PowerEdge Servers Error and Event Messages Reference Guide

PDF

SEL—System Event Log Event Messages

SEL0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Logging is disabled.
Detailed Description
This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h).
Recommended Response Action
If unintended, re-enable logging.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Logging is enabled.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Log cleared.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
All event logging is disabled.
Detailed Description
This message appears when all event logging has been disabled by the user. (IPMI sensor type code 10h - offset 03h).
Recommended Response Action
If unintended, re-enable logging.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
All event logging is enabled.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System event log (SEL) is full.
Detailed Description
When the event log is full, additional events are not written to the log; or older events will be overwritten and lost. This message may also appear if the user disabled event logging. (IPMI sensor type code 10h - offset 04h).
Recommended Response Action
Backup and clear log.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
LCD Message
SEL is full. Review & clear log
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System event log (SEL) is almost full.
Detailed Description
When the event log is full, additional events are not written to the log or older events will be overwritten and lost. (IPMI sensor type code 10h - offset 05h).
Recommended Response Action
Backup and clear log at the next maintained time.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Could not create or initialize the system event log.
Detailed Description
If the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions.
Recommended Response Action
Reboot the management controller or iDRAC. Cycle system input power. If problem persists call support.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system event log was created or initialized successfully.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL0014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The System Event Log (SEL) was cleared by arg1 from arg2.
Arguments
  • arg1 = username
  • arg2 = IP address
Detailed Description
The System Event Log (SEL) was cleared by the username identified in the message from the IP address identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1200

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system was reconfigured.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1202

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
OEM system boot.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1204

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown system hardware failure detected.
Detailed Description
The operating system or BIOS detected an unknown event. (IPMI sensor type code 12h - offset 02h).
Recommended Response Action
Reduce system to minimum supported configuration. If issues persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
LCD Message
Unknown system hardware failure. Contact support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

SEL1205

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The unknown system hardware failure was corrected.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

SEL1206

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An entry was added to auxiliary log.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1207

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An entry was removed from auxiliary log.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1208

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A platform event filter action was executed.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1209

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The platform event filter action failed.
Detailed Description
System policies or permissions may prevent the action from executing. If configured, the system will not execute the action on a platform event (power down, cycle, interrupt, send alert).
Recommended Response Action
Review platform event configuration.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1210

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The time-stamp clock is synchronized.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1211

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The time-stamp clock could not be synchronized.
Detailed Description
The time stamp on system event log events may not correlate to the system time. (IPMI sensor type code 12h - offset 05h).
Recommended Response Action
Cycle system input power, if problem persists call support.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1300

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
No bootable media found.
Detailed Description
System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h).
Recommended Response Action
Check system boot settings. Check mass storage controller configuration settings is applicable.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1301

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Bootable media found.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1302

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Non-bootable diskette detected.
Detailed Description
The disk in the drive is not formatted correctly or does not contain the necessary operating system files(IPMI sensor type code 1eh - offset 01h).
Recommended Response Action
Replace diskette with bootable disk.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1303

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Bootable diskette detected.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1304

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The PXE server not found.
Detailed Description
PXE is one way to boot a system from the network. (IPMI sensor type code 1eh - offset 02h).
Recommended Response Action
Check network and PXE server configuration.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1305

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The PXE server found.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1306

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Invalid boot sector found.
Detailed Description
The disk in the drive is not formatted correctly or does not contain the necessary operating system files (IPMI sensor type code 1eh - offset 03h).
Recommended Response Action
Replace diskette with bootable disk.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1307

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Boot sector found.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1308

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A time-out occurred while waiting for user to select a boot source.
Detailed Description
The system has failed to boot to an operating system and needs the user to select a boot source. (IPMI sensor type code 1eh - offset 04h).
Recommended Response Action
Select boot source within the time allowed.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1309

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
User selected a boot source.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1400

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The platform generated a page alert.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1402

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The platform generated a LAN alert.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1404

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A platform event trap (PET) was generated.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1406

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The platform generated a SNMP trap.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1500

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis management controller/Management Module (CMC/MM) is redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis management controller/Management Module (CMC/MM) redundancy is lost.
Detailed Description
An action or failure has taken place that breaks CMC/MM redundancy. This includes loss of network connection, hardware failures, firmware update, firmware mismatch between CMCs/MMs, CMC/MM reset, and unplugging a CMC/MM.
Recommended Response Action
Check CMC/MM network cables and network connections. Check that CMC/MM firmware versions match.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Chassis management controller/Management Module (CMC/MM) redundancy is degraded.
Detailed Description
An action or failure has taken place that degrades CMC/MM redundancy. This includes firmware mismatch between CMCs/MMs and a CMC/MM missing SD card.
Recommended Response Action
Chassis management controller/Management Module (CMC/MM) redundancy is degraded.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis management controller/Management Module (CMC/MM) is not redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1504

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The chassis management controller/Management Module (CMC/MM) is not redundant. Insufficient resources to maintain normal operations.
Detailed Description
There is not enough available power for two CMCs/MMs to operate.
Recommended Response Action
Check overall power consumption and power status.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1506

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Lost communications with Chassis Group Member arg1.
Arguments
  • arg1 = number
Detailed Description
The primary CMC/MM has lost communication with the indicated member CMC/MM.
Recommended Response Action
Check network cable and network connections.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1507

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Communications restored with Chassis Group Member arg1.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1508

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Member arg1 could not join the Chassis Group.
Arguments
  • arg1 = number
Detailed Description
The indicated member may be a member of another chassis group or may be incompatible with membership.
Recommended Response Action
1) Check that the Name or IP address, User Name, and Password of the member are correct. 2) Check that the member is not a leader or member of another group. 3) Check that the member can be reached by the leader.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1509

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Member arg1 has joined the Chassis Group.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1510

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An authentication error detected for Chassis Group Member arg1.
Arguments
  • arg1 = number
Detailed Description
Group leaderCMC/MM could not log into the group member CMC/MM.
Recommended Response Action
Check login credentials of CMC/MM.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1511

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Member arg1 removed from the Chassis Group.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*

SEL1512

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Chassis Controller/Management Module is not responding or is not inserted properly. The status of Chassis Controller/Management Module is critical.
Detailed Description
The Chassis Controller/Management Module is not responding or is not inserted properly.
Recommended Response Action
Do one of the following: 1) Reinsert Chassis Controller/Management Module, if removed. 2) If Chassis Controller/Management Module is present but is not responding, reset the Chassis Controller/Management Module. To reset the Chassis Controller/Management Module using the graphical user interface (GUI), click Chassis Overview > Power > Control > Reset CMC/MM. To reset by running the RACADM command at the command line interface (CLI), enter: "racadm racreset".
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

SEL1513

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The status of Chassis Controller has changed from critical to OK.
Detailed Description
The iDRAC communication link to Chassis Controller is restored. Any issues related to network communication between Chassis Controller and iDRAC, incorrectly seated Chassis Controller, or unavailability of Chassis Controller is now resolved successfully.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

SEL1514

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the temperature from the inlet temperature sensor because of internal issues. This condition may impact server performance.
Detailed Description
The inlet temperature sensor measures the temperature of air entering the system. The inlet temperature is located on the front of the server, either in the control panel, right control panel or right rack ear, or front IO module. iDRAC is unable to read temperatures from this sensor because of an issue in the control panel, the cable that connects the control panel or the iDRAC firmware.
Recommended Response Action
Do one or all of the following: 1) Perform a virtual AC Cycle or disconnect and reconnect the input power cords. 2) Manually remove and reinstall the cable that connects the control panel, right control panel, and front IO module. 3) Update iDRAC firmware to the latest version available.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
LCD Message
The Inlet Temp sensor is not responding because it is damaged or has failed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle
Applicable Event or Alert Types
CMC—Not Applicable

SEL1515

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
One of the I2C sensor is not responding or is not working properly. The status of Sensor health is critical.
Detailed Description
An I2C sensor is not responding either because it is damaged, or because of damaged circuit lines for I2C bus, or a faulty sensor state.
Recommended Response Action
To find the sensor number that is not responding, type "racadm getsel -E" and check the Event Data Byte 1. To recover the sensor from the faulty state, do one of the following: 1) Reset iDRAC: a) By using graphical user interface (GUI), click Overview > Server > Quick Launch Tasks > Reset iDRAC. b) by running RACADM command at the command line interface (CLI), enter racadm racreset. 2) Change the corresponding I2C sensor by contacting your service provider.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
LCD Message
An I2C sensor is not responding because it is damaged or has failed.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

SEL1516

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sleds are automatically turned off because of a power button press simulation triggered by Chassis Controller.
Detailed Description
The sleds are automatically turned off because of a power button press simulation triggered by Chassis Controller. An I2C sensor in not correctly responding because of a corrupted signal in the sensor.
Recommended Response Action
Check the firmware version of Fan Controller Block (FCB) and make sure that the Power Supply Unit (PSU) is functional. For more information about the firmware version and PSU ratings, see PSQN SLN300669 available on the support site.
Category
System Health (SEL = System Event Log)
Severity
Critical
LCD Message
Sleds are turned off based on a power button press simulation triggered by Chassis Controller.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1517

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The sleds are automatically turned off because of a power button release simulation triggered by Chassis Controller.
Detailed Description
The sleds are automatically turned off because of a power button release simulation triggered by Chassis Controller. An I2C sensor in not correctly responding because of a corrupted signal in the sensor.
Recommended Response Action
Check the firmware version of Fan Controller Block (FCB) and make sure that the Power Supply Unit (PSU) is functional. For more information about the firmware version and PSU ratings, see PSQN SLN300669 available on the support site.
Category
System Health (SEL = System Event Log)
Severity
Critical
LCD Message
Sleds are turned off based on a power button release simulation triggered by Chassis Controller.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1518

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The performance of CPUarg1 is automatically readjusted by Chassis Controller because of unacceptable change in the thermal and power conditions.
Arguments
  • arg1 = number
Detailed Description
The performance of the CPU identified in the message is automatically readjusted by the Chassis Manager(CM) because of an unacceptable change in the thermal and power conditions. This issue is reported when the power cableis disconnected from the PSU, and it also depends on the residual power to log in to the server.
Recommended Response Action
Check the firmware version of Chassis Manager(CM) and make sure that the Power Supply Unit (PSU) is functional.
Category
System Health (SEL = System Event Log)
Severity
Critical
LCD Message
The CPU performance of CPU<number> is automatically readjusted by Chassis Controller.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1519

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The performance of CPUarg1 that was automatically readjusted by Chassis Controller is functioning normally.
Arguments
  • arg1 = number
Detailed Description
The performance of CPU identified in the message, which was automatically readjusted by Chassis Controller, is functioning normally.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
LCD Message
The CPU<number> is now operating normally.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL1520

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to synchronize arg1 Settings between arg2. Power loss detection redundancy is degraded.
Arguments
  • arg1 = Component name
  • arg2 = MM Name
Detailed Description
NVDIMM Settings could not be synchronized across Management Modules.
Recommended Response Action
Reboot from OME - Modular GUI, physically reseat or initiate a firmware update on the standby Management Module.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1521

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 Settings have been synchronized between arg2.
Arguments
  • arg1 = Component Name
  • arg2 = MM Name
Detailed Description
NVDIMM settings have been synchronized across Management Modules.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1522

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A firmware mismatch detected in arg1.
Arguments
  • arg1 = Component Name
Detailed Description
An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
Recommended Response Action
Initiate a firmware update from Management Module UI for the component identified in the message.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1523

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to detect network connection of arg1 in slot arg2.
Arguments
  • arg1 = Component Name
  • arg2 = slot number
Detailed Description
An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
Recommended Response Action
Ensure network cables are connected to external network on Management Module as identified in the message and the link is up.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1524

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
arg1 in slot arg2 is offline.
Arguments
  • arg1 = Component Name
  • arg2 = slot number
Detailed Description
An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
Recommended Response Action
If the issue persists for several minutes , perform a reset operation for the Management Module as identified in the message.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1550

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The flash device in the slot arg1 is corrupted. A recovery operation is initiated.
Arguments
  • arg1 = Component Name
Detailed Description
The flash device in the slot identified in the message is corrupted. A recovery operation is initiated.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Warning
Trap/EventID
2378
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, Remote System Log*, LC Log*

SEL1551

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The corrupted flash device in the slot arg1 is successfully recovered.
Arguments
  • arg1 = Component Name
Detailed Description
The corrupted flash device in the slot identified in the message is successfully recovered.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, Remote System Log*, LC Log*

SEL1552

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Flash corruption occurred in the slot arg1, and OpenManage Enterprise - Modular performs another firmware update operation to recover from the flash corruption.
Arguments
  • arg1 = Component Name
Detailed Description
The Flash corruption occurred in the slot identified in the message during firmware update. OpenManage Enterprise - Modular performs another firmware update operation to recover from the flash corruption.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Trap/EventID
2379
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Filter Visibility, Remote System Log*, LC Log*

SEL1553

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the recovery operation on the corrupted flash device in the slot arg1 because of an internal error.
Arguments
  • arg1 = Component Name
Detailed Description
The recovery operation on the corrupted flash device identified in the message cannot be completed because of an internal error.
Recommended Response Action
Update the OpenManage Enterprise-Modular firmware to the latest. If the issue persists, replace the Management Module by contacting your service provider. For more information about updating the firmware, refer to the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1554

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The flash device in the slot arg1 is corrupted because of an internal error.
Arguments
  • arg1 = Component Name
Detailed Description
The device identified in the message is corrupted because of an internal error.
Recommended Response Action
Retry updating the OpenManage Enterprise-Modular firmware to the latest. If the issue persists, replace the Management Module by contacting your service provider. For more information about updating the firmware, refer to the OpenManage Enterprise-Modular Users Guide available on the support site.
Category
System Health (SEL = System Event Log)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
No alerts are applicable for this message

SEL1600

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unexpected system shutdown operation occurred when collecting the internal error log data.
Detailed Description
An unexpected system shutdown operation occurred when collecting the internal error log data.
Recommended Response Action
If the shutdown operation is initiated by the user then no further action is required. Else, review the System Event log, Lifecycle logs, and OS logs to identify the possible issue that is causing the shutdown.
Category
System Health (SEL = System Event Log)
Severity
Critical
Trap/EventID
2377
LCD Message
System shutdown during internal error log collection.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

SEL9900

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unsupported event occurred.
Detailed Description
The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
Upgrade Management Software.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL9901

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
OEM software event.
Detailed Description
The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
See product documentation for additional information.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

SEL9902

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
System software event.
Detailed Description
Software on the system has logged an event that cannot be determined. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (SEL = System Event Log)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\