PowerEdge Servers Error and Event Messages Reference Guide
PCI—PCI Device Event Messages
PCI1300
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A front panel diagnostic interrupt was detected.
- Detailed Description
- The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced.
- Recommended Response Action
- Reset the system to continue operation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1302
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus time-out was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded. The device has failed to respond to a transaction (source/target abort or completion timeout).
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1304
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An I/O channel check error was detected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- I/O channel check error detected. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1306
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A software error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Reboot the system and update the component drivers.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1308
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCI parity error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- PCI parity error on bus <bus> device <device> function <func>. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1310
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCI system error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- PCI system error on bus <bus> device <device> function <func>. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1312
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An EISA fail-safe time-out was detected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1314
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus correctable error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable re-install the device at the next scheduled service time.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1316
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus uncorrectable error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1318
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A fatal error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Do one or all the steps below: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) connect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal error on bus <bus> device <device> function <func>. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1319
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue is detected in the SSD bay arg1, Slot arg2.
- Arguments
- arg1 = bay
- arg2 = number
- Detailed Description
- A high-severity issue was detected in the SSD bay identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1320
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus fatal error was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Do one or all the steps below: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) connect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Bus fatal error on bus <bus> device <device> function <func>. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1321
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue is detected in a component of the bus arg1, device 0, function arg2.
- Arguments
- arg1 = bus
- arg2 = func
- Detailed Description
- A high-severity issue is detected in the component identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1322
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Bus performance degraded for a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded. The bus is not operating at maximum speed or width.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Bus performance degraded for a component at bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1342
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus time-out was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded. The device has failed to respond to a transaction (source/target abort or completion timeout).
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1344
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An I/O channel check error was detected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- An I/O channel check error detected. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1346
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A software error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Reboot the system and update the component drivers.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1348
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCI parity error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- PCI parity error on slot <number>. Reseat PCI card
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1350
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCI system error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- PCI system error on slot <number>. Reseat PCI card
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1354
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus correctable error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next scheduled service time.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1356
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus uncorrectable error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1358
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A fatal error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If device is removable, re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal error on slot <number>. Reseat PCI card
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1360
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A bus fatal error was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Do one or all the steps below: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) connect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Bus fatal error on slot <number>. Reseat PCI card
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1362
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Bus performance degraded for a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded. The bus is not operating at maximum speed or width.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next scheduled service time.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Bus performance degraded for a component at slot <number>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI1363
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe FATAL error in arg1.
- Arguments
- arg1 = description
- Detailed Description
- System performance may be degraded, or system may fail to operate. The description of the component failed is mentioned in message.
- Recommended Response Action
- Do one or all the steps below: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) connect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A fatal IO error detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Do one of the following:1) Update the component and device firmware, and then power cycle the server.2) Remove and reinstall the Device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal IO error on bus <bus> device <device> function <func>. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The component at bus arg1 device arg2 function arg3 recovered from a fatal IO error.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A fatal IO error detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal IO error on slot <number>. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The component at slot arg1 recovered from a fatal IO error.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Watchdog timeout event occurred on the PCIe link with segment: arg1, bus: arg2, device: arg3, and function: arg4.
- Arguments
- arg1 = seg_num
- arg2 = bus_num
- arg3 = dev_num
- arg4 = func
- Detailed Description
- The OS has stopped updating the scratchpad registers of PCIe root ports, causing a watchdog timeout.
- Recommended Response Action
- Do the following: 1) Update the component drivers and power cycle the system. 2) If device is removable, remove and re-install the device. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- LCD Message
- Watchdog timeout occurred on the PCIe link with segment <seg_num> bus <bus_num> device <dev_num> and function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Watchdog timeout event occurred because which on the PCIe link on the following segment is reset: arg1, bus: arg2, device: arg3, and function: arg4.
- Arguments
- arg1 = seg_num
- arg2 = bus_num
- arg3 = dev_num
- arg4 = func
- Detailed Description
- The operating system has stopped updating the scratchpad registers of PCIe root ports, causing a watchdog timeout.
- Recommended Response Action
- No response action is required because the server is configured to automatically reset the link when timed out (ResetLinkOnTimeout).
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- LCD Message
- A Watchdog timeout event occurred because which on the PCIe link on the following segment is reset: <seg_num>, bus: <bus_num>, device: <dev_num>, and function: <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI2006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Holding IO card arg1 is reset because the PCIe link watchdog timed out.
- Arguments
- arg1 = IO_Card
- Detailed Description
- The operating system has stopped updating the scratchpad registers of PCIe root ports, causing a watchdog timeout.
- Recommended Response Action
- No response action is required because the server is configured to automatically reset the Hold IO Card when timed out (HoldIOCardInReset).
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- LCD Message
- The Holding IO card <IO_Card> is reset because the PCIe link watchdog timed out.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress.
- Detailed Description
- Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support FlexAddress.
- Recommended Response Action
- Update BIOS, BMC/iDRAC, and LOM firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on embedded NIC was successfully updated.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Failed to program virtual MAC address on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress.
- Recommended Response Action
- Update BIOS, BMC/iDRAC, and LOM firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Virtual MAC address for component at bus arg1 device arg2 function arg3 was successfully programed.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on mezzanine card arg1 failed to support Link Tuning or FlexAddress.
- Arguments
- arg1 = number
- Detailed Description
- Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
- Recommended Response Action
- Update BIOS, BMC/iDRAC, and mezzanine card firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on mezzanine card arg1 was successfully updated.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Failed to get Link Tuning or FlexAddress data from iDRAC.
- Detailed Description
- Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.
- Recommended Response Action
- Update BIOS, BMC/iDRAC firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Link Tuning or FlexAddress data successfully obtained.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A correctable PCIe error detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next service window.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- PCIe error on a component at bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe is operating normally on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A non-fatal IO error detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- System performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next service window.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- IO error on a component at bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The component at bus arg1 device arg2 function arg3 recovered from a non-fatal IO error.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The QuickPath Interconnect (QPI) width degraded.
- Detailed Description
- System performance may be degraded. The bus is not operating at maximum speed or width.
- Recommended Response Action
- Reset the system, if the problem persists reinstall processors.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- The QuickPath Interconnect (QPI) width degraded.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The QuickPath Interconnect (QPI) width regained.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A correctable PCIe error detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- System performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next scheduled service time.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- PCIe error on a component at slot <number>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The component at slot arg1 recovered from a non-fatal PCIe error.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress.
- Detailed Description
- Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
- Recommended Response Action
- Update BIOS, BMC/iDRAC, and mezzanine card firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Device option ROM on mezzanine card was successfully updated.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- New PCI card(s) have been detected in the system. Fan speeds may have changed to add additional cooling to the cards.
- Detailed Description
- New PCI card(s) have been detected in the system that may require additional airflow. Fan speeds may have changed to add additional cooling to the cards.
- Recommended Response Action
- Changing default fan response to PCIe cards should be done with appropriate understanding of the PCIe cooling needs of the cards present in the system. If the automatic cooling response is insufficient, additional cooling can be added by one of the following methods. 1) From iDRAC Web GUI, click Hardware -> Fans -> Setup, then from the fan speed offset drop-down list appropriately select the cooling level needed or set the minimum fan speed to a custom value. 2) From F2 System Setup, select iDRAC Settings -> Thermal, and set a higher fan speed from the fan speed offset or minimum fan speed. 3) For RACADM commands run "racadm help system.thermalsettings". If a lower fan speed is required, contact your service provider for the appropriate IPMI commands to reduce the default fan speed response for new PCIe cards.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A low-severity issue is detected in the SSD bay arg1, Slot arg2.
- Arguments
- arg1 = bay
- arg2 = number
- Detailed Description
- A low-severity issue was detected in the SSD bay identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- An issue is detected in the SSD bay <bay>, Slot <number>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A low-severity issue is detected in a component of the bus arg1, device 0, function arg2.
- Arguments
- arg1 = bus
- arg2 = func
- Detailed Description
- A low-severity issue is detected in the component identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- LCD Message
- An issue in a component of bus <bus ID>, device 0, function <function ID>.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to set the Airflow Linear Flow per Minute (LFM) custom value because the LFM Mode is not set to Custom.
- Detailed Description
- The Airflow Linear Flow per Minute (LFM) custom value cannot be set because the LFM Mode is not set to Custom.
- Recommended Response Action
- Set the Linear Flow per Minute (LFM Mode) to Custom and retry the operation. To set the LFM Mode to Custom using iDRAC GUI, navigate to Configuration -> System Settings -> Hardware Settings -> PCIe Airflow Settings page.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Warning
- LCD Message
- Unable to set the Airflow LFM custom value.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to adjust the Airflow Linear Flow per Minute (LFM) settings of the PCIe slot because the LFM settings can be adjusted only for installed cards that are identified as third party cards.
- Detailed Description
- The Airflow Linear Flow per Minute (LFM) settings of the PCIe slot cannot be adjusted because the LFM settings can be adjusted only for installed cards that are identified as third party cards.
- Recommended Response Action
- Make sure that the cards installed in the PCIe slots are third party cards.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3023
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The LFM (Linear Feet Per Minute) setting of the PCIe slot arg1 has been arg2.
- Arguments
- arg1 = slot
- arg2 = action
- Detailed Description
- The LFM (Linear Feet Per Minute) setting(s) of the PCIe slot has changed as identified in the message.
- Recommended Response Action
- Make sure that the LFM (Linear Feet Per Minute) setting(s) of the PCIe slot meets the cooling requirements of the installed PCIe device.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- An error has triggered a Downstream Port Containment event on a component at the bus, device, and function identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Downstream Port Containment event detected on a component at bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected in the SSD bay arg1, Slot arg2.
- Arguments
- arg1 = bay
- arg2 = number
- Detailed Description
- An error has triggered a Downstream Port Containment event in the SSD bay and slot identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- LCD Message
- Downstream Port Containment event detected in the SSD bay <bay>, Slot <number>.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- An error has triggered a Downstream Port Containment event in the component at the slot identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Downstream Port Containment event on slot <number>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected on a component at slot arg1.
- Arguments
- arg1 = number
- Detailed Description
- An Information-Only event was detected on a component at slot <number>.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected on a component at bus arg1 device arg2 function arg3.
- Arguments
- arg1 = bus
- arg2 = device
- arg3 = func
- Detailed Description
- An Information-Only event was detected on a component at bus <bus> device <device> function<func>.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected in the SSD bay arg1, Slot arg2.
- Arguments
- arg1 = bay
- arg2 = number
- Detailed Description
- An Information-Only event was detected in the SSD bay <bay>, Slot <number>.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- New PCI card(s) have been detected in the system. Fan speeds may have changed to add additional cooling to the cards.
- Detailed Description
- New PCI card(s) have been detected in the system that may require additional airflow. Fan speeds may have changed to add additional cooling to the cards.
- Recommended Response Action
- If the automatic cooling response is insufficient, additional cooling can be added by one of the following methods. 1) From iDRAC Web GUI, click Cooling -> Configure Fans -> PCIe Airflow Settings, then select Custom option for that PCIe slot and define desired LFM value. 2) For RACADM commands run "racadm help system.PcieSlotLFM". If automatic cooling response is above desired levels, this response can be turned off in most cases and/or a different LFM target can be set using PCIe Airflow Settings options in iDRAC GUI or Racadm. See iDRAC User Guide for more details by searching for "cooling" . Changing default fan response to PCIe cards should be done in alignment with vendor specification for PCIe cooling needs of the cards present in the system. Recommended actions may not be supported or available on all systems.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected on a component at segment arg1 bus arg2 device arg3 function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = func
- Detailed Description
- An error has triggered a Downstream Port Containment event on a component at the segment, bus, device, and function identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Downstream Port Containment event detected on a component at segment <seg> bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected in the SSD bay arg1, Slot arg2, Segment arg3.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- Detailed Description
- An error has triggered a Downstream Port Containment event in the segment, SSD bay and slot identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Downstream Port Containment event detected in the SSD bay <bay>, Slot <number>, Segment <seg>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected on a component at slot arg1 segment arg2.
- Arguments
- arg1 = number
- arg2 = seg
- Detailed Description
- An Information-Only event was detected on a component at slot <number> Segment <seg>.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected on a component at segment arg1, bus arg2, device arg3, and function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = func
- Detailed Description
- An Information-Only event was detected on a component at segment identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected in the segment arg1, SSD bay arg2, and Slot arg3.
- Arguments
- arg1 = seg
- arg2 = bay
- arg3 = number
- Detailed Description
- An Information-Only event was detected in the segment identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A correctable PCIe error is detected on a component at slot arg1 segment arg2.
- Arguments
- arg1 = number
- arg2 = seg
- Detailed Description
- A correctable PCIe error is detected on a component at the segment identified in the message. The server performance may be degraded.
- Recommended Response Action
- Update component drivers and power cycle the system. Remove and re-install the device at the next scheduled service time.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- PCIe error on a component at slot <number> segment <seg>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A correctable PCIe error is detected on a component at the segment arg1, bus arg2, device arg3, and function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = func
- Detailed Description
- A correctable PCIe error is detected on a component at the segment identified in the message.
- Recommended Response Action
- Update the component drivers and power cycle the system. Remove and re-install the device during the next scheduled service.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- PCIe error on a component at segment <seg> bus <bus> device <device> function <func>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3038
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A low-severity issue is detected in the SSD bay arg1, Slot arg2, and segment arg3.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- Detailed Description
- A low-severity issue is detected in the SSD bay identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- An issue is detected in the SSD bay <bay>, Slot <number>, segment <seg>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3039
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue is detected on a component in the slot arg1 segment arg2.
- Arguments
- arg1 = number
- arg2 = seg
- Detailed Description
- A high-severity issue is detected on a component in the slot identified in the message.
- Recommended Response Action
- Do one or all of the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Bus fatal error on slot <number> segment <seg>. Reseat PCI card.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3040
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue is detected on a component at segment arg1, bus arg2, device arg3, and function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = func
- Detailed Description
- A high-severity issue is detected on a component at the segment identified in the message.
- Recommended Response Action
- Do one or all of the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Update the device drivers. 3) Reset iDRAC. 4) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 5) If possible, remove and reinstall the device. 6) Make sure that the cables are properly routed and connected. 7) Update the OS version for patches or hotfixes. 8) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal error on segment <seg> bus <bus> device <device> function <func>. Power cycle system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3041
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue is detected in the SSD bay arg1, slot arg2, and segment arg3.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- Detailed Description
- A high-severity issue is detected in the SSD bay identified in the message.
- Recommended Response Action
- Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3042
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A fatal IO error detected on a component at segment arg1 bus arg2 device arg3 function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = func
- Detailed Description
- System performance may be degraded, or system may fail to operate.
- Recommended Response Action
- Update component drivers and power cycle the system. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- LCD Message
- Fatal IO error on segment <seg> bus <bus> device <device> function <func>. Contact support.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI3043
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event detected on a component at slot arg1 segment arg2.
- Arguments
- arg1 = number
- arg2 = seg
- Detailed Description
- An error has triggered a Downstream Port Containment event in the component at the segment and slot identified in the message. The Operating System is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Update the component drivers, firmware, and check for the available OS updates. If the issue persists, power cycle the server. For more information about the Downstream Port Containment events, see the PCI Express 5.0 Specification documentation.
- Category
- System Health (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 2418
- LCD Message
- Downstream Port Containment event on slot <number> segment <seg>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PCI5001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe card carrier containing a PCIe card is inserted in PCIe slotarg1 .
- Arguments
- arg1 = slot number
- Detailed Description
- A PCIe card carrier containing a PCIe card is present in the slot identified in the message. This PCIe card will be enabled when the associated server is turned on or power cycled.
- Recommended Response Action
- Turn on or power cycle the associated server to enable the PCIe card.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 10611
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slotarg1 .
- Arguments
- arg1 = slot number
- Detailed Description
- A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 10611
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe card carrier is removed from the PCIe slotarg1 .
- Arguments
- arg1 = slot number
- Detailed Description
- A PCIe card carrier is removed from the PCIe slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 10611
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A power fault issue is detected in the PCIe adapter that was turned on in PCIe slotarg1.
- Arguments
- arg1 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message.
- Recommended Response Action
- Make sure that: 1) The PCIe adapter used is supported by the Chassis Management Controller (CMC). For a list of supported adapters, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An auxiliary power fault issue is detected in the PCIe adapter that was turned on in PCIe slotarg1.
- Arguments
- arg1 = slot number
- Detailed Description
- Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message.
- Recommended Response Action
- Make sure that: 1) The PCIe adapter used is supported by the Chassis Management Controller (CMC). For a list of supported adapters, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The power-related issue of the PCIe adapter in slotarg1 is resolved.
- Arguments
- arg1 = slot number
- Detailed Description
- The power related issue of the PCIe device in the slot identified in the message is resolved.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The auxiliary power-related issue of the PCIe adapter in slot arg1 is resolved.
- Arguments
- arg1 = slot number
- Detailed Description
- The 3.3 Volt Regulator power related issue of PCIe carrier present in the slot identified in the message is resolved.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PCI = PCI Device)
- Severity
- Informational
- Trap/EventID
- 2419
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Chassis Management Controller (CMC) is unable to communicate with the PCIe switch board.
- Detailed Description
- The Chassis Management Controller (CMC) could not successfully connect to the PCIe switch board.
- Recommended Response Action
- Do the following: 1) Perform an AC Power Cycle operation on the Chassis by disconnecting the chassis from AC power, waiting for 30 seconds, and then reconnecting AC power. 2) Power on at least one server. Using the Chassis Management Controller (CMC) web interface, select Server Overview->Power->Control and then click the Operation field and select the Power On Server operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PCI = PCI Device)
- Severity
- Critical
- Trap/EventID
- 2417
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
PCI5009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The PCIe adapter in the PCIe slotarg1 was removed from the slot while the serverarg2 was turned-on.
- Arguments
- arg1 = PCIe slot number
- arg2 = server slot number
- Detailed Description
- Chassis Management Controller (CMC) detected that a PCIe adapter was removed from a server which was turned-on. This may cause the server operating system to stop responding or to function in an improper manner.
- Recommended Response Action
- Perform a Power Cycle operation on the associated server. Restarting the operating system will not resolve this issue. Only remove PCIe adapters when the associated server is turned-off.
- Category
- Audit (PCI = PCI Device)
- Severity
- Warning
- Trap/EventID
- 8562
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*