PowerEdge Servers Error and Event Messages Reference Guide
SEL—System Event Log Event Messages
SEL0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Logging is disabled.
- Detailed Description
- This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h).
- Recommended Response Action
- If unintended, re-enable logging.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Logging is enabled.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Log cleared.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- All event logging is disabled.
- Detailed Description
- This message appears when all event logging has been disabled by the user. (IPMI sensor type code 10h - offset 03h).
- Recommended Response Action
- If unintended, re-enable logging.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- All event logging is enabled.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System event log (SEL) is full.
- Detailed Description
- When the event log is full, additional events are not written to the log; or older events will be overwritten and lost. This message may also appear if the user disabled event logging. (IPMI sensor type code 10h - offset 04h).
- Recommended Response Action
- Backup and clear log.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- LCD Message
- SEL is full. Review & clear log
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System event log (SEL) is almost full.
- Detailed Description
- When the event log is full, additional events are not written to the log or older events will be overwritten and lost. (IPMI sensor type code 10h - offset 05h).
- Recommended Response Action
- Backup and clear log at the next maintained time.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Could not create or initialize the system event log.
- Detailed Description
- If the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions.
- Recommended Response Action
- Reboot the management controller or iDRAC. Cycle system input power. If problem persists call support.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system event log was created or initialized successfully.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL0014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The System Event Log (SEL) was cleared by arg1 from arg2.
- Arguments
- arg1 = username
- arg2 = IP address
- Detailed Description
- The System Event Log (SEL) was cleared by the username identified in the message from the IP address identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1200
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system was reconfigured.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1202
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- OEM system boot.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1204
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unknown system hardware failure detected.
- Detailed Description
- The operating system or BIOS detected an unknown event. (IPMI sensor type code 12h - offset 02h).
- Recommended Response Action
- Reduce system to minimum supported configuration. If issues persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- LCD Message
- Unknown system hardware failure. Contact support
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1205
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The unknown system hardware failure was corrected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1206
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An entry was added to auxiliary log.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1207
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An entry was removed from auxiliary log.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1208
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A platform event filter action was executed.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1209
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The platform event filter action failed.
- Detailed Description
- System policies or permissions may prevent the action from executing. If configured, the system will not execute the action on a platform event (power down, cycle, interrupt, send alert).
- Recommended Response Action
- Review platform event configuration.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1210
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The time-stamp clock is synchronized.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1211
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The time-stamp clock could not be synchronized.
- Detailed Description
- The time stamp on system event log events may not correlate to the system time. (IPMI sensor type code 12h - offset 05h).
- Recommended Response Action
- Cycle system input power, if problem persists call support.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1300
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No bootable media found.
- Detailed Description
- System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h).
- Recommended Response Action
- Check system boot settings. Check mass storage controller configuration settings is applicable.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1301
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Bootable media found.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1302
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Non-bootable diskette detected.
- Detailed Description
- The disk in the drive is not formatted correctly or does not contain the necessary operating system files(IPMI sensor type code 1eh - offset 01h).
- Recommended Response Action
- Replace diskette with bootable disk.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1303
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Bootable diskette detected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1304
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The PXE server not found.
- Detailed Description
- PXE is one way to boot a system from the network. (IPMI sensor type code 1eh - offset 02h).
- Recommended Response Action
- Check network and PXE server configuration.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1305
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The PXE server found.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1306
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid boot sector found.
- Detailed Description
- The disk in the drive is not formatted correctly or does not contain the necessary operating system files (IPMI sensor type code 1eh - offset 03h).
- Recommended Response Action
- Replace diskette with bootable disk.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1307
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Boot sector found.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1308
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A time-out occurred while waiting for user to select a boot source.
- Detailed Description
- The system has failed to boot to an operating system and needs the user to select a boot source. (IPMI sensor type code 1eh - offset 04h).
- Recommended Response Action
- Select boot source within the time allowed.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1309
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- User selected a boot source.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1400
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The platform generated a page alert.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1402
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The platform generated a LAN alert.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1404
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A platform event trap (PET) was generated.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1406
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The platform generated a SNMP trap.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1500
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The chassis management controller/Management Module (CMC/MM) is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1501
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis management controller/Management Module (CMC/MM) redundancy is lost.
- Detailed Description
- An action or failure has taken place that breaks CMC/MM redundancy. This includes loss of network connection, hardware failures, firmware update, firmware mismatch between CMCs/MMs, CMC/MM reset, and unplugging a CMC/MM.
- Recommended Response Action
- Check CMC/MM network cables and network connections. Check that CMC/MM firmware versions match.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1502
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis management controller/Management Module (CMC/MM) redundancy is degraded.
- Detailed Description
- An action or failure has taken place that degrades CMC/MM redundancy. This includes firmware mismatch between CMCs/MMs and a CMC/MM missing SD card.
- Recommended Response Action
- Chassis management controller/Management Module (CMC/MM) redundancy is degraded.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1503
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The chassis management controller/Management Module (CMC/MM) is not redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1504
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The chassis management controller/Management Module (CMC/MM) is not redundant. Insufficient resources to maintain normal operations.
- Detailed Description
- There is not enough available power for two CMCs/MMs to operate.
- Recommended Response Action
- Check overall power consumption and power status.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1506
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Lost communications with Chassis Group Member arg1.
- Arguments
- arg1 = number
- Detailed Description
- The primary CMC/MM has lost communication with the indicated member CMC/MM.
- Recommended Response Action
- Check network cable and network connections.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1507
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Communications restored with Chassis Group Member arg1.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1508
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Member arg1 could not join the Chassis Group.
- Arguments
- arg1 = number
- Detailed Description
- The indicated member may be a member of another chassis group or may be incompatible with membership.
- Recommended Response Action
- 1) Check that the Name or IP address, User Name, and Password of the member are correct. 2) Check that the member is not a leader or member of another group. 3) Check that the member can be reached by the leader.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1509
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Member arg1 has joined the Chassis Group.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1510
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An authentication error detected for Chassis Group Member arg1.
- Arguments
- arg1 = number
- Detailed Description
- Group leaderCMC/MM could not log into the group member CMC/MM.
- Recommended Response Action
- Check login credentials of CMC/MM.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1511
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Member arg1 removed from the Chassis Group.
- Arguments
- arg1 = number
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
SEL1512
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Chassis Controller/Management Module is not responding or is not inserted properly. The status of Chassis Controller/Management Module is critical.
- Detailed Description
- The Chassis Controller/Management Module is not responding or is not inserted properly.
- Recommended Response Action
- Do one of the following: 1) Reinsert Chassis Controller/Management Module, if removed. 2) If Chassis Controller/Management Module is present but is not responding, reset the Chassis Controller/Management Module. To reset the Chassis Controller/Management Module using the graphical user interface (GUI), click Chassis Overview > Power > Control > Reset CMC/MM. To reset by running the RACADM command at the command line interface (CLI), enter: "racadm racreset".
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1513
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The status of Chassis Controller has changed from critical to OK.
- Detailed Description
- The iDRAC communication link to Chassis Controller is restored. Any issues related to network communication between Chassis Controller and iDRAC, incorrectly seated Chassis Controller, or unavailability of Chassis Controller is now resolved successfully.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1514
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to read the temperature from the inlet temperature sensor because of internal issues. This condition may impact server performance.
- Detailed Description
- The inlet temperature sensor measures the temperature of air entering the system. The inlet temperature is located on the front of the server, either in the control panel, right control panel or right rack ear, or front IO module. iDRAC is unable to read temperatures from this sensor because of an issue in the control panel, the cable that connects the control panel or the iDRAC firmware.
- Recommended Response Action
- Do one or all of the following: 1) Perform a virtual AC Cycle or disconnect and reconnect the input power cords. 2) Manually remove and reinstall the cable that connects the control panel, right control panel, and front IO module. 3) Update iDRAC firmware to the latest version available.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- LCD Message
- The Inlet Temp sensor is not responding because it is damaged or has failed.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1515
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One of the I2C sensor is not responding or is not working properly. The status of Sensor health is critical.
- Detailed Description
- An I2C sensor is not responding either because it is damaged, or because of damaged circuit lines for I2C bus, or a faulty sensor state.
- Recommended Response Action
- To find the sensor number that is not responding, type "racadm getsel -E" and check the Event Data Byte 1. To recover the sensor from the faulty state, do one of the following: 1) Reset iDRAC: a) By using graphical user interface (GUI), click Overview > Server > Quick Launch Tasks > Reset iDRAC. b) by running RACADM command at the command line interface (CLI), enter racadm racreset. 2) Change the corresponding I2C sensor by contacting your service provider.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- LCD Message
- An I2C sensor is not responding because it is damaged or has failed.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1516
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The sleds are automatically turned off because of a power button press simulation triggered by Chassis Controller.
- Detailed Description
- The sleds are automatically turned off because of a power button press simulation triggered by Chassis Controller. An I2C sensor in not correctly responding because of a corrupted signal in the sensor.
- Recommended Response Action
- Check the firmware version of Fan Controller Block (FCB) and make sure that the Power Supply Unit (PSU) is functional. For more information about the firmware version and PSU ratings, see PSQN SLN300669 available on the support site.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- LCD Message
- Sleds are turned off based on a power button press simulation triggered by Chassis Controller.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1517
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The sleds are automatically turned off because of a power button release simulation triggered by Chassis Controller.
- Detailed Description
- The sleds are automatically turned off because of a power button release simulation triggered by Chassis Controller. An I2C sensor in not correctly responding because of a corrupted signal in the sensor.
- Recommended Response Action
- Check the firmware version of Fan Controller Block (FCB) and make sure that the Power Supply Unit (PSU) is functional. For more information about the firmware version and PSU ratings, see PSQN SLN300669 available on the support site.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- LCD Message
- Sleds are turned off based on a power button release simulation triggered by Chassis Controller.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1518
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The performance of CPUarg1 is automatically readjusted by Chassis Controller because of unacceptable change in the thermal and power conditions.
- Arguments
- arg1 = number
- Detailed Description
- The performance of the CPU identified in the message is automatically readjusted by the Chassis Manager(CM) because of an unacceptable change in the thermal and power conditions. This issue is reported when the power cableis disconnected from the PSU, and it also depends on the residual power to log in to the server.
- Recommended Response Action
- Check the firmware version of Chassis Manager(CM) and make sure that the Power Supply Unit (PSU) is functional.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- LCD Message
- The CPU performance of CPU<number> is automatically readjusted by Chassis Controller.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1519
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The performance of CPUarg1 that was automatically readjusted by Chassis Controller is functioning normally.
- Arguments
- arg1 = number
- Detailed Description
- The performance of CPU identified in the message, which was automatically readjusted by Chassis Controller, is functioning normally.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- LCD Message
- The CPU<number> is now operating normally.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL1520
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to synchronize arg1 Settings between arg2. Power loss detection redundancy is degraded.
- Arguments
- arg1 = Component name
- arg2 = MM Name
- Detailed Description
- NVDIMM Settings could not be synchronized across Management Modules.
- Recommended Response Action
- Reboot from OME - Modular GUI, physically reseat or initiate a firmware update on the standby Management Module.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1521
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 Settings have been synchronized between arg2.
- Arguments
- arg1 = Component Name
- arg2 = MM Name
- Detailed Description
- NVDIMM settings have been synchronized across Management Modules.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1522
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A firmware mismatch detected in arg1.
- Arguments
- arg1 = Component Name
- Detailed Description
- An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
- Recommended Response Action
- Initiate a firmware update from Management Module UI for the component identified in the message.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1523
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to detect network connection of arg1 in slot arg2.
- Arguments
- arg1 = Component Name
- arg2 = slot number
- Detailed Description
- An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
- Recommended Response Action
- Ensure network cables are connected to external network on Management Module as identified in the message and the link is up.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1524
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 in slot arg2 is offline.
- Arguments
- arg1 = Component Name
- arg2 = slot number
- Detailed Description
- An action or failure has taken place that breaks redundancy in the Management Module. The message identifies the exact cause.
- Recommended Response Action
- If the issue persists for several minutes , perform a reset operation for the Management Module as identified in the message.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1550
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The flash device in the slot arg1 is corrupted. A recovery operation is initiated.
- Arguments
- arg1 = Component Name
- Detailed Description
- The flash device in the slot identified in the message is corrupted. A recovery operation is initiated.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Warning
- Trap/EventID
- 2378
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, Remote System Log*, LC Log*
SEL1551
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The corrupted flash device in the slot arg1 is successfully recovered.
- Arguments
- arg1 = Component Name
- Detailed Description
- The corrupted flash device in the slot identified in the message is successfully recovered.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, Remote System Log*, LC Log*
SEL1552
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Flash corruption occurred in the slot arg1, and OpenManage Enterprise - Modular performs another firmware update operation to recover from the flash corruption.
- Arguments
- arg1 = Component Name
- Detailed Description
- The Flash corruption occurred in the slot identified in the message during firmware update. OpenManage Enterprise - Modular performs another firmware update operation to recover from the flash corruption.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Trap/EventID
- 2379
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, Remote System Log*, LC Log*
SEL1553
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the recovery operation on the corrupted flash device in the slot arg1 because of an internal error.
- Arguments
- arg1 = Component Name
- Detailed Description
- The recovery operation on the corrupted flash device identified in the message cannot be completed because of an internal error.
- Recommended Response Action
- Update the OpenManage Enterprise-Modular firmware to the latest. If the issue persists, replace the Management Module by contacting your service provider. For more information about updating the firmware, refer to the OpenManage Enterprise-Modular Users Guide available on the support site.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1554
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The flash device in the slot arg1 is corrupted because of an internal error.
- Arguments
- arg1 = Component Name
- Detailed Description
- The device identified in the message is corrupted because of an internal error.
- Recommended Response Action
- Retry updating the OpenManage Enterprise-Modular firmware to the latest. If the issue persists, replace the Management Module by contacting your service provider. For more information about updating the firmware, refer to the OpenManage Enterprise-Modular Users Guide available on the support site.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- No alerts are applicable for this message
SEL1600
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unexpected system shutdown operation occurred when collecting the internal error log data.
- Detailed Description
- An unexpected system shutdown operation occurred when collecting the internal error log data.
- Recommended Response Action
- If the shutdown operation is initiated by the user then no further action is required. Else, review the System Event log, Lifecycle logs, and OS logs to identify the possible issue that is causing the shutdown.
- Category
- System Health (SEL = System Event Log)
- Severity
- Critical
- Trap/EventID
- 2377
- LCD Message
- System shutdown during internal error log collection.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL9900
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unsupported event occurred.
- Detailed Description
- The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
- Recommended Response Action
- Upgrade Management Software.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL9901
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- OEM software event.
- Detailed Description
- The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
- Recommended Response Action
- See product documentation for additional information.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
SEL9902
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- System software event.
- Detailed Description
- Software on the system has logged an event that cannot be determined. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
- Recommended Response Action
- No response action is required.
- Category
- System Health (SEL = System Event Log)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\