PowerEdge Servers Error and Event Messages Reference Guide

PDF

POW—Power Usage Event Messages

POW000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, chassis infrastructure not ready.
Detailed Description
Host failed to power up because chassis infrastructure is not ready. This messages has been replaced by Message ID PWR2250.
Recommended Response Action
Check status of chassis infrastructure.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

POW001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, chassis cover open.
Detailed Description
Host failed to power up because chassis cover is open. This messages has been replaced by Message ID PWR2251.
Recommended Response Action
Check chassis cover.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

POW002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, unknown component installed in Fabric1/Fabric2.
Detailed Description
Host failed to power up because unsupported components installed in Fabric1/fabric2. This message has been replaced by Message ID PWR2252.
Recommended Response Action
Check for unsupported components installed in Fabric1/Fabric2.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

POW003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, no PCI/Mezz card installed in Fabric1/Fabric2.
Detailed Description
Host failed to power up because PCI/Mezz cards not installed in Fabric1/Fabric2. This message has been replaced by Message ID PWR2253.
Recommended Response Action
Install PCI/Mezz card in Fabric1/Fabric2.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

POW004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, unacknowledged use of 110V.
Detailed Description
Host failed to power up because of unacknowledged use of 110V. This messages has been replaced by Message ID PWR2254.
Recommended Response Action
Check for unacknowledged use of 110V.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

POW005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Power on permission error, CMC is in MPCM mode.
Detailed Description
Host failed to power up because CMC MPCM mode is enabled. This messages has been replaced by Message ID PWR2255.
Recommended Response Action
Disable MPCM mode to power up.
Category
Audit (POW = Power Usage)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\