PCON—pcard connectivity Event Messages

PCON0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
PLD is unable to link the P-Card arg1, arg2, connected to the PICPWR arg3.
Arguments
  • arg1 = Device Type
  • arg2 = Device Index
  • arg3 = PICPWR ID
Detailed Description
PLD is unable to link the P-Card identified in the message.
Recommended Response Action
Do the following and retry the operation: 1) Update the FRU firmware of the P-Card to the latest version. 2) Perform a System Reboot operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (PCON = pcard connectivity)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

PCON0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An invalid Field Replacable Unit (FRU) data is received from the P-Card connected to the PICPWR arg1.
Arguments
  • arg1 = PICPWR ID
Detailed Description
An invalid Field Replacable Unit (FRU) data is received from the P-Card connected to the PICPWR identified in the message.
Recommended Response Action
Do the following and retry the operation: 1) Update the FRU firmware of the P-Card to the latest version. 2) Perform a System Reboot operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (PCON = pcard connectivity)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\