PST0000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unrecognized Post Code.
- Detailed Description
- The BIOS provided a progress code to the iDRAC, but that progress code is not recognized by the current iDRAC firmware.
- Recommended Response Action
- Do one of the following: 1) Update the iDRAC firmware. 2) Restart the system and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Unrecognized Post Code.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System Power On.
- Detailed Description
- System BIOS detected the system is turned on.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- System Power On.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CPU Microcode load.
- Detailed Description
- System BIOS has started loading the processor microcode.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- CPU Microcode load.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chipset Initialization.
- Detailed Description
- System BIOS has started chipset initialization.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Started chipset initialization.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory Configuration.
- Detailed Description
- System BIOS has started memory configuration.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Memory configuration started.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Shadow BIOS.
- Detailed Description
- System BIOS has started copying image from flash to system memory.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Shadow BIOS operation started.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Multiprocessor Initialization.
- Detailed Description
- System BIOS has started initialization multiprocessor support.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Started multiprocessor initialization.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- POST processing start.
- Detailed Description
- System BIOS has started power on self test.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Started power on self test (POST).
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System Management Mode (SMM)initialization.
- Detailed Description
- System BIOS has started System Management Mode (SMM) initialization.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- System Management Mode (SMM) initialization.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCI bus enumeration & video initialization.
- Detailed Description
- System BIOS has started PCI bus enumeration and video initialization.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- PCI bus enumeration & video initialization.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- iDRAC is ready.
- Detailed Description
- The iDRAC initialization is completed.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- iDRAC initialization completed.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Extended Memory test started.
- Detailed Description
- System started extended memory test.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Extended memory test started.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Extended Memory test running \
- Detailed Description
- System extended memory test in progress.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Extended Memory test running \
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Extended Memory test running /
- Detailed Description
- System extended memory test in progress.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Extended Memory test running /
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Extended Memory test completed.
- Detailed Description
- System completed extended memory test.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Extended Memory test completed.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0064
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Display sign-on.
- Detailed Description
- System BIOS is displaying power on splash screen.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Display sign-on.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0065
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCI configuration.
- Detailed Description
- System BIOS is configuring PCI devices.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- PCI configuration.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0080
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An issue was detected. System at boot F1/F2 prompt. Requires entry to continue.
- Detailed Description
- System is at the F1/F2 prompt because the system BIOS detected an issue other than "No bootable devices".
- Recommended Response Action
- Check post display screen for details. Press F1 to continue boot, or press F2 to go to setup.
- Category
- System Health (PST = BIOS POST)
- Severity
- Warning
- LCD Message
- System BIOS at F1/F2 prompt.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0081
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No bootable devices.
- Detailed Description
- System is at F1/F2 prompt because the system BIOS was unable to detect a bootable device.
- Recommended Response Action
- Make sure a bootable device is attached to the system and enabled in BIOS setup. If device is attached and enabled, remove and reapply power to server. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- No bootable devices found. Check bootable devices.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0082
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- In BIOS Setup Menu.
- Detailed Description
- System is at the BIOS Setup Menu.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- In BIOS Setup Menu.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0083
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- In BIOS Boot Menu.
- Detailed Description
- System is at the BIOS Boot Menu.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- In BIOS Boot Menu.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0084
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Automated Task application.
- Detailed Description
- System started the Automated Task application.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Automated Task application.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0085
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Performing CSIOR.
- Detailed Description
- System is performing CSIOR (Collect System Inventory on Restart).
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Performing CSIOR.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0086
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- In Lifecycle Controller.
- Detailed Description
- System BIOS has launched the Lifecycle Controller user interface.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- In Lifecycle Controller.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0087
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Initializing iDRAC.
- Detailed Description
- System BIOS is initializing iDRAC.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Initializing iDRAC
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0088
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Preparing to Boot.
- Detailed Description
- System BIOS is preparing to boot the system.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Preparing to Boot.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0089
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A problem was detected during Power-On Self-Test (POST).
- Detailed Description
- A problem was detected during Power-On Self-Test (POST). The next logged message contains more specific details for the detected issue.
- Recommended Response Action
- Review the next logged message for the recommended response action to resolve the problem.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0090
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A problem was detected related to the previous server boot.
- Detailed Description
- A problem was detected related to the previous server boot. The next logged message contains more specific details for the detected issue.
- Recommended Response Action
- Review the next logged message for the recommended response action to resolve the problem.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0091
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A problem was detected in Memory Reference Code (MRC).
- Detailed Description
- A problem was detected in Memory Reference Code (MRC). The next logged message contains more specific details for the detected issue.
- Recommended Response Action
- Review the next logged message for the recommended response action to resolve the problem.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0125
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system BIOS is about to start a boot option.
- Detailed Description
- The System BIOS is starting to identify, and then boot to a device.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- The system BIOS is about to start a boot option.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0126
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Giving control to UEFI aware OS.
- Detailed Description
- System is currently booting to an UEFI compatible operating system. No more POST codes will be generated in this boot sequence.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Giving control to UEFI aware OS.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0127
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Giving control to OS.
- Detailed Description
- System BIOS gave control to the operating system.
- Recommended Response Action
- No response action is required.
- Category
- System Health (PST = BIOS POST)
- Severity
- Informational
- LCD Message
- Giving control to OS.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0128
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No memory is detected.
- Detailed Description
- System BIOS was unable to detect memory in the system . This exception occurred early in system power on, thus the system may not display video (BIOS Post Exception 80).
- Recommended Response Action
- Inspect System Memory.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- No memory is detected. Inspect memory devices
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0129
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory is detected, but is not configurable.
- Detailed Description
- System BIOS detected memory, but was unable to configure the memory for system operation. Compare system memory installation to supported system memory configurations. Reduce the system to minimum memory configuration if acceptable. This exception occurred early in system power on, thus the system may not display video.(BIOS POST Exception Code 81).
- Recommended Response Action
- Compare system memory installation to supported system memory configurations.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Memory is detected, but is not configurable. Check memory devices
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0130
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory is configured, but not usable.
- Detailed Description
- During memory configuration system BIOS encountered device failures or speed configurations that resulted in unused memory. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 82).
- Recommended Response Action
- Remove input power. Reseat memory devices or reduce system to minimum supported memory configuration.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Memory is configured, but not usable. Check memory devices
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0131
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System BIOS shadow failed.
- Detailed Description
- Memory errors occurred copying BIOS image into system memory. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception Code 83).
- Recommended Response Action
- Remove input power. Reduce system memory to minimum configuration and apply input power.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- System BIOS shadow failed. Check memory devices
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0132
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CMOS failed.
- Detailed Description
- System BIOS detected a failure with CMOS memory during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception Code 84).
- Recommended Response Action
- Check system event log for CMOS battery exceptions. Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- CMOS failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0133
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- DMA controller failed.
- Detailed Description
- System BIOS detected a failure with the DMA controller during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 85).
- Recommended Response Action
- Remove and reapply input power.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- DMA controller failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0134
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Interrupt controller failed.
- Detailed Description
- System BIOS detected a failure with the interrupt controller during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 86).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Interrupt controller failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0135
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Timer refresh failed.
- Detailed Description
- System BIOS detected a timer refresh failure during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 87).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Timer refresh failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0136
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Programmable interval timer error.
- Detailed Description
- System BIOS detected an failure with the programmable interval timer during POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 88).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Programmable interval timer error. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0137
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Parity error.
- Detailed Description
- System BIOS detected a parity error during post This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 89).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Parity error. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0138
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- SuperIO failed.
- Detailed Description
- System BIOS detected a failure with the SIO. This exception occurred early in system power on, thus the system may not display video. (BIOS POST code exception code 8A).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- SuperIO failure. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0139
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Keyboard controller failed.
- Detailed Description
- System BIOS detected a failure with the Keyboard Controller. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 8B).
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Keyboard controller failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0140
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System management interrupt initialization failed.
- Detailed Description
- System BIOS failed to initialize the system management interrupt. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 8C) .
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- SMI initialization failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0141
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- QuickPath Interconnect (QPI) fatal error.
- Detailed Description
- Quick Path Interconnect failed during system POST. Reboot the system. If problem persists, remove input power and reseat processors. This exception occurred early in system power on, thus the system may not display video.
- Recommended Response Action
- Reboot the system. If problem persists, remove input power and reseat processors.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- QuickPath Interconnect (QPI) fatal error. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0142
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- MRC fatal error.
- Detailed Description
- BIOS Memory testing failed. Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration. This exception occurred early in system power on, thus the system may not display video.
- Recommended Response Action
- Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Memory initialization error. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0143
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel Trusted Execution Technology (TXT) fatal error.
- Detailed Description
- TXT boot failed. This could be related to memory errors or an error with the system TXT configuration. A socketed TPM module may have been removed. This exception occurred early in system power on, thus the system may not display video.
- Recommended Response Action
- Check TPM presence. Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Intel Trusted Execution Technology (TXT) fatal error. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0144
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to load required BIOS files.
- Detailed Description
- System BIOS is unable to load the required BIOS files.
- Recommended Response Action
- Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- Unable to load required BIOS files.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0192
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Shut-down test failed.
- Detailed Description
- System BIOS shutdown test failed during POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C0).
- Recommended Response Action
- Check system event log for CMOS battery exceptions. Remove and reapply input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Shut-down test failed. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0193
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- BIOS POST memory test failed.
- Detailed Description
- System BIOS POST memory test failed. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C1).
- Recommended Response Action
- Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- BIOS POST memory test failed. Check memory devices
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0194
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Remote access controller configuration failed.
- Detailed Description
- System BIOS could not configure the Remote Access controller This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C2).
- Recommended Response Action
- Power cycle the system. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Remote access controller configuration failed. Check screen message
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0195
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CPU configuration failed.
- Detailed Description
- The current processor configuration is unsupported or encountered a fatal exception during POST. Check the processor configuration. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C3).
- Recommended Response Action
- Review system processor configuration and reduce the system to the minimum configuration.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- CPU configuration failed. Check screen message
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0196
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Incorrect memory configuration.
- Detailed Description
- System BIOS detected an invalid memory population. Reinstall the memory to match the supported population. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code C4).
- Recommended Response Action
- Re-install memory to match supported memory configuration.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- Incorrect memory configuration. Review User Guide
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0208
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System BIOS has halted.
- Detailed Description
- System BIOS has halted and is unable to continue.
- Recommended Response Action
- Do one of the following: 1) If new hardware has been added, remove the new hardware and restart the server, 2) Turn server off and back on using the power button, or 3) Remove and reapply server input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- System BIOS has halted. Check console for details.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0209
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System BIOS has halted due to Non-Maskable Interrupt (NMI).
- Detailed Description
- System BIOS has halted and is unable to continue. System BIOS has detected a Non-Maskable Interrupt (NMI) which may have been caused by a hardware change.
- Recommended Response Action
- Do one of the following: 1) If new hardware has been added, remove the new hardware and restart the server, 2) Turn server off and back on using the power button, or 3) Remove and reapply server input power. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- System halted due to NMI: Check Console for Details
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0210
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A high-severity issue has occurred at the Power-On Self-Test (POST) phase which has resulted in the system BIOS to abruptly stop functioning.
- Detailed Description
- A high-severity issue has occurred at the Power-On Self-Test (POST) phase which has resulted in the system BIOS to abruptly stop functioning. BIOS is unable to report the issue on the POST screen.
- Recommended Response Action
- Power cycle the system. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- LCD Message
- The system BIOS abruptly stopped functioning because of a high-severity issue in POST.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0254
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- General failure after video.
- Detailed Description
- System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code FE).
- Recommended Response Action
- Check system video and review event log for additional information.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- General failure after video. Check screen message
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0256
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- POST fatal error detected.
- Detailed Description
- System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details.
- Recommended Response Action
- Check system video and review event log for additional information.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- POST fatal error detected. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0257
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The AMD Platform Security Processor (PSP) detected an issue during platform initialization.
- Detailed Description
- The AMD Platform Security Processor (PSP) detected an issue during platform initialization.
- Recommended Response Action
- Do one of the following: 1) Power off the server, then power on by using the power button. 2) Disconnect the input power, and then reconnect. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- The AMD Platform Security Processor (PSP) detected an issue during platform initialization.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
PST0258
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The AMD Platform Security Processor (PSP) detected a security-related issue while booting the server.
- Detailed Description
- The AMD Platform Security Processor (PSP) detected a security-related issue while booting the server and paused the server from further booting.
- Recommended Response Action
- Do one of the following: 1) Power off the server, then power on by using the power button. 2) Disconnect the input power, and then reconnect. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (PST = BIOS POST)
- Severity
- Critical
- Trap/EventID
- 2425
- LCD Message
- The AMD Platform Security Processor (PSP) detected a security-related issue while booting the server.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\