operation failed because the vFlash SD card is missing or disabled.
Recommended Response Action
Make sure the vFlash SD card is inserted and enabled before retrying the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
iDRAC not responding.
Detailed Description
iDRAC has encountered a hardware error.
Recommended Response Action
Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord. 2) Wait five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
iDRAC communication failure.
Detailed Description
Lifecycle Controller is unable to communicate with iDRAC.
Recommended Response Action
Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord. 2) Wait five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to start Lifecycle Controller because Lifecycle Controller cannot communicate with iDRAC, because of internal issues arg1.
Arguments
  • arg1 = error code
Detailed Description
Cannot start Lifecycle Controller because Lifecycle Controller is unable to communicate with iDRAC because of internal issues.
Recommended Response Action
Issue is because of an internal error. To resolve the issue:1) Turn off the server and disconnect the power cord. 2) Wait for 10 seconds, reconnect the power cord, turn on the server, and retry starting Lifecycle Controller by pressing F10 when the company logo is displayed. 3) If the issue not resolved, update iDRAC firmware to the latest version, and then retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC0018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to load the necessary drivers because of internal issues between iDRAC and Lifecycle Controller arg1.
Arguments
  • arg1 = error code
Detailed Description
The necessary drivers cannot be loaded because of internal issues between iDRAC and Lifecycle Controller.
Recommended Response Action
Issue is because of an internal error. To resolve the issue:1) Turn off the server and disconnect the power cord. 2) Wait for 10 seconds, reconnect the power cord, turn on the server, and retry starting Lifecycle Controller by pressing F10 when the company logo is displayed. 3) If the issue not resolved, update iDRAC firmware to the latest version, and then retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is present.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is absent.
Arguments
  • arg1 = name
Detailed Description
The absent device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Re-install or reconnect the hardware.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <name> is absent. Check hardware
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is disabled.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If device disabled unexpectedly, re-enable device.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is enabled.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage adapter is present.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage adapter is absent.
Detailed Description
The storage adapter may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Install storage adapter.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The storage adapter is absent. Check hardware
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage adapter is disabled.
Detailed Description
No detailed description available.
Recommended Response Action
If adapter disabled unexpectedly, re-enable the storage adapter.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage adapter is enabled.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The backplane is present.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The backplane is absent.
Detailed Description
The backplane may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The backplane is absent. Check hardware
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The backplane is disabled.
Detailed Description
No detailed description available.
Recommended Response Action
If disabled unexpectedly, re-enable backplane.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The backplane is enabled.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The USB cable is present.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The USB cable is absent.
Detailed Description
The USB cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The USB cable is absent. Check cable
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The mezzanine card arg1 is present.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The mezzanine card arg1 is absent.
Arguments
  • arg1 = number
Detailed Description
The mezzanine card may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC1100

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 was installed in slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is removed from slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is installed in an invalid slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The peripheral sled identified in the message is installed in the unsupported slot identified in the message.
Recommended Response Action
Install the Storage sled in a supported slot and retry the operation. For information about the supported sleds and slots, see the Users Guide available at the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1103

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 installed in an invalid slot arg2 is removed.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The peripheral sled identified in the message is removed from the unsupported slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 installed in slot arg2 is not supported by the chassis.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The peripheral sled identified in the message that is inserted in the slot identified in the message is not supported by the chassis or the current CMC/MM firmware version.
Recommended Response Action
Make sure that the peripheral sled identified in the message is supported by the chassis and the CMC/MM. For information about the supported sleds and firmware versions, see the System Manual available at the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1105

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unsupported arg1 in slot arg2 is removed.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The peripheral sled identified in the message is removed from the unsupported slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1107

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Configuration validation has been arg1.
Arguments
  • arg1 = state
Detailed Description
Configuration Validation has been enabled or disabled as indicated in the message.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1108

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system configuration arg1 has been added to the configuration profile for system validation.
Arguments
  • arg1 = config ID
Detailed Description
The system configuration identified in the message has been added to the configuration profile for system validation.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1109

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The hardware or software component arg1 has been added to the configuration profile arg2 for validating the system configuration.
Arguments
  • arg1 = component Name
  • arg2 = config ID
Detailed Description
The hardware or software component has been added to the configuration profile identified in the message for validating the system configuration.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1110

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The System Configuration Check operation has detected a change in the configuration from Config arg1 to arg2.
Arguments
  • arg1 = old Config ID
  • arg2 = new Config ID
Detailed Description
The System Configuration Check operation has detected a change in the configuration as identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1200

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled arg1 is inserted in slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The sled identified in the message is inserted in the slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1201

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled arg1 is removed from slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The sled identified in the message is removed from the slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1202

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 was installed in slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1203

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is removed from slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC1204

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled is inserted in the sled slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
The sled is inserted in the sled slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1205

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled is removed from the sled slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
The sled is removed from the sled slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1206

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of sled in the sled slot arg1 is Good.
Arguments
  • arg1 = slot number
Detailed Description
The health of sled in the sled slot identified in the message is Good.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1207

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of sled in the sled slot arg1 is in Warning state.
Arguments
  • arg1 = slot number
Detailed Description
The health of sled in the sled slot identified in the message is in Warning state.
Recommended Response Action
In the Chassis Subsystem under the overview page of the Management Module graphical user interface (GUI), look for the System.Modular subsystem with the slot number provided in the message to get more details. For more information, see the Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1208

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of sled in the sled slot arg1 is in Critical state.
Arguments
  • arg1 = slot number
Detailed Description
The health of sled in the sled slot identified in the message is in Critical state.
Recommended Response Action
In the Chassis Subsystem under the overview page of the Management Module graphical user interface (GUI), look for the System.Modular subsystem with the slot number provided in the message to get more details. For more information, see the Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1209

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled in the sled slot arg1 is not supported by the Management Module.
Arguments
  • arg1 = slot number
Detailed Description
The sled in the sled slot identified in the message is not recognized by the Manage Module hardware. The sled may have a hardware error or may be incompatible with this version of the Management Module.
Recommended Response Action
Verify the sled hardware is functioning. If required, update the firmware version of the Management Module to one that supports the sled. For more information, see the Users Guide available on the support site. If the issue, persists, replace the sled.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1210

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled in the sled slot arg1 cannot communicate to the Chassis because of internal issues.
Arguments
  • arg1 = slot number
Detailed Description
The sled in the sled slot identified in the message cannot communicate to the Chassis because of internal issues.
Recommended Response Action
Do any one of the following: 1) Wait for the iDRAC network to start and retry the operation. 2) Turn off the sled, wait for five seconds, and then turn on the sled. 3) If the issue persists, remove the sled, wait for five seconds, and then reinsert the sled.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1211

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to turn on the sled in the sled slot arg1 because of insufficient power.
Arguments
  • arg1 = slot number
Detailed Description
The sled in the sled slot identified in the message cannot turn on because of insufficient power.
Recommended Response Action
Do any one of the following and retry the operation: 1) Add power supply units (PSUs) to the chassis. 2) Enter the Management Module GUI enter the power settings and increase the power limit in the chassis.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1212

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The virtual reseat operation is initiated for the sled in the sled slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
The virtual reseat operation is initiated for the sled in the sled slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1213

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sled in the sled slot arg1 cannot turn off on time because the chassis has undergone a forceful shutdown.
Arguments
  • arg1 = slot number
Detailed Description
The sled in the sled slot identified in the message is not turned off on time, because the chassis has undergone a forceful shutdown.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1214

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch is detected in the fabric arg1 available on the server in slot arg2.
Arguments
  • arg1 = fabric name
  • arg2 = server slot
Detailed Description
A fabric mismatch is detected in the fabric available on the server in slot identified in the message.
Recommended Response Action
Check the chassis fabric type in the Manage Module graphical user interface (GUI) and compare against the I/O module or mezzanine card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1215

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in the slot arg1 has a power issue and is automatically turned off.
Arguments
  • arg1 = slot number
Detailed Description
The peripheral sled in the slot identified in the message has a power issue and is automatically turned off.
Recommended Response Action
Contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1216

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in the slot arg1 is opened for an extended period of time.
Arguments
  • arg1 = slot number
Detailed Description
The peripheral sled in the slot identified in the message is opened for an extended period of time.
Recommended Response Action
Close the sled if in the opened position. If in the closed position and the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1217

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The compute sled in arg1 had storage mappings and has been replaced.
Arguments
  • arg1 = slot number
Detailed Description
The compute sled in the slot identified in the message had storage mappings which may not be appropriate for the replacement sled. The current sled will not be powered on until further action is taken.
Recommended Response Action
Check if the storage mappings are correct for the new sled and either accept the mappings or clear them as appropriate.
Category
Storage (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1218

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The compute sled in arg1 had shared storage mappings and has been replaced by a sled which cannot support shared mappings.
Arguments
  • arg1 = slot number
Detailed Description
The compute sled in the specified slot has shared storage mappings which the storage controller in the new sled does not support. The current sled will not be powered on until further action is taken.
Recommended Response Action
Replace the specified sled with one whos storage controller supports shared mapping or clear the mappings as appropriate.
Category
Storage (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1219

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in the slot arg1 is open.
Arguments
  • arg1 = slot number
Detailed Description
The peripheral sled in the slot identified in the message is open.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1220

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in the slot arg1 is closed.
Arguments
  • arg1 = slot number
Detailed Description
The peripheral sled in the slot identified in the message is closed.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1223

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to confirm the host server in slot arg1 as powered off within the expected time period, during a graceful shutdown.
Arguments
  • arg1 = slot number
Detailed Description
The host server in the slot identified in the message did not confirm it has powered off during the graceful shutdown operation.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1224

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The host server in slot arg1 did not complete its Persistent Memory save within the expected time period, during a graceful shutdown.
Arguments
  • arg1 = slot number
Detailed Description
The host server in the slot identified in the message did not complete its Persistent Memory save within the expected time period, during a graceful shutdown.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1225

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in the slot arg1 has an internal cable disconnected or is missing required expanders.
Arguments
  • arg1 = slot number
Detailed Description
One or more cables in the peripheral sled are not correctly connected or required expanders are not installed which can cause loss of functionality.
Recommended Response Action
Remove the peripheral sled and check internal cables and required expanders are properly installed.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1226

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in slot arg1 has lost redundancy.
Arguments
  • arg1 = slot number
Detailed Description
The data path redundancy to the peripheral sled is degraded due to the loss of one component.
Recommended Response Action
One or more expander modules have experienced an error or been removed from the peripheral sled. Determine which expander have experienced an error or been removed and replace it.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1227

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The peripheral sled in slot arg1 redundancy has been restored.
Arguments
  • arg1 = slot number
Detailed Description
The data path redundancy to the peripheral sled identified in the message has been restored.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1228

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The iDRAC on the sled arg1 is not communicating with the Management Module(MM).
Arguments
  • arg1 = slot Number
Detailed Description
The iDRAC on the sled identified in the message is not communicating with the Management Module (MM).
Recommended Response Action
1) Update the firmware versions of iDRAC and Management Module (MM) to ensure that both have latest applicable versions. 2) If the issue persists, reset iDRAC in the sled. To reset iDRAC using the OpenManage Enterprise-Modular Graphical User Interface (GUI) a) Log in to the GUI. b) Select Hardware. c) Select Chassis Slots. d) Select the slot where the sled is inserted and select iDRAC Reset. 3) If the issue persists and the sled can be safely powered off, select System Reseat in step (d). To reseat by running a RACADM command at the Command Line Interface (CLI), run racadm serveraction -m server- -f reseat. 4) If the issue persists and the sled can be safely powered off, remove the sled, wait for one minute, and then reinsert the sled. 5) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC1229

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage mappings for server in slot arg1 have been accepted.
Arguments
  • arg1 = server slot
Detailed Description
The replaced sled in the specified slot was allowed to keep the same storage mapping information as the previous sled.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1230

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage mappings for server in slot arg1 have been cleared.
Arguments
  • arg1 = server slot
Detailed Description
The replaced sled in the specified slot was not allowed to keep the same storage mapping information as the previous sled.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1231

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Flash corruption occurred in both the partitions of the component arg1.
Arguments
  • arg1 = Component Name
Detailed Description
A Flash corruption occurred in both the partitions of the component identified in the message.
Recommended Response Action
Replace the Management Module by contacting your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1232

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The virtual reseat operation is initiated on the sled slot arg1 which is unoccupied or not the primary slot of a sled that occupies multiple slots.
Arguments
  • arg1 = n
Detailed Description
The virtual reseat operation is initiated on the sled slot identified in the message on either an empty or inactive slot of a multi-slot sled.
Recommended Response Action
Do the following: 1) Ensure that a sled is installed in the slot. 2) If a sled occupying multiple slots is installed, perform the virtual reseat operation on the adjacent slot.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1233

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to virtually reseat the sled arg1 because the Chassis is in OFF state.
Arguments
  • arg1 = n
Detailed Description
The sled identified in the message cannot be virtually reseated because the Chassis is in OFF state.
Recommended Response Action
Power on the Chassis by doing the following and retry the operation: 1) By using the OpenManage Enterprise-Modular GUI, click Power Control and select Power On. 2) By using the RACADM Command Line Interface (CLI), run the command: racadm chassisaction -m chassis powerup. For more information about powering on the system, see the OpenManage Enterprise-Modular Users Guide, RESTful API Guide, or RACADM CLI Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC1234

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the iDRAC Power Reset operation on the sled arg1 because the sled is not managed by an iDRAC.
Arguments
  • arg1 = sled Name
Detailed Description
The iDRAC Power Reset operation cannot be completed on the sled identified in the message because the sled is not managed by an iDRAC.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 cable or interconnect is connected.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 cable or interconnect is not connected or is improperly connected.
Arguments
  • arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <name> cable or interconnect failure. Check connection
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage arg1 cable or interconnect is connected.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The storage arg1 cable is not connected, or is improperly connected.
Arguments
  • arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
Storage <name> cable or interconnect failure. Check connection
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 cable or interconnect is connected.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system board arg1 cable or interconnect is not connected, or is improperly connected.
Arguments
  • arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
System board <name> cable or interconnect failure. Check connection
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is not installed correctly.
Arguments
  • arg1 = name
Detailed Description
The device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
<name> is not installed correctly. Check connection
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is installed correctly.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch detected for mezzanine card arg1.
Arguments
  • arg1 = number
Detailed Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric type is then set for the CMC/MM and the CMC/MM will ensure that all subsequent IOMs and mezzanine cards match.
Recommended Response Action
Check chassis fabric type in CMC/MM GUI and compare to the type of IOM or mezzanine card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Mezzanine card arg1 is installed correctly.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The riser board cable or interconnect is connected.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The riser board cable or interconnect is not connected, or is improperly connected.
Detailed Description
The riser blade cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
Riser board cable or interconnect failure. Check connection
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC2012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch detected on fabric arg1 with server in slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
The fabric type on the server does not match that of the IO module.
Recommended Response Action
Check chassis fabric type in CMC/MM GUI and compare to the type of IOM or mezzanine card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fabric mismatch corrected on fabric arg1 with server in slot arg2.
Arguments
  • arg1 = name
  • arg2 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware misconfiguration detected on arg1.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
Make sure the hardware is installed correctly. Refer to the product documentation for correct configuration and installation procedures.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
A hardware misconfiguration detected on <name>. Check hardware
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is configured correctly.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC2016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch is detected between the server in slot arg1 and IO Module in slot arg2.
Arguments
  • arg1 = slot number
  • arg2 = slot number
Detailed Description
A fabric type mismatch is detected between the server in slot and I/O module as identified in the message.
Recommended Response Action
Check the chassis fabric type by using the Manage Module graphic user interface (GUI) and compare against the type of fabric used in the I/O or mezzanine card. To check chassis type on the Manage Module home page, select the server, and then view the I/O module properties. For more information about the compatible fabric types, see the Manage Module Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC2017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Fabric mismatch corrected between the server in slot arg1 and IO Module in slot arg2.
Arguments
  • arg1 = slot number
  • arg2 = slot number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch is detected between the server in slot arg1 and IO Module in slot arg2.
Arguments
  • arg1 = slot number
  • arg2 = slot number
Detailed Description
A fabric type mismatch is detected between the server in slot and I/O module as identified in the message.
Recommended Response Action
Check the chassis fabric type by using the Manage Module graphic user interface (GUI) and compare against the type of fabric used in the I/O or mezzanine card. To check chassis type on the Manage Module home page, select the server, and then view the I/O module properties. For more information about the compatible fabric types, see the Manage Module Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch is detected between the server in slot arg1 and IO Module in slot arg2.
Arguments
  • arg1 = slot number
  • arg2 = slot number
Detailed Description
A fabric type mismatch is detected between the server in slot and I/O module as identified in the message.
Recommended Response Action
Check the chassis fabric type by using the Manage Module graphic user interface (GUI) and compare against the type of fabric used in the I/O or mezzanine card. To check chassis type on the Manage Module home page, select the server, and then view the I/O module properties. For more information about the compatible fabric types, see the Manage Module Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2130

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The internal communication between the Manage Module and the arg1 control panel is restored.
Arguments
  • arg1 = left or right
Detailed Description
The internal communication between the Manage Module and the control panel identified in the message is restored, and the control panel is normally functioning.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2131

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Management Module cannot communicate with the arg1 control panel because of internal issues.
Arguments
  • arg1 = left or right
Detailed Description
The Management Module cannot communicate with the control panel identified in the message because of internal issues.
Recommended Response Action
Disconnect the input power supplied to the chassis and reconnect. If the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2132

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Coin Cell battery in the front panel is not working.
Detailed Description
The Coin Cell battery in the front panel is not working.
Recommended Response Action
Replace the Coin Cell battery. For more information about replacing, see the Management Module Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2133

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Coin Cell battery in the front panel is properly installed.
Detailed Description
The Coin Cell battery in the front panel was detected low and a new battery is installed.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2134

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 control panel is not installed, or the cable is not connected to the Manage Module.
Arguments
  • arg1 = left or right
Detailed Description
The control panel identified in the message is not installed, or the cable is not connected to the Manage Module.
Recommended Response Action
Turn off the chassis and check if the control panel identified in the message is properly installed.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2135

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to write the service tag to the sled in slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
Unable to write the service tag to the sled in slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC2136

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to write the asset tag to the sled in slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
Unable to write the asset tag to the sled in slot identified in the message.
Recommended Response Action
Retry the operation. If the issue persists contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC3000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is removed.
Arguments
  • arg1 = name
Detailed Description
The removed device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 is inserted.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 is removed.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
If removal was unintended, check presence, then re-insert.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 was inserted.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
IO module arg1 is removed.
Arguments
  • arg1 = number
Detailed Description
IO Module identified in the message is removed.
Recommended Response Action
If removal was unintended, check presence, then re-insert.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
IO module arg1 was inserted.
Arguments
  • arg1 = number
Detailed Description
IO Module identified in the message is inserted.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC3006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to QuickDeploy server in slot arg1.
Arguments
  • arg1 = number
Detailed Description
There are not enough IPv4 addresses reserved for the servers in this chassis. Therefore the newly inserted server could not be configured with the QuickDeploy feature.
Recommended Response Action
Do the following: 1) Check the number of reserved IPv4 addresses for QuickDeploy. 2) Modify it such that the newly inserted blade will obtain an IP address for QuickDeploy. 3) Reseat the server to retry the QuickDeploy operation or manually configure the network parameters for the server. (Note that some chassis models may require a response at the LCD panel).
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility detected between BMC/iDRAC firmware and CPU.
Detailed Description
A hardware incompatibility was detected between BMC/iDRAC firmware and Processor(s). An iDRAC or BMC firmware update is needed.
Recommended Response Action
Update the BMC/iDRAC firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
Incompatibility between BMC/iDRAC firmware and CPU. Update firmware
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility was corrected between BMC/iDRAC firmware and CPU.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility detected between BMC/iDRAC firmware and other hardware.
Detailed Description
A hardware incompatibility was detected between BMC/iDRAC firmware and other hardware. An iDRAC or BMC firmware update is needed.
Recommended Response Action
Update the BMC/iDRAC firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility was corrected between BMC/iDRAC firmware and other hardware.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware successfully updated for mezzanine card arg1.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware unsuccessfully updated for mezzanine card arg1.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
Check presence, re-install or reconnect, then re-attempt the update. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware successfully updated for embedded NIC.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC4013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware unsuccessfully updated for embedded NIC.
Detailed Description
No detailed description available.
Recommended Response Action
Check presence, re-install or reconnect, then re-attempt the update. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC4014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Link Tuning data successfully updated.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC4015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Link Tuning error detected.
Detailed Description
CMC/MM has old firmware and does not recognize the new device which has requested link tuning information. After updating the firmware the CMC/MM will recognize the device.
Recommended Response Action
Update the CMC/MM firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC4016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware incompatibility detected with mezzanine card arg1.
Arguments
  • arg1 = number
Detailed Description
The system has detected a mezzanine card that is not supported on this system.
Recommended Response Action
1) Review system documentation for supported mezzanine cards. 2) Replace mezzanine card with a supported mezzanine card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility is detected between arg1arg2 and arg3arg4.
Arguments
  • arg1 = name1
  • arg2 = location1
  • arg3 = name2
  • arg4 = location2
Detailed Description
The system has detected an unsupported hardware component. A hardware incompatibility is detected between the components identified in the message.
Recommended Response Action
Do the following: 1) Review system documentation for the hardware components identified in the message. 2) Replace unsupported components with supported components.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4018

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware incompatibility was corrected between arg1arg2 and arg3arg4.
Arguments
  • arg1 = name1
  • arg2 = location1
  • arg3 = name2
  • arg4 = location2
Detailed Description
A hardware incompatibility was corrected between the components identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4019

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to control the fan speed because a sled mismatch or hardware incompatibility is detected.
Detailed Description
The fan speed cannot be controlled because a sled mismatch or hardware incompatibility is detected. This results in fans rotating at the maximum allowed speed (RPM).
Recommended Response Action
Remove the sled in which a hardware incompatibility is detected and replace with a compatible working sled. For more information about hardware compatibility, see the platform Owners Manual available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
Unable to control the fan speed because a sled mismatch or hardware incompatibility is detected.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC4020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Airflow in sled arg1 is not compatible with the flow of air in chassis.
Arguments
  • arg1 = number
Detailed Description
Airflow in the sled identified in the message is not compatible with the flow of air in chassis. This may result in the sled not getting powered on.
Recommended Response Action
Airflow in the sled identified in the message is not compatible with the flow of air in chassis. This may result in the sled not getting powered on.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is online.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is offline.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If unexpected, check presence, then re-install or reconnect.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch detected on arg1.
Arguments
  • arg1 = name
Detailed Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric type is then set for the CMC/MM and the CMC/MM will ensure that all subsequent IOMs and mezzanine cards match.
Recommended Response Action
Check chassis fabric type in CMC/MM GUI and compare to the type of IOM or mezzanine card.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is operating correctly.
Arguments
  • arg1 = name
Detailed Description
The device is operating normally.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A link tuning failure detected on arg1.
Arguments
  • arg1 = name
Detailed Description
CMC/MM has old firmware and does not recognize the new device which has requested link tuning information. After updating the firmware the CMC/MM will recognize the device.
Recommended Response Action
Update the CMC/MM firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A failure is detected on arg1.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Console is not available for the arg1.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1has reported a power related issue.arg2.
Arguments
  • arg1 = name
  • arg2 = fault string
Detailed Description
A power fault was indicated on the device indicated in the message.
Recommended Response Action
Power off the system and reseat the specified hardware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 cannot detect any hosts.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is powered off based on a user request.
Arguments
  • arg1 = name
Detailed Description
The device is powered off based on a request from the user. The device is not functional. Ensure that this action was intentional. The system performance is downgraded.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
On screen display (OSCAR) is not functional for the arg1.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 is not functional and is powered off.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC5030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
IO module arg1 is online.
Arguments
  • arg1 = number
Detailed Description
IO Module identified in the message is online.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
IO module arg1 is offline.
Arguments
  • arg1 = number
Detailed Description
The CMC/MM has powered off the IOM identified in the message.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A fabric mismatch detected on IO module arg1.
Arguments
  • arg1 = number
Detailed Description
The fabric type for IOMs on the same chassis fabric must match.
Recommended Response Action
Check chassis fabric type in CMC/MM GUI and compare to the type of both IOMs.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
IO module arg1 is operating correctly.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A link tuning failure detected on IO module arg1.
Arguments
  • arg1 = number
Detailed Description
Link tuning table not supported for this IO modular.
Recommended Response Action
Update the CMC/MM firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An over-temperature event detected on I/O module arg1.
Arguments
  • arg1 = number
Detailed Description
The I/O module over heated.
Recommended Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check the temperature sensor status for the chassis and make sure it is within the chassis operating temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A failure is detected on IO module arg1.
Arguments
  • arg1 = number
Detailed Description
The IOM module performance may be impact.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
I/O module arg1 failed to boot.
Arguments
  • arg1 = number
Detailed Description
The firmware on the I/O module did not boot. The problem may be because the I/O module is not inserted correctly.
Recommended Response Action
Reseat I/O module. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC5038

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The CMC/MM is unable to turn on the I/O module arg1.
Arguments
  • arg1 = number
Detailed Description
The I/O module identified in the message cannot be turned on by the CMC/MM.
Recommended Response Action
Do one of the following: 1) Perform a Powercycle operation on the I/O module identified in the message. A Powercycle operation can be performed using the RACADM command line utility by typing "racadm chassisaction -m switch-N powercycle (where N is the switch number)". 2) Reseat the I/O module identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 controller is offline.
Arguments
  • arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 controller is online.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 controller is stuck in boot mode.
Arguments
  • arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power.If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 controller is booting.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Cannot communicate with arg1 controller.
Arguments
  • arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC6005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Communications restored for arg1 controller.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a normal state.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a warning state from a normal state.
Arguments
  • arg1 = number
Detailed Description
Server health changed to a warning state from a normal state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a critical state from either a normal or warning state.
Arguments
  • arg1 = number
Detailed Description
Server health changed to a critical state from either a normal or warning state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a non-recoverable state from a less severe state.
Arguments
  • arg1 = number
Detailed Description
Server <number> health changed to a non-recoverable state from a less severe state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a warning state from more severe state.
Arguments
  • arg1 = number
Detailed Description
Server <number> health changed to a warning state from more severe state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a critical state from a non-recoverable state.
Arguments
  • arg1 = number
Detailed Description
Server <number> health changed to a critical state from a non-recoverable state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Server arg1 health changed to a non-recoverable state.
Arguments
  • arg1 = number
Detailed Description
Server <number> health changed to a non-recoverable state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

HWC7014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An invalid cable or incorrect cable configuration is detected.
Detailed Description
An invalid cable related hardware configuration detected on the system.
Recommended Response Action
Make sure the hardware and related cables are installed correctly. For information about configuration and installation procedures, see the systems Owners Manual available at the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 is ready for data requests.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module identified in the message is now ready for data requests.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 is not supported.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module identified in the message is not supported.
Recommended Response Action
Make sure that the IO Module inserted has correct configuration.
Category
Configuration (HWC = Hardware Config)
Severity
Critical
Trap/EventID
10521
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A virtual reseat operation is initiated for the IOM in the IOM slot arg1.
Arguments
  • arg1 = slot number
Detailed Description
A virtual reseat operation is initiated for the IOM in the IOM slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7504

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The data object arg1 has been changed in the IO Module in slot arg2.
Arguments
  • arg1 = object name
  • arg2 = slot name
Detailed Description
The IO Module identified in the message has a change in the data object identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7506

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 is not responding to data requests due to communication error.
Arguments
  • arg1 = slot number
Detailed Description
The IO Module identified in the message is unable to respond to data requests due to a communication error.
Recommended Response Action
Do the following and retry the operation. 1) Wait until the communication is restored and retry the operation. 2) Reset the I/O module. If the issues persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7507

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The alert on the I/O Module in slot arg1 is cleared because the communication is restored for processing data requests.
Arguments
  • arg1 = slot number
Detailed Description
The alert on the I/O module in slot identified in the message is cleared because the communication is restored for processing data requests.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7508

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to perform controller firmware update on IO Module in slot arg1.
Arguments
  • arg1 = slot name
Detailed Description
Unable to perform controller firmware update on IO Module identified in the message.
Recommended Response Action
Reseat the IO Module and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7509

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A failsafe event has occurred in the IO Module in slot arg1.
Arguments
  • arg1 = slot name
Detailed Description
A failsafe event has occurred in the IO Module identified in the message.
Recommended Response Action
Physically reseat the IO Module and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7510

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 has exceeded temperature threshold.
Arguments
  • arg1 = slot number
Detailed Description
The IO Module identified in the message has exceeded temperature threshold.
Recommended Response Action
1) Make sure fans are installed and working correctly. 2) Check the temperature sensor status for the chassis and make sure it is within the chassis operating temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7511

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power fault event has occurred in the IO Module in slot arg1.
Arguments
  • arg1 = slot name
Detailed Description
Power fault event has occurred in the IO Module identified in the message.
Recommended Response Action
Reseat the IO Module and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7512

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System fault event has occurred in the IO Module in slot arg1.
Arguments
  • arg1 = slot name
Detailed Description
System fault event has occurred in the IO Module identified in the message.
Recommended Response Action
Reseat the IO Module and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC7513

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to boot the IO module in the slot arg1 within the expected time and the IO module is currently power cycled.
Arguments
  • arg1 = slot number
Detailed Description
The IO module in the slot identified in the message cannot be booted within the expected time and the IO module is currently power cycled.
Recommended Response Action
No response action is required. The IO module is automatically being power cycled.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7514

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 is not configured.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module in the slot specified has no configuration information.
Recommended Response Action
Configure the IO module and retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7515

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 requires a power cycle.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module in the slot specified has a firmware update or configuration change that requires a power cycle to take effect.
Recommended Response Action
Power cycle the IO module and retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7516

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The configuration information of the IO Module in slot arg1 does not match the current chassis.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module in the slot specifieds configuration data is from a different chassis. No storage mapping will be performed.
Recommended Response Action
Put the IO Module back in the original chassis or clear the IO Modules configuration.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7517

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The configuration information of the IO Module in slot arg1 does not match its peer IOM Module configuration information.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module in the slot specifieds configuration data and that of its peer is inconsistent. This inconsistency cannot be automatically resolved.
Recommended Response Action
Clear both IO Modules configuration and reconfigure them.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7518

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 cannot communicate with its peer IO Module.
Arguments
  • arg1 = slot name
Detailed Description
The IO Module in the slot identified in the message cannot communicate with its peer IO Module. This can result in inconsistencies on the fabric.
Recommended Response Action
Reseat the peer IO Module, if the problem persists check for newer device firmware, if the problem still persists contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7519

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO module in slot arg1 has an issue with its software application. Error code: arg2.
Arguments
  • arg1 = slot name
  • arg2 = vendor error code
Detailed Description
The IO module in slot identified in the message has an issue with its software application.
Recommended Response Action
Reseat the peer IO module. If the issue persists, check if a latest device firmware is available and update the version. If the issue still persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7520

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 has encountered a critical issue with its application software. Error Code: arg2.
Arguments
  • arg1 = slot name
  • arg2 = vendor error code
Detailed Description
The IO module in slot identified in the message has a critical issue with its application software.
Recommended Response Action
Reseat the peer IO module. If the issue persists, check if a latest device firmware is available and update the version. If the issue still persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7521

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 fault event has been cleared for IO Module in slot arg2.
Arguments
  • arg1 = Fault Type
  • arg2 = slot number
Detailed Description
The fault identified in the message has been cleared for the IO Module identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7522

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to fully complete the update operation of the Controller firmware because the IO Module in slot arg1 is turned on.
Arguments
  • arg1 = slot Number
Detailed Description
The update operation of the Controller firmware version cannot be fully completed because the IO Module in slot identified in the message is powered on. IO Module must be virtually reseated to make the update operation fully effective.
Recommended Response Action
Perform a Virtual Reseat operation on the IO module to complete the controller firmware update. To reseat by using the Management Modules Graphical User Interface (GUI), on the IO Modules page, click Power Actions > System Reseat.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7523

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in slot arg1 did not boot within the expected time.
Arguments
  • arg1 = slot name
Detailed Description
The IO module identified in the message may have taken more time to boot than was expected or the IO module did not boot.
Recommended Response Action
Reinsert the I/O Module or perform a virtual reseat and retry the operation. To perform a Virtual Reseat operation on the IO module by using the Management Modules Graphical User Interface (GUI), on the IO Modules page, click Power Control then System Reseat. If the problem persists, contact technical support.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7524

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health state of IO module in the slot arg1 is good.
Arguments
  • arg1 = slot Name
Detailed Description
The health state of IO module in the slot identified in the message is good.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7525

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of IO module in the slot arg1 is in Warning state.
Arguments
  • arg1 = slot Name
Detailed Description
The health of IO module in the slot identified in the message is in Warning state.
Recommended Response Action
1) Enter OpenManage Enterprise - Modular in the Chassis Subsystem section, click the View Details link corresponding to the IOM slot name in the SUBSYSTEM column. 2) In the dialog box, read through the message(s) and act accordingly. For more information, see the Dell OpenManage Enterprise Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7526

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of IO module in the slot arg1 is in Critical state.
Arguments
  • arg1 = slot Name
Detailed Description
The health of IO module in the slot identified in the message is in Critical state.
Recommended Response Action
1) On the OpenManage Enterprise Modular Graphics User Interface (GUI), in the Chassis Subsystem section, click the View Details link corresponding to the IOM slot name in the SUBSYSTEM column. 2) In the dialog box, read through the message(s) and act accordingly. For more information, see the Dell OpenManage Enterprise Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7527

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the requested operation because: arg1.
Arguments
  • arg1 = reason for issue
Detailed Description
The requested operation cannot be completed because of the reason specified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7528

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the requested operation because: arg1.
Arguments
  • arg1 = reason for issue
Detailed Description
The requested operation cannot be completed because of the reason identified in the message.
Recommended Response Action
Enter valid and supported values and retry the operation. If the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7529

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the requested operation because: arg1.
Arguments
  • arg1 = reason for issue
Detailed Description
The requested operation cannot be completed because of the reason identified in the message.
Recommended Response Action
Retry the operation when the device is in service. If the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7530

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to process the I/O Module request because of an internal system error.
Detailed Description
The I/O Module request cannot be processed because of an internal system error.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7531

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The I/O Module in slot arg1 cannot process the request because an invalid parameter is entered.
Arguments
  • arg1 = slot name
Detailed Description
The request cannot be processed by the I/O module in the slot identified in the message because of an internal system error.
Recommended Response Action
Enter a valid parameter and retry the operation. If the issue persists, contact your service provider. For information about valid parameters, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7532

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request cannot be processed by the I/O Module in slot arg1 because the necessary service is not running.
Arguments
  • arg1 = slot name
Detailed Description
The request cannot be processed by the I/O Module in the slot identified in the message because the necessary service is not running.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider. For more information, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7533

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The request cannot be processed by the I/O Module in slot arg1 because the I/O Module is busy in processing other requests.
Arguments
  • arg1 = slot name
Detailed Description
The request cannot be processed by the I/O Module in slot identified in the message because the I/O Module is busy in processing other requests.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider. For more information, see the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7534

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The IO Module in the slot arg1 is unresponsive.
Arguments
  • arg1 = slot name
Detailed Description
The IO module identified in the message is unresponsive and fails to boot successfully.
Recommended Response Action
Reseat the IO module. If the issue persists, try the firmware update procedure for the IO module. If the issue persists further, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7535

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System fault event has occurred in the IO Module in slot arg1.
Arguments
  • arg1 = slot name
Detailed Description
System fault event has occurred in the IO Module identified in the message.
Recommended Response Action
Reference IO Module vendor documentation for information on IO Module system fault events.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7536

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System critical event has occurred in the IO Module in slot arg1. The following fault message was logged by the IOM: arg2.
Arguments
  • arg1 = slot name
  • arg2 = fault message
Detailed Description
System critical event has occurred in the IO Module identified in the message.
Recommended Response Action
See detailed description for recommended action.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC7537

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System warning event has occurred in the IO Module in slot arg1. The following fault message was logged by the IOM: arg2.
Arguments
  • arg1 = slot name
  • arg2 = fault message
Detailed Description
System warning event has occurred in the IO Module identified in the message.
Recommended Response Action
See detailed description for recommended action.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unknown device plug event occurred at this location: arg1. Additional Details: arg2.
Arguments
  • arg1 = device location
  • arg2 = details
Detailed Description
An unknown device plug event occurred at the identified device location. Along with the device location, additional event details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
OMSA Event ID
5650
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A device was added to the system at this location: arg1. Additional Details: arg2.
Arguments
  • arg1 = device location
  • arg2 = details
Detailed Description
A device was added to the system at the location identified in the message. Along with the device location, additional event details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
OMSA Event ID
5651
OMSA Trap ID
5651
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The device was removed from the system at this location: arg1. Additional Details: arg2.
Arguments
  • arg1 = device location
  • arg2 = details
Detailed Description
A device was removed from the system at the location identified in the message. Along with the device location, additional event details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
OMSA Event ID
5652
OMSA Trap ID
5652
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A configuration error was detected in the device located here: arg1. Additional Details: arg2.
Arguments
  • arg1 = device location
  • arg2 = details
Detailed Description
A configuration error was detected for a pluggable device installed at the location identified in the message. The device may not be installed correctly.
Recommended Response Action
Reinsert the device or try inserting a different device of the same type and retry the operation. If the issue persists, check the system documentation to make sure the device is supported or contact your service provider.
Category
Audit (HWC = Hardware Config)
Severity
Critical
OMSA Event ID
5653
OMSA Trap ID
5653
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The SD card device sensor has failed. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
The SD card device sensor of the type identified in the message has failed. The current status of the SD card is also displayed.
Recommended Response Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue persists, do one of the following to resolve the error: 1) If the SD card sensor is installed on the internal SD module, replace the module. 2) If the SD card sensor is embedded on the system board, replace the system board. . For more information, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Critical
OMSA Event ID
5750
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The SD card device has returned to normal state. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
The SD card device has returned to a normal state. The SD card type and the current status of the SD card is also displayed.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
OMSA Event ID
5752
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The SD card device state has changed to a warning state. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
The SD card device is not functioning correctly, and its state has changed to a warning state.
Recommended Response Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue persists, do one of the following to resolve the error: 1) If the SD card sensor is installed on the internal SD module, replace the module. 2) If the SD card sensor is embedded on the system board, replace the system board. . For more information, contact your service provider.
Category
System Health (HWC = Hardware Config)
Severity
Warning
OMSA Event ID
5753
OMSA Trap ID
5753
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The SD card has failed. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
The SD card sensor detected an SD card failure.
Recommended Response Action
Replace the old SD card with a new SD card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
OMSA Event ID
5754
OMSA Trap ID
5754
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The SD card has failed. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
An SD card device sensor has detected an irrecoverable error in the SD card.
Recommended Response Action
Replace the old SD card with a new SD card.
Category
System Health (HWC = Hardware Config)
Severity
Critical
OMSA Event ID
5755
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
SD card device sensor value unknown. SD card location: arg1, SD card device type: arg2, SD card state: arg3.
Arguments
  • arg1 = location
  • arg2 = type
  • arg3 = state
Detailed Description
An SD card device sensor in the identified system could not obtain a reading.
Recommended Response Action
Remove and reinsert the identified SD card.
Category
System Health (HWC = Hardware Config)
Severity
Informational
OMSA Event ID
5751
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The System Configuration Check operation resulted in the following issue: arg1.
Arguments
  • arg1 = msg
Detailed Description
The issue identified in the message is observed in the System Configuration Check operation.
Recommended Response Action
Do the following and retry the operation: 1) Disconnect the input power. 2) Check for proper cable connection and component placement. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
<msg>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The System Configuration Check operation resulted in multiple arg1 issues.
Arguments
  • arg1 = msg
Detailed Description
Multiple issues are observed in the System Configuration Check operation.
Recommended Response Action
Do the following and retry the operation: 1) Disconnect the input power. 2) Check for proper cable connection and component placement. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
LCD Message
Multiple <msg> config errors detected.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Multiple configuration related issues on the device arg1 are resolved.
Arguments
  • arg1 = msg
Detailed Description
Multiple configuration related issues on the device identified in the message are resolved.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A configuration related issue on the device arg1 is resolved.
Arguments
  • arg1 = msg
Detailed Description
A configuration related issue on the device identified in the message is resolved.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of the SDPM is affected by a critical cable issue.
Detailed Description
The health of the SDPM is affected by a critical cable issue. Subsequent persistent memory save operations will fail.
Recommended Response Action
Refer to the platform documentation for details related to SDPM subsystem. Copy any data in the persistent memory to another persistent device such as a hard drive. Power off the system and remove input power. Inspect and re-insert all the SDPM power and data cables.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The health of the SDPM is affected by a critical cable issue.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

HWC8020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A thermally unsupported arg1 configuration is detected.
Arguments
  • arg1 = component
Detailed Description
A thermally unsupported configuration is detected in the component identified in the message. Fan speeds may increase to protect the system.
Recommended Response Action
Do the following and retry the operation: 1) Review the ID HWC8022 message in the Lifecycle Log for more information about the unsupported configuration. 2) Resolve the unsupported configuration or revert to any recent system configuration changes. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
A thermally unsupported <component> configuration is detected.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD
Applicable Event or Alert Types
CMC—Not Applicable

HWC8021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A thermally unsupported arg1 configuration is resolved.
Arguments
  • arg1 = component
Detailed Description
A thermally unsupported configuration issue is resolved in the component identified in the message. Fan speeds may return to normal.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A thermally unsupported arg1 configuration is detected: arg2.
Arguments
  • arg1 = component
  • arg2 = description
Detailed Description
A thermally unsupported configuration is detected in the component because of the reason identified in the message.
Recommended Response Action
Do the following and retry the operation: 1) Resolve the unsupported configuration or revert to any recent system configuration changes. 2) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the arg1 must be installed.
Arguments
  • arg1 = deviceName
Detailed Description
The validated Configuration Check result indicates that the device indicated in the message must be installed for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Install the device indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <deviceName> must be installed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the arg1 must be removed.
Arguments
  • arg1 = deviceName
Detailed Description
The validated Configuration Check result indicates that the device indicated in the message must be removed for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Remove the device indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <deviceName> must be removed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the arg1 is of incorrect type. Replace it with the type arg2.
Arguments
  • arg1 = deviceName
  • arg2 = msg
Detailed Description
The validated Configuration Check result indicates that the device indicated in the message is of incorrect type. Replace it with the device type indicated in the message for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Install the device with the type indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <deviceName> is of incorrect type. Replace it with the type <msg>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the cable connecting arg1 and arg2 must be removed.
Arguments
  • arg1 = location1
  • arg2 = location2
Detailed Description
The validated Configuration Check result indicates that the cable indicated in the message must be removed for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Remove the cable indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The cable connecting <location1> and <location2> must be removed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the cable connecting arg1 and arg2 must be installed.
Arguments
  • arg1 = location1
  • arg2 = location2
Detailed Description
The validated Configuration Check result indicates that the cable indicated in the message must be installed for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Install the cable indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The cable connecting <location1> and <location2> must be installed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check is unable to communicate with arg1.
Arguments
  • arg1 = deviceName
Detailed Description
The validated Configuration Check result indicates that the Configuration Check is unable to communicate with the device indicated in the message.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Reinstall the device and retry the operation. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The validated Configuration Check is unable to communicate with <deviceName>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the arg1 must be installed in arg2.
Arguments
  • arg1 = deviceName
  • arg2 = location
Detailed Description
The validated Configuration Check result indicates that the device indicated in the message must be installed in the location for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Install the device in the location indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <deviceName> must be installed in <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The validated Configuration Check result indicates that the arg1 in arg2 must be removed.
Arguments
  • arg1 = deviceName
  • arg2 = location
Detailed Description
The validated Configuration Check result indicates that the device in the location indicated in the message must be removed for proper functioning of the server.
Recommended Response Action
Do the following: 1) Disconnect the input power. 2) Remove the device in the location indicated in the message. 3) If the issue persists, retry the operation.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
The <deviceName> in <location> must be removed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC8501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the operation because of an issue with the I/O panel cable.
Detailed Description
The operation could not successfully completed because of an issue with the I/O panel cable.
Recommended Response Action
Do one of the following and retry the operation: 1) Connect the I/O panel cable properly 2) Replace the I/O panel cable.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The I/O panel cable is connected.
Detailed Description
The internal cable that connects the I/O panel to the system board is properly connected.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The internal communication between the Chassis Management Controller (CMC) and the arg1 control panel is restored.
Arguments
  • arg1 = left or right
Detailed Description
The internal communication between the Chassis Management Controller (CMC) and the control panel identified in the message is restored, and the control panel is normally functioning.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8504

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Chassis Management Controller/Management Module (CMC/MM) cannot communicate with the arg1 control panel because of internal issues.
Arguments
  • arg1 = left or right
Detailed Description
The Chassis Management Controller/Management Module (CMC/MM) cannot communicate with the control panel identified in the message because of internal issues.
Recommended Response Action
Disconnect the input power supplied to the chassis and reconnect. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8506

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to synchronize control panel firmware due to internal error.
Detailed Description
During a Chassis Management Controller (CMC) firmware update, the control panel firmware synchronization failed. The control panel may be inoperable.
Recommended Response Action
Remove and reapply chassis input power. If problem persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8507

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The USB device inserted in to the I/O Panel USB port is causing an issue and cannot be used.
Detailed Description
The USB device inserted in to the I/O Panel USB port is causing an issue and cannot be used. The USB device may not be operational.
Recommended Response Action
Remove the USB device from the I/O Panel USB port, and then retry the operation with another USB device.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8508

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A device causing an issue in the I/O panel USB port is removed.
Detailed Description
A device causing an issue in the I/O panel USB port is removed.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8509

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One or more PCIe switch heatsinks are not properly attached.
Detailed Description
The heatsinks are critical for providing cooling to the PCIe switches. If a PCIe switch stops functioning due to improper cooling, the PCIe subsystem may no longer function correctly and data loss may occur.
Recommended Response Action
Immediately turn off the Chassis by pressing the Chassis power button or removing chassis input power. The Chassis can be turned off remotely by running the following RACADM command "racadm chassisaction -m chassis nongraceshutdown". After turning off, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8510

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The heat sinks of the PCIe switches are properly attached.
Detailed Description
The heat sinks of the PCIe switches are properly attached.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*

HWC8601

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read data from the chassis permanent storage.
Detailed Description
Unable to read data from the Field Replaceable Unit (FRU) or the chassis user configuration.
Recommended Response Action
In a single chassis controller configuration, reboot the chassis controller. In a redundant chassis controller configuration, if failover is not occurring automatically, issue a force failover command.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8602

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The ability to read data from the chassis permanent storage is restored.
Detailed Description
The ability to read data from the Field Replaceable Unit (FRU) or the chassis user configuration is restored.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8603

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to write data to the chassis permanent storage.
Detailed Description
Unable to write data to the Field Replaceable Unit (FRU) or the chassis user configuration.
Recommended Response Action
Back up the system data immediately. In a single chassis controller configuration, reboot the chassis controller. In a redundant chassis controller configuration if failover is not occurring automatically, issue a force failover command.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8604

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The ability to write data to the chassis permanent storage is restored.
Detailed Description
The ability to write data to the Field Replaceable Unit (FRU) or the chassis user configuration is restored.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8605

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The KVM display monitor is successfully inserted into the chassis.
Detailed Description
The KVM display monitor is successfully inserted into the chassis.
Recommended Response Action
No response action is required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8606

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The KVM display monitor is removed from the chassis.
Detailed Description
The KVM display monitor is removed from the chassis.
Recommended Response Action
No response action is required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

HWC8607

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The data communication with the device arg1 running on the port arg2 is lost.
Arguments
  • arg1 = Device FQDD
  • arg2 = Port Number
Detailed Description
The data communication with the device identified in the message is lost.
Recommended Response Action
Run the following RACADM command at the Command Line Interface (CLI) and retry the operation: racadm racreset. For more information about RACADM commands of iDRAC, see the latest version of "iDRAC with Lifecycle Controller RACADM CLI Guide" available on the support site.
Category
Audit (HWC = Hardware Config)
Severity
Warning
Trap/EventID
8474
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC8608

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The lost data communication with the device arg1 running on the port arg2 is now restored.
Arguments
  • arg1 = Device FQDD
  • arg2 = Port Number
Detailed Description
The lost data communication with the device identified in the message is now restored.
Recommended Response Action
No response action required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
Trap/EventID
8475
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The status of device arg1 is restored to normal.
Arguments
  • arg1 = name
Detailed Description
The inlet temperature, fan health, and total power associated with the BOSS device identified in the message are restored to normal.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 device may not function as expected because the device health status turned to Warning.
Arguments
  • arg1 = name
Detailed Description
The BOSS device identified in the message may not function because either the inlet temperature, fan health, or total power associated with the BOSS device is reaching the threshold value.
Recommended Response Action
Make sure that the inlet temperature, fan health, or total power associated with the BOSS device is within specified limits. For information about specified values, see the iDRAC 9.0 and later Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 device may not function as expected because the device health status turned to Critical.
Arguments
  • arg1 = name
Detailed Description
The BOSS device identified in the message may not function because either the inlet temperature, fan health properties, or total power associated with the BOSS device has exceeded the threshold values.
Recommended Response Action
Make sure that the inlet temperature, fan health, or total power associated with the BOSS device are within specified limits. For information about specified values, see the iDRAC 9.0 and later Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The arg1 device may not function as expected because a Watchdog failure is detected.
Arguments
  • arg1 = name
Detailed Description
The BOSS device identified in the message may not function because of a Watchdog failure.
Recommended Response Action
Make sure that the inlet temperature, fan health, or total power associated with the BOSS device is within specified limits. For information about specified values, see the iDRAC 9.0 and later Users Guide available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The BOSS-S1 device does not have a fan installed in it.
Detailed Description
The BOSS device identified in the message does not have a fan installed in it.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The BOSS-S1 device has a fan installed in it.
Detailed Description
The BOSS device identified in the message has a fan installed in it.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The server board arg1 cable or the server interconnect is not available.
Arguments
  • arg1 = name
Detailed Description
The server board cable or the server interconnect may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Make sure that the server board cable and interconnect is available and properly connected. For more information about connecting, see the Installation and Service Manual of the respective server available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
LCD Message
System board <name> cable or interconnect is absent.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A communication error is observed either in the server board arg1 cable or the server interconnect.
Arguments
  • arg1 = name
Detailed Description
A communication error is observed either in the server board cable identified in the message or the server interconnect.
Recommended Response Action
Make sure that the server board cable and interconnect is available and properly connected. For more information about connecting, see the Installation and Service Manual of the respective server available on the support site.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
LCD Message
System board <name> cable or interconnect has communication error.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The network link connection status of arg1, port arg2, is unavailable (down).
Arguments
  • arg1 = Controller ID
  • arg2 = port ID
Detailed Description
The network link connection status of the network port identified in the message is unavailable (down).
Recommended Response Action
Make sure that the network cable is connected and the network device is functioning.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The network link connection status of arg1, port arg2, is available (up).
Arguments
  • arg1 = Controller ID
  • arg2 = port ID
Detailed Description
The network link connection status of the device identified in the message is available (up).
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

HWC9021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A message is logged by the arg1 operating system. Message: arg2.
Arguments
  • arg1 = DPU Friendly FQDD
  • arg2 = message
Detailed Description
A message is logged by the DPU operating system identified in the message.
Recommended Response Action
Do the following to resolve the issue: 1) Verify the DPU operating system log. 2) Restart the DPU. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A message is logged by the arg1 operating system. Message: arg2.
Arguments
  • arg1 = DPU Friendly FQDD
  • arg2 = message
Detailed Description
A message is logged by the DPU operating system identified in the message.
Recommended Response Action
Do the following to resolve the issue: 1) Verify the DPU operating system log. 2) Restart the DPU. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Trap/EventID
2330
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9023

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A message is logged by the arg1 operating system. Message: arg2.
Arguments
  • arg1 = DPU Friendly FQDD
  • arg2 = message
Detailed Description
A message is logged by the DPU operating system identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Trap/EventID
2331
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9050

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
iDRAC is unable to communicate to the Graphics Processing Unit (GPU) device arg1 because the device is not ready or not responding.
Arguments
  • arg1 = GPU FQDD
Detailed Description
iDRAC is unable to communicate to the Graphics Processing Unit (GPU) device identified in the message because the device is not ready or not responding to the system management bus (SMB) commands.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9051

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of Graphics Processing Unit (GPU) device arg1 is degraded because of single or double bit errors on the memory cells.
Arguments
  • arg1 = GPU FQDD
Detailed Description
The health of Graphics Processing Unit (GPU) device identified in the message is degraded. There are a few memory pages retired on the device because of a Double Bit Error (DBE) or two consecutive Single Bit Errors (SBEs) on the memory cell. The memory pages are retired to avoid any runtime corruption of data.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9052

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The health of Graphics Processing Unit (GPU) device arg1 is critical because of single or double bit errors on the memory cells.
Arguments
  • arg1 = GPU FQDD
Detailed Description
The health of Graphics Processing Unit (GPU) device identified in the message is degraded. There are a few memory pages retired on the device because of a Double Bit Error (DBE) or two consecutive Single Bit Errors (SBEs) on the memory cell. The memory pages are retired to avoid any runtime corruption of data.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9053

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The data communication with the device arg1 (arg2) is lost.
Arguments
  • arg1 = device friendly fqdd name
  • arg2 = device fqdd
Detailed Description
The data communication with the device identified in the message is lost.
Recommended Response Action
By using the iDRAC Graphical User Interface (GUI), reset iDRAC. Click Maintenance > Diagnostics > Reset iDRAC.
Category
Audit (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9054

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An issue where the data communication with the device arg1, (arg2), was lost, is now resolved.
Arguments
  • arg1 = device-friendly FQDD name
  • arg2 = device FQDD
Detailed Description
The data communication issue observed in the device identified in the message, is now resolved.
Recommended Response Action
No response action required.
Category
Audit (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9055

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The QuickAssist Technology (QAT) device has failed.
Detailed Description
A QuickAssist Technology (QAT) device has failed.
Recommended Response Action
Gather a SupportAssist collection (TSR) using iDRAC. Visit www.dell.com/support to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

HWC9056

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A mismatch of GPU models is detected on the server which might result in suboptimal performance.
Detailed Description
A mismatch of GPU models is detected on the server which might result in suboptimal performance.
Recommended Response Action
Ensure that all the GPUs installed on the server are of same model.
Category
Configuration (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9090

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware Platform Module hardware drift detected Old Hardware Platform Module ID: arg1, New Hardware Platform Module ID: arg2.
Arguments
  • arg1 = old uniqueid
  • arg2 = new uniqueid
Detailed Description
BMC has detected that the current Hardware Platform Module ID is different from the previous Hardware Platform Module ID. This could be due to a Hardware Platform Module replacement.
Recommended Response Action
If the Hardware Platform Module replacement is valid then no response action is required. If the Hardware Platform Module replacement is not valid then replace the new Hardware Platform Module with a valid one.
Category
Configuration (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9091

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Hardware Platform Module hardware drift detection could not be performed due to: arg1.
Arguments
  • arg1 = Reason
Detailed Description
BMC is unable to detect Hardware Platform Module drift due to the reason indicated in the message.
Recommended Response Action
Do the following: 1) Upgrade the device firmware to the latest version. 2) Restart iDRAC. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Configuration (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9092

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A peer node is inserted into the system.
Detailed Description
A peer node is inserted into the system.
Recommended Response Action
No response action is required.
Category
System Health (HWC = Hardware Config)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

HWC9093

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A peer node has been removed from the system.
Detailed Description
A peer node has been removed from the system.
Recommended Response Action
Insert the peer node into the system.
Category
System Health (HWC = Hardware Config)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\