PowerEdge Servers Error and Event Messages Reference Guide
STOR—Storage Event Messages
STOR001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The command is successfully run.
- Detailed Description
- The command is successfully run.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Missing parameter.
- Detailed Description
- Required parameter is missing.
- Recommended Response Action
- Refer to the RAID profile to determine required parameters.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid parameter value
- Detailed Description
- Provided parameter value is not valid.
- Recommended Response Action
- Refer to the RAID profile to determine the valid parameters values.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation.
- Detailed Description
- The operation could not be completed because of one of the following:1) The device does not support the operation.2) There is an issue with the management controller (either the iDRAC or the Chassis Management Controller/Management Module (CMC/MM)) that is managing the storage.
- Recommended Response Action
- Retry the operation. If the issue persists, the operation may not be supported. For more information, see the iDRAC Users Guide available on the support site.
- Category
- Configuration (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to allocate resources.
- Detailed Description
- The operation could not be completed because of insufficient memory space on the management controller (either the iDRAC or the Chassis Management Controller/Management Module (CMC/MM)) managing the storage.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Configuration (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because either the Fully Qualified Device Descriptor (FQDD) entered did not match any virtual drive (VD), the physical drives available, or the operation is not supported on the physical drive (s).
- Detailed Description
- The operation cannot be completed because either the Fully Qualified Device Descriptor (FQDD) entered did not match any virtual drive (VD), the physical drives available, or the operation is not supported on the physical drive (s).
- Recommended Response Action
- Make sure of the following and retry the operation: 1) A physical drive or virtual drive with the FQDD entered exists. 2) The physical drive (s) supports the operation being tried. For more information about supported physical drives, see the iDRAC Users Guide available on the support site.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation either because the RAID level entered is not supported by the controller, or the current RAIDType of "MD Software RAID" does not allow the operation.
- Detailed Description
- The operation cannot be completed either because the RAID level entered is not supported by the controller, or the current RAIDType of "MD Software RAID" does not allow the operation.
- Recommended Response Action
- Enter a valid RAID level and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No RAID controller is displayed.
- Detailed Description
- No RAID controller data to display. The system is powered off, no RAID controller is present in the system, or the RAID controller is not connected to the system.
- Recommended Response Action
- Check if the server has power, RAID controller is available, and that a RAID controller is connected to the system.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No batteries are displayed.
- Detailed Description
- No battery data to display. The system is powered off, batteries are not present on the system, batteries are not connected to the RAID controller, or the batteries are depleted.
- Recommended Response Action
- Check if the server has power, batteries are available, and batteries are connected to the RAID controller.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0103
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No physical disks are displayed.
- Detailed Description
- No physical disk data to display. The system is powered off, physical disks are not present on the system, or physical disks are not connected to the enclosure or backplane.
- Recommended Response Action
- Check if the server has power, physical disks are available, and physical disks are connected to the enclosure or backplane.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No virtual disks are displayed.
- Detailed Description
- No virtual disk data to display. The system is powered off, physical disks are not present on the system, or virtual disks are not created.
- Recommended Response Action
- Check if the server has power, physical disks are available, and virtual disks are created.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0105
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No enclosures are displayed.
- Detailed Description
- No enclosure data to display. The system is powered off, enclosures are not present on the system, or enclosures are not connected to the RAID controllers.
- Recommended Response Action
- Check if the server has power, enclosures are available, and enclosures are connected to the RAID controllers.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0106
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fans are not connected to enclosures or data about fans is unavailable.
- Detailed Description
- No fan data to display. The system is powered off, no fan enclosures are present in the system, or the fans are not connected to the enclosures.
- Recommended Response Action
- Check if the server has power, enclosure fan is available, and fan is connected to the enclosure.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0107
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- EMMs are not connected to enclosures or data about EMMs is unavailable.
- Detailed Description
- No EMMs data to display. The system is powered off, no enclosure EMMs are present, or the EMMs are not connected to the enclosures.
- Recommended Response Action
- Check if the server has power, EMMs are available, and EMMs are connected to the enclosure.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0108
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Temperature probes are not connected to enclosures or data about temperature is unavailable.
- Detailed Description
- No temperature data to display. The system is powered off, no enclosure temperature probes are present in the system, or the temperature probes are not connected to the enclosures.
- Recommended Response Action
- Check if the server has power, enclosure temperature probe is available, and temperature probe is connected to the enclosure.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0109
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Power supply unit is not connected to the enclosure or data about power supply unit is unavailable.
- Detailed Description
- No power supply unit data to display. The system is powered off, no power supply unit is present in the system, or the power supply unit is not connected to the enclosure.
- Recommended Response Action
- Check if the server has power, enclosure power supply unit is available, and power supply unit is connected to the enclosure.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Stripe size not supported on controller.
- Detailed Description
- The operation cannot be completed because the stripe size entered is not supported by the controller.
- Recommended Response Action
- Enter a valid stripe size and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0110
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid Fully Qualified Device Descriptor (FQDD).
- Detailed Description
- The specified Fully Qualified Device Descriptor (FQDDs) system component name is invalid.
- Recommended Response Action
- Verify that the correct Fully Qualified Device Descriptor (FQDD) system component name is specified. See the help text (The help text for the raid subcommand can be obtained by running "racadm help raid") or documentation for valid FQDD system component names.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0111
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid reference key.
- Detailed Description
- The specified reference key is invalid.
- Recommended Response Action
- Verify that the correct reference key is specified. See the help text or documentation for valid reference keys.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Provided Physical disk not valid for this operation.
- Detailed Description
- One or more of the specified physical disks cannot be used for the operation requested. Physical disk protocol and media type, along with other physical disk characteristics like Secure Encryption and T10 protection, need to match the requirements of the requested operation.
- Recommended Response Action
- Make sure the specified physical disk has the appropriate protocol and media type for the requested operation. Specify a different physical disk with a state appropriate for the requested operation and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more storage device(s) are not in a state where the operation can be completed.
- Detailed Description
- One or more storage device(s) are in a state that prevents the operation from completing.
- Recommended Response Action
- Make sure the specified storage devices are in a state appropriate for the requested operation and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Maximum virtual disks allowed for this controller has been reached.
- Detailed Description
- A new virtual disk cannot be created because the maximum number of virtual disks are already created.
- Recommended Response Action
- A new virtual disk cannot be created until one is deleted.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The physical disk specified is not large enough to be a hot spare for this virtual disk.
- Detailed Description
- The physical disk drive cannot be assigned as the hot-spare of this virtual disk because the capacity of the physical disk is not sufficient.
- Recommended Response Action
- Specify a physical disk with a larger capacity or replace the specified physical disk with one with more capacity, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The specified Virtual Disk is not valid for the operation.
- Detailed Description
- The virtual disk specified is not compatible with the requested operation or a specified operation parameter is not appropriate for the virtual disk type specified.
- Recommended Response Action
- Make sure the operation parameters are appropriate for the virtual disk type. Specify a compatible virtual disk for the requested operation and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No foreign configurations detected.
- Detailed Description
- This operation did not detect any foreign drives. This may be because no foreign drives are present or the only foreign drives are in a secured locked state.
- Recommended Response Action
- If the only foreign drives present are in a secured locked state, run a secure erase operation on the drives to securely erase data or unlock these drives and retry the operation. Otherwise the operation was not successful because there are no foreign drives.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The specified passphrase is not valid.
- Detailed Description
- The passphrase specified does not follow the passphrase character criteria of the controller character.
- Recommended Response Action
- Enter a passphrase that meets the passphrase character criteria of the controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A controller key is already present.
- Detailed Description
- The controller key cannot be set because a key is already present.
- Recommended Response Action
- Delete the current key and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0200
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Array Manager is installed on the system.
- Detailed Description
- Installing Storage Services and Array Manager on the same system is not a supported configuration. Storage Services is not installed on a system where Array Manager is installed.
- Recommended Response Action
- Uninstall either Storage Services or Array Manager and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2135
- OMSA Trap ID
- 10300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0201
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to determine whether the system has the minimum required versions of the RAID controller drivers and firmware.
- Detailed Description
- Unable to determine whether the system has the minimum required versions of the RAID controller drivers.
- Recommended Response Action
- See the Readme file on the installation media for driver and firmware requirements. If Storage Services experiences performance problems, make sure that minimum supported versions of the drivers and firmware are installed. For a list of correct driver and firmware versions, contact the service provider.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2164
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0202
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The configuration file (Path: arg1) that contains firmware and driver information for arg2 is not updated or is incorrectly formatted to complete the comparison.
- Arguments
- arg1 = file path
- arg2 = controller name
- Detailed Description
- Storage Services is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers because a configuration file is not readable, corrupted, or has missing data.
- Recommended Response Action
- Reinstall Server Administrator and Storage Services.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2166
- OMSA Trap ID
- 75300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0203
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The current operating system kernel version and the non-RAID SCSI driver version are older than the minimum required versions.
- Detailed Description
- The version of the operating system kernel and the driver do not meet the minimum requirements. Storage Services may not be able to display or perform storage management functions until the system meets the minimum requirements.
- Recommended Response Action
- See the Readme file on the installation media for operating system kernel and driver version requirements. Update the system to meet the minimum requirements and then reinstall Storage Services.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2167
- OMSA Trap ID
- 10300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0204
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The non-RAID SCSI driver version is older than the minimum required version.
- Detailed Description
- The driver version does not meet the minimum requirements and Storage Services cannot perform the required operations until the minimum requirements are met.
- Recommended Response Action
- See the Readme file for the driver requirements and update the system to meet the minimum requirements and reinstall Storage Services.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2168
- OMSA Trap ID
- 10300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0205
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Global rescan initiated for all storage components in the system.
- Detailed Description
- A rescan of all storage components in the system is initiated.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2261
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0206
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Smart thermal shutdown feature is enabled.
- Detailed Description
- The storage shutdown feature based on high ambient temperature (smart thermal shutdown) is enabled.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2262
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0207
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Smart thermal shutdown feature is disabled.
- Detailed Description
- The storage shutdown feature based on high ambient temperature (smart thermal shutdown) is disabled.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2263
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0208
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Protection policy has changed.
- Detailed Description
- A new protection policy is created or an existing protection policy is modified.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2287
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0209
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to monitor or manage SAS components because the initialization sequence of the devices did not complete.
- Detailed Description
- The initialization sequence of SAS components did not complete during system startup.
- Recommended Response Action
- Do the following: 1) Make sure that the supported versions of the SAS drivers and firmware are installed. 2) Reboot the system. If problem persists, reinstall Server Administrator and Storage Services on the managed node to make sure all the required components are installed.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- OMSA Event ID
- 2314
- OMSA Trap ID
- 10400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The controller key is not present.
- Detailed Description
- Operation cannot be completed because a controller key is not present.
- Recommended Response Action
- Set an appropriate controller key and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0210
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- SCSI sense data (arg1) received from arg2.
- Arguments
- arg1 = sense info
- arg2 = device name
- Detailed Description
- A SCSI device may have experienced an error that generated sense data after the device recovery.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2095
- OMSA Trap ID
- 75100;85100;90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0211
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 has returned to normal state.
- Arguments
- arg1 = device name
- Detailed Description
- The device identified in the message that was previously in an error state has returned to a normal state. For example, if an enclosure became too hot and subsequently cooled down, or if a degraded virtual disk returns to normal state.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2121
- OMSA Trap ID
- 75200;80200;85200;90200;95200;100200;105200;110200;115200;120100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR0212
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 has failed.
- Arguments
- arg1 = device name
- Detailed Description
- The device (physical disk or an enclosure) identified in the message has failed. The device (physical disk or an enclosure) failure was detected while performing a rescan. However, physical disk failures are also detected during a check consistency operation.
- Recommended Response Action
- Replace the identified device. A failed device is indicated with a red color "X" status icon. Perform a rescan after replacing the failed device.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- OMSA Event ID
- 2048
- OMSA Trap ID
- 75400;80400;85400;90400;95400;100400;105400;110400;115400;120400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The controller is not security capable.
- Detailed Description
- The operation cannot be completed because controller is not security capable.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR023
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform configuration operations because a configuration job for the device already exists.
- Detailed Description
- Unable to perform configuration operations because a configuration job for the device already exists.
- Recommended Response Action
- Wait for the current job for the device to complete or cancel the current job before attempting more configuration operations on the device.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create a configuration job because a configuration job for the device already exists.
- Detailed Description
- Configuration changes for the specified device are already scheduled.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to delete any pending configuration because the configuration job is already scheduled.
- Detailed Description
- The pending configuration cannot be deleted because the configuration job is already scheduled.
- Recommended Response Action
- Delete the current configuration job for the device to stop pending configuration changes.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A configuration job was not created because there are no pending configuration changes.
- Detailed Description
- A configuration job was not created because there are no pending configuration changes.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR027
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Virtual Disk name is not supported.
- Detailed Description
- Setting the Virtual disk name is not a valid operation on the specified controller.
- Recommended Response Action
- Do not specify the virtual disk name and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR028
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Virtual disk not found.
- Detailed Description
- The requested operation cannot be completed because the specified virtual disk is not found.
- Recommended Response Action
- Provide a valid virtual disk FQDD (Fully Qualified Device Descriptor) and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR029
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Physical disk not found.
- Detailed Description
- The requested operation cannot be completed because the specified physical disk is not found.
- Recommended Response Action
- Provide a valid physical disk FQDD (Fully Qualified Device Descriptor) and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller not found.
- Detailed Description
- The requested operation cannot be completed because the specified controller is not found.
- Recommended Response Action
- Provide a valid controller FQDD (Fully Qualified Device Descriptor) and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Lifecycle Controller is not enabled.
- Detailed Description
- For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G and above generations: Lifecycle Controller must be enabled to perform the requested operation. Lifecycle Controller has been disabled by pressing F2 Setup, selecting iDRAC Configuration, and selecting Lifecycle Controller Settings on boot up or through a remote operation.
- Recommended Response Action
- For 11G systems: Use the iDRAC configuration utility to enable the System Services by pressing on the CTRL+E option on boot up at the targeted system. For 12G and above generations: Use F2 Setup, select iDRAC Configuration, and select Lifecycle Controller Settings, to enable the Lifecycle Controller on boot up of the targeted system.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Lifecycle Controller is currently in use.
- Detailed Description
- Lifecycle Controller is unable to gain access to internal storage because it is in use by another application or operation.
- Recommended Response Action
- Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Controller Configuration utility 2) Not waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid parameter value for Start/Until Time.
- Detailed Description
- The requested operation cannot be completed because an invalid value is specified for Start/Until Time.
- Recommended Response Action
- Enter a valid Start/Until Time and retry the operation. For more information about the Start/Until Time, see the RAID Profile specification.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid parameter value for RebootJobType.
- Detailed Description
- The requested operation cannot be completed because an invalid value is specified for RebootJobType.
- Recommended Response Action
- Enter a valid RebootJobType value and retry the operation. For more information about the RebootJobType parameter, see the RAID Profile specification.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform operation because either the number of storage objects specified is insufficient or the storage objects are not in a required state to perform this operation.
- Detailed Description
- Unable to perform operation because either the number of storage objects specified is insufficient or the storage objects are not in a required state to perform this operation.
- Recommended Response Action
- Check the number and state of storage objects and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform operation because there are one or more Secure Virtual Disks associated with the controller.
- Detailed Description
- Unable to perform operation because there are one or more Secure Virtual Disks associated with the controller.
- Recommended Response Action
- Delete the Secure Virtual Disk(s) associated with this controller and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Missing required parameter arg1.
- Arguments
- arg1 = parameter name
- Detailed Description
- Unable to complete the requested operation because one or more input parameters identified in the message are not specified.
- Recommended Response Action
- Enter all the required parameters and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR038
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid parameter value for arg1.
- Arguments
- arg1 = parameter name
- Detailed Description
- Unable to complete the requested operation because one or more input parameters identified in the message are not valid.
- Recommended Response Action
- Specify a valid value for identified parameter.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR039
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Mismatch in AttributeName and AttributeValue count.
- Detailed Description
- Unable to complete the requested operation because of a mismatch in the number of AttributeName and AttributeValue values specified.
- Recommended Response Action
- Specify a valid number of AttributeName and AttributeValue pair values and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR040
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid AttributeName arg1.
- Arguments
- arg1 = attribute name
- Detailed Description
- Unable to complete the requested operation because an invalid AttributeName value is specified.
- Recommended Response Action
- Specify a valid AttributeName value for the attribute identified in the message and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR041
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid value for AttributeName arg1
- Arguments
- arg1 = attribute name
- Detailed Description
- Unable to complete the requested operation because an invalid value for the attribute identified in the message is specified.
- Recommended Response Action
- Specify a valid value for the attribute identified in the message and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR042
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unsupported value for AttributeName arg1
- Arguments
- arg1 = attribute name
- Detailed Description
- Unable to complete the requested operation because the attribute value specified is not supported in the current configuration.
- Recommended Response Action
- Specify a value for the attribute identified in the message by using one of the possible values currently available for that attribute.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR043
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more selected physical disk drives are part of virtual disk that is not Secondary RAID Level 0.
- Detailed Description
- One or more physical disk drives selected for the operation are part of a virtual disk that is not Secondary RAID Level 0.
- Recommended Response Action
- This operation is not supported unless the previous virtual disk on the selected physical disk drives are deleted first. To perform the operation, delete any virtual disk on the selected physical disks drives and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR044
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- All physical disks specified are not part of the same disk group.
- Detailed Description
- One or more physical disks specified to create virtual disk (VD) is not valid because it is not part of the same disk group.
- Recommended Response Action
- Enumerate existing virtual disks to find the physical disks of the same disk group. Specify physical disks that are of the same disk group and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR045
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- StartingLBA and Size parameters are required to create a virtual disk.
- Detailed Description
- The specified physical disks have fragmented disk space, therefore StartingLBA and Size parameters are required to be specified in order to create a virtual disk.
- Recommended Response Action
- Specify StartingLBA and Size parameters and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR046
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The specified StartingLBA and Size values combination result in an overlapping virtual disk.
- Detailed Description
- Unable to complete the create virtual disk operation because the StartingLBA and Size value combination results in an overlapping virtual disk.
- Recommended Response Action
- Refer to the users guide to provide the correct StartingLBA and Size combination values.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR047
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the value of attribute arg1 because it is ReadOnly.
- Arguments
- arg1 = attribute
- Detailed Description
- Unable to change the value of the attribute identified in the message because it is ReadOnly.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR048
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller is not Dell Key Management capable.
- Detailed Description
- Either the controller or the firmware on the controller does not support the Dell Key Management feature.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR049
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The controller is in Local Key Management mode.
- Detailed Description
- The requested operation cannot be completed because the operation is not supported in the Local Key Management mode.
- Recommended Response Action
- Make sure that the Local Key Management mode is disabled on the controller and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR050
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller is in Dell Key Management mode.
- Detailed Description
- The controller is in Local Key Management mode.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0501
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to configure RAID.
- Detailed Description
- Unable to create a virtual disk due to unknown reasons.
- Recommended Response Action
- Do one of the following and retry the operation: 1) Exit the RAID Configuration wizard. 2) Update the RAID controller firmware to the latest version. 3) Reboot the system and press the <F10> key to re-enter Lifecycle Controller, and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0502
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to launch RAID Configuration wizard.
- Detailed Description
- No RAID controller is installed on the system.
- Recommended Response Action
- Install the RAID controller and do the following: 1) Reboot the system. 2) Press the <F10> key to re-enter Lifecycle Controller. 3) Retry RAID configuration.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0503
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Successfully erased RAID configuration.
- Detailed Description
- Existing RAID configuration was successfully erased.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0504
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Successfully completed RAID operation.
- Detailed Description
- The RAID operation was successful.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0505
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to delete virtual disks.
- Detailed Description
- Unable to delete the existing virtual disks for unknown reasons.
- Recommended Response Action
- Exit the RAID Configuration wizard and retry the operation. If the problem persists do the following: 1) Reboot the system. 2) Press the <F10> key to re-enter Lifecycle Controller. 3) Retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0506
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create virtual disk.
- Detailed Description
- The physical disk is unreadable or the RAID controller is not responding.
- Recommended Response Action
- Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, replace the physical disk or update the RAID controller firmware to the latest version, and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0507
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Insufficient physical disk space on selected RAID controller.
- Detailed Description
- The RAID controller does not have sufficient number of initialized physical disks or adequate disk space to create the requested virtual disk.
- Recommended Response Action
- Connect additional physical disks to the RAID controller, initialize the physical disks, and retry the operation. To initialize the physical disks, reboot the system and select Option ROM during system startup.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0508
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No supported controllers present for RAID configuration.
- Detailed Description
- Unable to configure RAID as the supported RAID controller is not present.
- Recommended Response Action
- Install a supported RAID controller and the required number of physical disks for the RAID configuration, and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0509
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No RAID levels are supported.
- Detailed Description
- The controller does not have the minimum number of initialized disks to create a virtual disk.
- Recommended Response Action
- Connect required number of initialized physical disks to the RAID controller and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR051
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- StartingLBA and Size value combination is greater than allowed by the physical disk size.
- Detailed Description
- The requested operation cannot be completed because the specified StartingLBA and Size value combination is greater than allowed by the physical disk size.
- Recommended Response Action
- Specify the Size value only and allow the instrumentation to calculate the StartingLBA value then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0510
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Encryption configuration failed.
- Detailed Description
- Unable to apply the RAID controller encryption because RAID controller is not responding.
- Recommended Response Action
- Retry the operation. If the problem persists, reboot the system or update the RAID controller firmware to the latest version and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0511
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the encryption key.
- Detailed Description
- Unable to change the encryption key due to an internal error.
- Recommended Response Action
- Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0512
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to apply the encryption key.
- Detailed Description
- Unable to apply the encryption key due to an internal error.
- Recommended Response Action
- Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0513
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to encrypt virtual disks.
- Detailed Description
- Unable to encrypt unsecure virtual disks due to an internal error.
- Recommended Response Action
- Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0514
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to initialize the selected physical disk drive(s).
- Detailed Description
- The physical disk drive(s) cannot be initialized because the selected RAID controller does not support this operation while in non-RAID mode.
- Recommended Response Action
- Do one of the following: 1) Select a controller that is in RAID mode and retry the operation. 2) Update the controller firmware to the latest version and retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR052
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create virtual disk, maximum number of created virtual disks per controller or diskgroup has been reached.
- Detailed Description
- Virtual disks cannot be created because the maximum number of logical drives per controller or diskgroup is reached.
- Recommended Response Action
- Refer to the Users Guide of the specific controller available at the support site for information on the number of supported virtual disks allowed.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR053
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The controller key is not present. The key must be retrieved from the Dell Key Management Server.
- Detailed Description
- The system could not obtain a controller key from the Dell Key Management Server.
- Recommended Response Action
- For more information about obtaining a key, see Dell Key Manager or Lifecycle Controller Remote Services Guide available at dell.com/support/manuals.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR054
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller is not CacheCade capable.
- Detailed Description
- The controller or the firmware on the controller does not support the CacheCade feature.
- Recommended Response Action
- Refer to the specific controller users guide for more information.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR055
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- BIOS does not support Dell Key Manager capabilities.
- Detailed Description
- The BIOS on the server is not Dell Key Management capable.
- Recommended Response Action
- For more information about key management capabilities, see Dell Key Manager or Lifecycle Controller Remote Services Guide available at dell.com/support/manuals.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR056
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Physical disk is not security capable.
- Detailed Description
- Unable to complete the requested operation because the specified physical disk does not support data encryption.
- Recommended Response Action
- Specify a physical disk that is security capable and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR057
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The specified RAID controller is not currently available for configuration.
- Detailed Description
- The instrumentation for the specified RAID controller is not in state where the requested operation can be performed because system inventory collection (the CSIOR feature) has not been executed.
- Recommended Response Action
- Enable the CSIOR (Collect System Inventory On Restart) feature and restart the server to cause CSIOR execution. Make sure the Remote Services status is Ready and retry the operation. To get the Remote Services status, invoke the GetRSStatus method. For more information about this method, see Lifecycle Controller Remote Services Guide.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR058
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operation cannot be completed either because the operation is not supported on the target device, or the RAIDType of "MD Software RAID" does not allow the operation.
- Detailed Description
- Unable to complete the operation either because the operation is not supported on the target device, or the RAIDType of "MD Software RAID" does not allow the operation.
- Recommended Response Action
- Do the following and retry the operation: 1) Make sure that the target device supports the operation. 2) Make sure that if the RAIDType is set to "MD Software RAID" ensure that is the desired value. For more information, see the iDRAC Users Guide available on the support site.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR059
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The requested operation is not currently valid because there are no virtual disks on the controller.
- Detailed Description
- The requested operation cannot be completed because there are no virtual disks (VD) available on the specified controller.
- Recommended Response Action
- Create a virtual disk and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR060
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Configuration operations are not supported on the specified storage controller.
- Detailed Description
- The requested operation is not supported on the specified storage controller.
- Recommended Response Action
- For more information about supported operations, see the documentation specific for the targeted storage controller.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR061
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Initializing virtual disk is not supported on the RAID controller.
- Detailed Description
- The initializing virtual disk operation is not supported on the target device.
- Recommended Response Action
- For more information about supported operations, see the documentation specific for the targeted RAID controller or the Lifecycle Controller Remote Services Quick Start Guide.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR062
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more physical disks specified are full and cannot be used to create additional virtual disks.
- Detailed Description
- One or more physical disks specified are full and cannot be used to create additional virtual disks.
- Recommended Response Action
- Make sure all physical disks specified to create a virtual disk have the required amount of free space and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR063
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign the specified virtual disk to multiple Virtual Adapters in single assignment mode.
- Detailed Description
- In order to prevent data loss, the system has prevented the assignment of a Virtual Disk to multiple Virtual Adapters because the clustered assignment mode is not enabled.
- Recommended Response Action
- Enable clustered assignment mode or unassign the virtual disk from the Virtual Adapter it is currently assigned to and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR064
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more physical disks specified for creating a virtual disk do not have the same block size.
- Detailed Description
- Unable to create the requested virtual disk because the physical disks specified did not have the same block size.
- Recommended Response Action
- Verify that the physical disks selected for creating the virtual disk have the same block size and retry the operation. The block size can be determined by reviewing the physical disk inventory and checking the BlockSize property for each physical disk.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR065
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- One or more physical disks specified for creating a virtual disk are not T10 Protection Information capable.
- Detailed Description
- Unable to create the requested virtual disk because one or more specified physical disk(s) is not T10 Protection Information capable.
- Recommended Response Action
- Verify that the physical disks selected for creating a virtual disk are T10 Protection Information capable, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR066
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller is not T10 Protection Information capable.
- Detailed Description
- The requested operation did not succeed because the selected RAID controller is not T10 Protection Information capable.
- Recommended Response Action
- Verify that the RAID controller selected for the operation is T10 Protection Information capable, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR067
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller does not support uneven span RAID10 virtual disks.
- Detailed Description
- The operation did not succeed since the selected controller does not support creating uneven span RAID10 virtual disks.
- Recommended Response Action
- The selected controller is not capable of creating an uneven span RAID10 virtual disk. Specify the proper span length and span depth combination for creating RAID10 virtual disk on the selected controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR068
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the requested RAID configuration because the Lifecycle Controller version on the server does not have the necessary capabilities.
- Detailed Description
- The requested RAID configuration operation did not succeed because the Lifecycle Controller version on the target server does not have the necessary capabilities.
- Recommended Response Action
- Check the Lifecycle Controller version on the target server and update it with the latest version available.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR069
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the arg1 method, because the number of elements entered for VDPropNameArray and VDPropValueArray is unequal.
- Arguments
- arg1 = method name
- Detailed Description
- The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArray and VDPropValueArray is not equal.
- Recommended Response Action
- Enter equal number of elements (pair value), and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR070
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the WS-MAN method arg1, because an invalid parameter arg2 is entered.
- Arguments
- arg1 = method name
- arg2 = parameter name
- Detailed Description
- The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArray and VDPropValueArray is not equal.
- Recommended Response Action
- Enter a valid parameter, and then retry the operation. For more information about a valid parameter, refer to the SimpleRAIDProfile document available at DellTechCenter http://en.community.dell.com/techcenter/extras/m/white_papers/20263535.aspx.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0701
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Storage objects are unavailable in the current system configuration.
- Detailed Description
- There are no RAID controllers, physical disks or virtual disks discovered by instrumentation that can be configured.
- Recommended Response Action
- Storage objects are unavailable in the current system configuration. Make sure that the storage devices are installed in the system, and then retry the operation after the Collect System Inventory On Restart (CSIOR) feature has updated the system inventory.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR0702
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The value entered for the arg1 option is invalid.
- Arguments
- arg1 = option name
- Detailed Description
- The value entered for the option name identified in the message is invalid.
- Recommended Response Action
- Enter a valid data and retry the operation. For more information about the correct data, refer to the Online RACADM Help information by running the "racadm help storage" command at the Command Line Interface (CLI).
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR071
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Span Count is not valid for creating a RAID 10. Valid Span counts are arg1.
- Arguments
- arg1 = valid span counts
- Detailed Description
- The configuration operation could not be performed because the specified span count is not valid.
- Recommended Response Action
- Enter a valid span count, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR072
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- iDRAC Service Module (ISM) is either not present or not running on the server OS.
- Detailed Description
- The configuration operation could not be performed because it requires iDRAC Service Module (ISM) service to be present and running in the server Operating System.
- Recommended Response Action
- Make sure the iDRAC Service Module (ISM) service is running on the server Operating System and then retry the operation. Refer to the iDRAC User Guide for installing and starting ISM.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR073
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The iDRAC Service Module version present on the server OS does not support the requested PCIe SSD (NVMe) device operation.
- Detailed Description
- The iDRAC Service Module version present on the server OS does not support the requested PCIe SSD (NVMe) device operation.
- Recommended Response Action
- Update the Dell iDRAC Service Module (ISM) to the version that supports the requested operation on the PCIe SSD (NVMe) device.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR074
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The requested RAID configuration operation is not allowed because the controller is currently in HBA mode.
- Detailed Description
- The requested RAID configuration operation will not be allowed because the RAID controller is currently in HBA mode.
- Recommended Response Action
- In order to perform a RAID configuration operation, change the controller mode to RAID and retry the operation. For switching to RAID mode using the F2 System Setup utility, go to Device Settings > "RAID Controller "> Controller Management > Advanced Controller Management > Switch to RAID mode.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR075
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operation cannot be performed because the enclosure configuration mode (Split or Unified) change request is pending.
- Detailed Description
- The requested operation could not be completed because there is an operation pending to change the enclosure configuration mode (Split or Unified). This operation is exclusive because it involves changing the RAID backplane topology.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending enclosure mode change request operation, allow the job to complete, restart the server, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR076
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Enclosure configuration mode (Split/Unified) cannot be changed because there are already pending operations.
- Detailed Description
- The requested operation could not be completed because at least one other pending operation was found on the RAID controller. This operation needs exclusivity because it involves changing RAID backplane topology.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending operations, allow the job to complete, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR077
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change Patrol Read State since Patrol Read Mode is not set to Manual.
- Detailed Description
- A Patrol Read State change operation cannot be performed if the Patrol Read Mode is not set to Manual.
- Recommended Response Action
- Change the Patrol Read Mode to Manual before performing a Patrol Read State change operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR078
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The requested operation requires a reboot type that does not match the reboot type required for pending operations.
- Detailed Description
- The requested operation cannot be performed because it involves server reboot type which is different than the reboot type of pending operations. Combining operations with different reboot types for the same RAID controller is not supported by iDRAC.
- Recommended Response Action
- Cancel any pending operations on the RAID controller and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR079
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The device does not support this operation or is in a state that does not allow this operation.
- Detailed Description
- The requested operation cannot be performed because it is either not supported by the device or the device was not in the right state to perform the operation.
- Recommended Response Action
- Make sure the device supports the requested operation. If the operation is supported, then make sure the server is turned on and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR081
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The job could not be created because the reboot type selected for the job creation and the reboot type required for pending operations do not match.
- Detailed Description
- The job could not be created because the reboot type selected for the job creation and the reboot type required for pending operations do not match.
- Recommended Response Action
- Change the reboot type for job creation and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR082
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operation cannot be stopped or cancelled because the operation is not currently running.
- Detailed Description
- The operation cannot be stopped or canceled because the operation is not currently running.
- Recommended Response Action
- Make sure the operation is running before attempting to cancel or stop the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR083
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Physical Disk(s) specified are too small to create a Virtual Disk of the requested size.
- Detailed Description
- The Physical Disk(s) specified are too small to create a Virtual Disk of the requested size.
- Recommended Response Action
- Specify Physical Disk FQDD IDs of physical disk drive(s) that have a larger disk space, and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR084
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create the job because another job is currently running
- Detailed Description
- The requested job cannot be run because another job is currently running. Two options for running jobs on multiple storage controllers are: 1) Run the jobs on each controller individually. Wait for each job to complete before starting the configuration and job creation on the next controller. 2) Schedule multiple jobs to run at a later time using the scheduling options.
- Recommended Response Action
- Make sure that the currently running job is completed, and then retry the operation. If necessary, recreate the configuration and the job. For information about running jobs on multiple storage controllers, see the iDRAC Online Help or iDRAC Users Guide.
- Category
- Configuration (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR085
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign the virtual disk (VD) to a virtual adapter (VA) because the VD is already assigned to a VA.
- Detailed Description
- The virtual disk (VD) specified in the operation cannot be assigned to virtual adapter (VA) because the VD is already assigned to a VA.
- Recommended Response Action
- Make sure that the VD specified in the operation is not assigned to a VA, and then retry the operation. To check if a VD is already assigned, run the WS-Man command: enumerate DCIM_VirtualDiskView class.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR086
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the high availability (HA) mode of RAID storage because the servers are turned on.
- Detailed Description
- The high availability (HA) mode of RAID storage cannot be changed because the servers are turned on.
- Recommended Response Action
- Turn off all the servers in the chassis and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR087
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the configuration operation because System Lockdown mode is enabled.
- Detailed Description
- The configuration operation cannot be started because the System Lockdown mode is enabled.
- Recommended Response Action
- Make sure that the Lockdown.1#SystemLockdown attribute is set to Disabled and then retry the operation. For information about the Lockdown mode, see the relevant iDRAC Users Guide available on the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR088
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the enclosure FQDD (Fully Qualified Device Descriptor) specified in the input is not valid.
- Detailed Description
- The requested operation cannot be completed because the enclosure FQDD (Fully Qualified Device Descriptor) specified in the input is not valid.
- Recommended Response Action
- Enter a valid enclosure FQDD (Fully Qualified Device Descriptor) and retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR089
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage configuration operation is successfully completed and the change is in pending state.
- Detailed Description
- The storage configuration operation is successfully completed and the change is in pending state.
- Recommended Response Action
- To apply the configuration operation immediately, create a configuration job using the --realtime option. To create the necessary real-time job, run the jobqueue command. For more information about jobqueue command, run the racadm help jobqueue command.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR090
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create a virtual disk because an invalid combination of span count or number of disks was entered for the RAID level selected.
- Detailed Description
- Unable to create a virtual disk because an invalid combination of span count or disks passed was entered for the RAID level selected.
- Recommended Response Action
- Enter a span count value (-sc option) or number of disks (-pdkey option) that is appropriate for the RAID level selected. See the PERC Controller Users Guide for valid span count and number of disks required for a raid level. Retry the operation by running the RACADM storage createvd command with the appropriate options.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR092
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the configuration operation on the controller because foreign configuration import operation is in progress.
- Detailed Description
- The requested configuration operation cannot be run because a foreign configuration import operation on the controller is already in progress.
- Recommended Response Action
- Wait for the import process to complete before running any configuration operation.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR093
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the configuration operation because the controller is not available for the import process.
- Detailed Description
- The configuration operation cannot be performed because the controller is not available for import process.
- Recommended Response Action
- Make sure an operation is not pending on the controller. If an operation is pending, wait for the operation to complete or cancel the pending operation and then retry the operation. Refer to the storage controller documentation for compatibility information.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR094
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage configuration operation is successfully completed and the change is in pending state.
- Detailed Description
- The storage configuration operation is successfully completed and the change is in pending state.
- Recommended Response Action
- To apply the configuration operation immediately, create a configuration job using the --realTime option. To apply the configuration after restarting the server, create a configuration job using the -r option. To create the necessary real-time and restart jobs, run the jobqueue command. For more information about jobqueue command, run the racadm help jobqueue command.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR095
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Storage operation is successfully completed.
- Detailed Description
- Storage operation is successfully completed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR096
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create a virtual disk because the disk space size value entered for the virtual disk is less than the lower limit value (100 MB).
- Detailed Description
- A virtual disk cannot be created because the disk space size value entered for the virtual disk is less than the lower limit value (100 MB).
- Recommended Response Action
- Enter a value (the -size option) equal or higher than 100 MB, and then retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR097
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the memory size of the physical disk drive is less than the available or entered virtual disk size.
- Detailed Description
- A virtual disk cannot be created because the memory size of the physical disk drive is less than available or entered virtual disk size.
- Recommended Response Action
- Enter the FQDD of a physical disk drive that has a larger disk space, and then retry the operation. To view a list of physical disk drives and associated disk space, run the RACADM command "racadm storage get pdisks -o -p size". To view a list of virtual disks and associated size, run the RACADM command "racadm storage get vdisks -o -p size".
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR099
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to find the FQDD arg1 because an invalid FQDD is entered or an operation is pending on the specified FQDD.
- Arguments
- arg1 = component FQDD
- Detailed Description
- The FQDD cannot be found because an invalid FQDD is entered or an operation is pending on the FQDD identified in the message.
- Recommended Response Action
- Do the following and then retry the operation: 1) Make sure the FQDD entered is valid. 2) Make sure an operation is not pending on the FQDD identified in the message. For more information refer to the RACADM Command Line Reference Guide.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR1
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A device arg1 is in an unknown state.
- Arguments
- arg1 = device name
- Detailed Description
- The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the driver or firmware.
- Recommended Response Action
- See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system. Verify that the controller has a supported version of the driver and firmware. Rebooting the system may resolve this problem.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- OMSA Event ID
- 2265
- OMSA Trap ID
- 75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR10
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Access to shared storage will not be available, because the RAID controller is unable to turn on.
- Detailed Description
- The RAID controller was detected, however it is unable to turn on. Access to shared storage will not be available.
- Recommended Response Action
- Update the Chassis Infrastructure firmware.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Trap/EventID
- 4177
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
STOR100
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because no drives were found that were locked by using a matching foreign key identifier.
- Detailed Description
- The operation cannot be completed because no drives were found that were locked by using a matching foreign key identifier.
- Recommended Response Action
- Check the security status of drives in the Physical Disks Properties section and retry the operation. To check by using graphical user interface (GUI), click Controller > Properties > Security Status and Encryption Key Identifier. To check by using RACADM, run "racadm raid get pdisks -o -p securityStatus,ForeignKeyIdentifier" at the command line interface (CLI).
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the keyID entered does not match the key identifier (keyID) of the peer controller.
- Detailed Description
- The operation cannot be completed because the keyID entered does not match the key identifier (keyID) of the peer controller.
- Recommended Response Action
- Make sure that the key identifier of both the controllers is same and retry the operation. To view the keyID of the peer controller, enter "racadm raid get controllers -o -p keyid" at the command line interface (CLI).
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the operation because the hard disk drives (HDDs) have the RAID controller in mixed RAID mode.
- Detailed Description
- The operation cannot be performed because the HDDs have the RAID controller in mixed RAID mode.
- Recommended Response Action
- Do the following to separate the mixed RAID mode and retry the operation. 1) Group the hard disk drives (HDDs) into to Windows and Linux metadata categories by observing the RAIDType property on the Physical Disk page of iDRAC graphical user interface (GUI). 2) Convert a group of selected HDDs to non-RAID mode by running the ConvertToNonRAID method or RACADM command, or by setting the RAIDPDState to NonRAID in the Server Configuration Profile.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR103
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to convert the physical disk drive to Ready status because either the input value is not supported or the controllers current RAID mode does not allow the input value.
- Detailed Description
- The physical disk drive cannot be converted to Ready status because either the input value is not supported or the controllers current RAID mode does not allow the input value. The RAIDMode may not match the RAIDType or the SoftwareRAIDMode requested.
- Recommended Response Action
- Make sure that the input value is correct and retry the operation. If RAIDMode has a value then the requested RAIDType or SoftwareRAIDMode value must match.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the operation because the operation is not supported on the NVMe RAID drives.
- Detailed Description
- The operation cannot be started because the operation is not supported on the NVMe RAID drives. Either the drive is behind hardware RAID controller or the RAIDMode may not match the RAIDType or the SoftwareRAIDMode requested.
- Recommended Response Action
- Set the NVMeMode attribute of BIOS to NonRAID and retry the operation. To set the NonRAID mode, see the staged objects example of setting Single-Object in the SET command section of the iDRAC RACADM CLI Reference guide available on the support site. To verify the setting by using iDRAC Graphical User Interface (GUI), click Configuration > BIOS Settings > NVMe Settings. No response action is required if the NVMe drives are behind hardware RAID controller, because this operation is not supported.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR11
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The currently detected hardware configuration is High Availability Ready. However, the current software solution does not yet support high availability.
- Detailed Description
- The current hardware configuration is setup correctly for High Availability. However, the current firmware does not provide this functionality and one of the cards will be kept in a powered down state until High Availability capable firmware is installed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
STOR112
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the Controller Rekey operation because the iDRAC Secure Enterprise Key ID and Controller Key ID are the same.
- Detailed Description
- The Controller Rekey operation cannot be performed because the iDRAC Secure Enterprise Key ID and Controller Key ID are the same.
- Recommended Response Action
- Use the Rekey operation in iDRAC and retry the operation. For more information, see the iDRAC Users Guide available on the support site.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR12
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis is operating with a disabled RAID controller.
- Detailed Description
- One or more RAID controllers is disabled. This prevents Fault Tolerant mode from operating.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD, Chassis Event Proxy*
STOR13
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to set the operation mode of the newly inserted storage sled in slot arg1 to Split Single or Split Dual Host, because the storage sled has only one PERC controller.
- Arguments
- arg1 = slot number
- Detailed Description
- The operation mode of the newly inserted storage sled in the slot identified in the message cannot be set because the storage sled has only one PERC controller. The operation mode will only be Join after part replacement.
- Recommended Response Action
- Make sure that the newly inserted storage sled has the same number of PERC controllers as the previous storage sled so that the new sled will have the same operation mode after part replacement.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, Chassis Event Proxy*
STOR14
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The peripheral sled in slot arg1 initialization is not complete.
- Arguments
- arg1 = slot number
- Detailed Description
- Peripheral sled initialization is not successful with following possible reasons: 1) FRU is not functioning. 2) Sled internal components are not responding. 3) Component power state is not good. 4) Hardware configuration errors.
- Recommended Response Action
- Do the following: 1) Check system log for further information about the issue, 2) Remove and re-insert the peripheral sled identified in the message or virtual reseat the sled, 3) Reset the CMC and wait for a few minutes for the CMC to finish restarting. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Trap/EventID
- 4177
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
STOR15
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage sled arg1 is improperly configured.
- Arguments
- arg1 = slot number
- Detailed Description
- The storage sled identified in the message was inserted in a location which does not support split dual host operation mode. The storage sled can functionally work in the current location with only primary PERC controller enabled.
- Recommended Response Action
- Do one of the following: 1) Change the operating mode of the storage sled identified in the message. 2) Insert the storage sled to a different slot.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
STOR16
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage sled arg1 configuration is normal.
- Arguments
- arg1 = slot number
- Detailed Description
- The configuration of the storage sled in the slot identified in the message is normal.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
STOR17
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The fault-tolerant pair of RAID controllers arg1 and arg2 can have issues in their PCIe fabric because both controllers are on the same PCIe fabric.
- Arguments
- arg1 = RAID controller 1
- arg2 = RAID controller 2
- Detailed Description
- The two RAID controllers are on the same PCIe Fabric. This means that an issue with a single PCIe switch or Mezzanine card could result in the loss of all storage functionality from this pair of controllers.
- Recommended Response Action
- Change the slot location of one of the RAID Controllers.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR18
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Shared Storage device is detected in slots other than Chassis Slots 5 and 6. This configuration is not currently supported.
- Detailed Description
- Utilizing Shared Storage add-in cards outside of slots 5 and 6 is not supported. The card will be allowed to turn on, however some functionality may be degraded.
- Recommended Response Action
- Remove the shared storage device from the unsupported slot and place it in slot 5 or 6.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR2
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- SCSI sense data arg1.
- Arguments
- arg1 = args
- Detailed Description
- A SCSI device experienced an error, but may have recovered.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR3
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CEM Storage Management has lost communication with the arg1.
- Arguments
- arg1 = Controller Name
- Detailed Description
- Storage Management has lost communication with a controller. This may occur if the connectivity between the controller and iDRAC is disrupted or any underlying hardware problems are encountered.
- Recommended Response Action
- Reboot the system or iDRAC. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Trap/EventID
- 4177
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR300
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the controller mode because there are already pending operations.
- Detailed Description
- The requested operation could not be completed because at least one other pending operation was found on the RAID controller. This operation needs exclusivity because it requires a server reboot for changes to apply.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending operations, allow the job to complete, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR301
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the operation because the controller mode change request is pending.
- Detailed Description
- The requested operation could not be completed because there is an operation pending to change the controller mode. This operation is exclusive because it requires a server reboot for changes to apply.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending controller mode change request operation, allow the job to complete, restart the server, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR302
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create the job because the Apply Operation Mode selected is not supported for this operation.
- Detailed Description
- The job could not be created because the Apply Operation Mode selected is not supported for this operation.
- Recommended Response Action
- Choose another appropriate Apply Operation mode and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR303
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change controller mode while foreign configuration is present on the controller.
- Detailed Description
- Controller mode cannot be changed as the controller has foreign configuration associated with it.
- Recommended Response Action
- Clear the foreign configuration and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR304
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change controller mode while Virtual Disks and/or Hotspares are present on the controller.
- Detailed Description
- Controller mode cannot be changed as the controller has virtual disk or hotspare associated with it.
- Recommended Response Action
- Delete the Virtual Disks and/or Hotspares and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR305
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because preserved cache is present on the controller.
- Detailed Description
- The operation cannot be completed because the preserved cache is present on the controller.
- Recommended Response Action
- To recover the data preserved in pinned cache do one of the following 1) Try importing foreign drives, if any. 2) Make sure that the enclosure containing the virtual drive is connected to the controller. 3) Install any drives that are reported as missed or failed. Pinned cache can be discarded if data saved in controller pinned cache is not required. For more information about managing preserve cache, refer to the PERC Users Guide available on the support site.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR306
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change controller mode while security key is assigned to the controller.
- Detailed Description
- Controller mode cannot be changed as the controller currently has the security key assigned.
- Recommended Response Action
- Delete the security key and retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR307
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the configuration operation because the export log operation is currently in progress.
- Detailed Description
- Unable to perform the configuration operation because the export log operation is currently in progress.
- Recommended Response Action
- Wait until the current export operation is complete, and then try the configuration operation again.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR308
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Controller is in HBA mode, RaidAction CreateAuto value is not supported.
- Detailed Description
- The Controller is in HBA mode, RaidAction CreateAuto value is not supported.
- Recommended Response Action
- In order to perform a RAID configuration operation, change the controller mode to RAID and retry the operation. For switching to RAID mode using the F2 System Setup utility, go to Device Settings > "RAID Controller "> Controller Management > Advanced Controller Management > Switch to RAID mode.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR309
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the command because multiple targets must not be entered as input in the Blink/Unblink Target method.
- Detailed Description
- The command cannot be run because multiple targets must not be entered as input in the Blink/Unblink Target method.
- Recommended Response Action
- Enter only one target FQDD (Fully Qualified Device Descriptor), and then retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR310
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to initialize the virtual disk because the RAID controller selected does not support the initialization mode.
- Detailed Description
- The virtual disk cannot be initialized because the RAID controller selected does not support the initialization mode.
- Recommended Response Action
- Make sure that the RAID controller selected for the operation supports the initialization mode, and they retry the operation. For more information about supported RAID controllers, see the specific documentation of RAID controller. Also, refer to the Dell Lifecycle Controller Remote Services Quick Start Guide available at the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR311
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A firmware update was applied to a drive that requires a DC power cycle (cold boot). If the drive is in an external enclosure, the updated firmware will only be activated after a DC power cycle of the enclosure.
- Detailed Description
- A drive firmware update was applied but requires a DC power cycle (cold boot) to activate. If the drive is internal to the system performing the update, no further action is required. If the drive is in an external enclosure, the enclosure must be turned off and then turned on in order for the updated drive firmware to activate.
- Recommended Response Action
- If the drive is internal to the system performing the update, no further action is required. If the drive is in an external enclosure, the enclosure must be turned off and then turned on in order for the updated drive firmware to activate. After turning off the external enclosure, wait for drives to spin down before turning the enclosure back on. The drive firmware will activate after the enclosure is turned back on.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR312
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware of the physical disk drive arg1 because an incorrect firmware image file is used.
- Arguments
- arg1 = drive number
- Detailed Description
- The firmware package being used to update the physical disk drive is not valid for the drive model identified in the message. The firmware package contains the drive component id in the list of supported drives, but the firmware image is not valid for the drive model identified in the message.
- Recommended Response Action
- Acquire the correct firmware image file for the drive model identified in the message, and then retry the operation. The correct image file can be found by using the drive model information and searching the support site for related firmware.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR313
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to run the command to reconfigure the Virtual Disk because the storage controller does not support reconfiguration operations.
- Detailed Description
- The storage controller does not support reconfiguration operations.
- Recommended Response Action
- Make sure of the following and retry the operation: 1) The latest version of Lifecycle Controller firmware is installed, 2) The storage controller supports reconfiguration process. For information about the supported storage controller versions, see the Lifecycle Controller Users Guide available on the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR314
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the reconfiguration operation on the virtual drive because a reconfiguration operation is either in pending state or already running.
- Detailed Description
- The reconfiguration operation cannot be started on the virtual drive because a reconfiguration operation is either in pending state or already running.
- Recommended Response Action
- Do one of the following: 1) Commit and run the pending reconfiguration operation and retry the operation. 2) Cancel the currently running or pending reconfiguration operation and retry the new reconfiguration operation.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR315
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the reconfiguration operation because the storage controller does not support reconfiguring a Virtual Disk that has more than one span.
- Detailed Description
- Certain RAID levels require a Virtual Disk to have more than one span. Reconfiguration operation on these Virtual Disks is not supported by the storage controller.
- Recommended Response Action
- Make sure that the Virtual Disk has a single span and retry the reconfiguration operation. For information about the RAID levels that have a single span, see the Lifecycle Controller Users Guide available at the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR316
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the reconfiguration operation because the storage controller does not support reconfiguration of a Virtual Disk that is part of a disk group that has multiple Virtual Disks.
- Detailed Description
- This occurs when a disk group is sliced to create multiple Virtual Disks. Reconfiguration of such sliced Virtual Disks is not supported.
- Recommended Response Action
- Make sure that the physical disk group has a single Virtual Disk and retry the reconfiguration operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR317
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the reconfiguration operation because the number of physical disks specified in the disk group is not as per the permitted range.
- Detailed Description
- A disk drive group has a limit on the minimum and maximum number of disk drives it can have on the basis of its Virtual Disk RAID level. When a reconfiguration operation is specified with additional physical disks the total number of physical disks should be in the disk groups permissible range.
- Recommended Response Action
- Enter the correct number of physical disks for the reconfiguration operation and retry the operation. The number of physical disks in a disk group must be within the disk groups permissible range. For information about the minimum and maximum possible physical disks in a disk group, see the Lifecycle Controller Users Guide available at the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR318
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the reconfiguration operation because the Virtual Disk size specified is invalid.
- Detailed Description
- Expansion of storage capacity of a Virtual Disk is limited by the disk space of its physical disks and the Virtual Disk RAID level. Based on these two values there is a maximum limit on the capacity expansion size of a Virtual Disk.
- Recommended Response Action
- Make sure that the Virtual Disk size specified for the reconfiguration operation is less than or equal to the maximum possible value. For information about the maximum possible value, see the Lifecycle Controller Users Guide available at the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR319
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the reconfiguration operation because a reconfiguration operation is already in progress for the Virtual Disk.
- Detailed Description
- The storage controller only allows one reconfiguration operation at a time on a Virtual Disk. A new reconfiguration operation cannot be requested until the currently executing reconfiguration operation is complete or is canceled.
- Recommended Response Action
- There are two possible actions. 1) Wait for the current reconfiguration operation to complete and then retry the new reconfiguration operation. 2) Cancel the current reconfiguration operation and then start the new reconfiguration operation.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR320
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to start the reconfiguration operation because the requested reconfiguration operation is invalid.
- Detailed Description
- The storage controller does not support online capacity expansion and RAID level migration of a Virtual Disk at the same time.
- Recommended Response Action
- There are two Reconfiguration operations possible on a Virtual Disk 1) Online Expansion of the storage capacity 2) RAID level migration . Only one of the above two operations can be specified in a Reconfiguration operation. Make sure that only one of the above two operation types is requested and retry the operation. Also make sure that if provided, the Virtual Disk size is at least 1% of the maximum expansion size possible. Also make sure that if provided, the new Virtual Disk RAID level is different from the existing raid level.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR321
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because one or more physical disk drives selected for the operation are currently used by another operation.
- Detailed Description
- The operation cannot be completed because one or more physical disk drives selected for the operation is currently used by another operation.
- Recommended Response Action
- Do one of the following and retry the operation: 1) Wait for the current operation to complete. 2) Select a drive that is free for the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR322
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the controller does not support replacement operations or its Copyback mode is not set to ON.
- Detailed Description
- The operation cannot be completed because the controller does not support Replacement operations or its Copyback mode is not set to ON.
- Recommended Response Action
- Do the following and retry the operation: 1) Make sure that the controller supports the Replacement operation. 2) The Copyback Mode is enabled. To set the Copyback Mode to ON on a 13th Generation PowerEdge server using iDRAC GUI, navigate to Storage > Controllers > Setup > Configure Controller Properties > Copyback Mode > Action > Set to ON and Apply. To set it to ON on a 14th Generation PowerEdge server using iDRAC GUI, navigate to Configuration > Storage Configuration > Select the Controller > Select the Copyback mode > Add to Pending Operations > Apply.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR323
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create RAID on the selected controller because the controller is in enhanced HBA mode.
- Detailed Description
- Unable to create RAID on the selected controller because the controller is in enhanced HBA mode.
- Recommended Response Action
- Retry the operation using other supported controllers.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR324
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the security key operations because the storage controller is already in the Security-Enabled Mode.
- Detailed Description
- The requested operation cannot be completed because the operation is not supported when the security mode of the storage controller is enabled.
- Recommended Response Action
- Make sure that the security mode is disabled on the storage controller and retry the operation. Run the following RACADM at the CLI: racadm storage security:<ControllerFQDD> -disable. To disable the security mode in the UI, do the following: 1) Click Storage > Controllers. 2) Select the specific storage controller. 3) Click Actions > Security > Disable Security > Apply Now or Later.
- Category
- Configuration (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR325
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the controller is waiting for a key from the Key Management Server.
- Detailed Description
- The requested operation cannot be completed because the controller is waiting for a key from the Key Management Server.
- Recommended Response Action
- Make sure that the controller "EncryptionMode" property shows "Supported with SEKM" and retry the operation. For more information about configuring the Secure Enterprise Key Manager on iDRAC see Lifecycle Controller Remote Services Guide available at dell.com/support/manuals.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR326
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because either the Controller or the Controller firmware version does not support the Secure Enterprise Key Manager feature.
- Detailed Description
- The operation cannot be completed because either the Controller or the Controller firmware version does not support the Secure Enterprise Key Manager feature.
- Recommended Response Action
- Make sure that the controller or the Controller firmware version supports the Secure Enterprise Key Manager feature. For more information about configuring the Secure Enterprise Key Manager on iDRAC see Lifecycle Controller Remote Services Guide available at dell.com/support/manuals.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR327
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the operation because the iDRAC is not configured to the Secure Enterprise Key Manager feature.
- Detailed Description
- The operation cannot be completed because the iDRAC is not configured to the Secure Enterprise Key Manager feature.
- Recommended Response Action
- Configure the iDRAC to the Secure Enterprise Key Manager feature, and then retry the operation. For information about configuring, see the Lifecycle Controller Remote Services Guide available on the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR328
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the controller unmap state because there are already pending operations.
- Detailed Description
- The requested operation could not be completed because at least one other pending operation was found on the RAID controller. This operation needs exclusivity because it requires a server reboot for changes to apply.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending operations, allow the job to complete, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR329
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the operation because the controller unmap state change request is pending.
- Detailed Description
- The requested operation could not be completed because there is an operation pending to change the controller unmap state. This operation is exclusive because it requires a server reboot for changes to apply.
- Recommended Response Action
- Do one of the following: 1) Create a job to complete the pending controller unmap state change request operation, allow the job to complete, restart the server, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
- Category
- Configuration (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR360
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Host LED Management of Non-RAID Disks feature is enabled.
- Detailed Description
- The Host LED Management of Non-RAID Disks feature is enabled. When enabled, you can manage LEDs of non-RAID drives by using the host application.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR361
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Host LED Management of Non-RAID Disks feature is disabled.
- Detailed Description
- The Host LED Management of Non-RAID Disks feature is disabled. When disabled, you cannot manage LEDs of non-RAID drives by using the host application.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR365
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The update of hardware Root of Trust (RoT) key is incomplete for the controller arg1, because the host device is not power cycled.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The update of hardware Root of Trust (RoT) key is incomplete for the controller identified in the message, because the host device is not power cycled.
- Recommended Response Action
- Power cycle the host device by running the following command at the Command Line Interface (CLI): "racadm serveraction powercycle".
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2476
- OMSA Trap ID
- 75100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR366
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The update of hardware Root of Trust (RoT) key is successfully completed for the controller arg1.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The update of hardware Root of Trust (RoT) key is successfully completed for the controller identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2477
- OMSA Trap ID
- 75100
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR367
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The firmware on the arg1 controller is successfully updated. However, to make the update effective, AC power cycle the host device.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The firmware on the controller identified in the message is successfully updated. However, to make the update effective, AC power cycle the host device.
- Recommended Response Action
- AC Power cycle the host device.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2478
- OMSA Trap ID
- 75300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR368
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware on the arg1 controller because the controller key change operation is pending.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The firmware on the controller identified in the message cannot be successfully updated because the controller key change operation is pending.
- Recommended Response Action
- To complete the controller key change operation, perform a power cycle by running the following RACADM command at the Command Line Interface (CLI): "racadm serveraction powercycle".
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2480
- OMSA Trap ID
- 75300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR369
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The soft Secure Boot mode is detected on the arg1 controller.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- PERC controller is in soft secure boot. This is not a factory config and will need to be replaced with a PERC controller which has hard secureboot enabled.
- Recommended Response Action
- Replace the PERC by using a PERC that has hard Secure Boot enabled. For information about replacing a PERC card, see the respective servers Installation and Service Manual available on the support site. Also, see the relevant QRL PowerEdge server micro videos.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- OMSA Event ID
- 2479
- OMSA Trap ID
- 75300
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR370
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update the firmware on the arg1 controller because one or more of the following reasons: a) Mismatch in the image file key. b) Unsuccessful authentication. c) Incorrect checksum value.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The firmware on the controller identified in the message cannot be updated because one or more of the following reasons: a) Mismatch in the image file key. b) Unsuccessful authentication. c) Incorrect checksum value.
- Recommended Response Action
- Download the latest controller firmware version from the support site, and then retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR371
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the physical drive arg1 because the drive selected is not unmap-capable for virtual drive configuration.
- Arguments
- arg1 = PD FQDD
- Detailed Description
- The physical drive identified in the message cannot be used because the drive selected is not unmap-capable for virtual drive configuration.
- Recommended Response Action
- Replace the physical drive with an unmap-capable drive, and then retry the operation.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR372
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create the unmap-enabled Virtual Drive (VD) arg1 because either the controller is not unmap-capable or the controllers unmap state is disabled.
- Arguments
- arg1 = Virtual Drive FQDD
- Detailed Description
- The unmap-enabled Virtual Drive (VD) identified in the message cannot be created because either the controller is not unmap-capable or the controllers unmap state is disabled.
- Recommended Response Action
- Make sure that the controller supports the unmap feature and the controller unmap state is enabled. To make sure, run the following RACADM command at the Command Line Interface (CLI): "racadm storage get controllers -o -p UnmapSupport,UnmapState".
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR373
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The dedicated hot-spare drive arg1 is no longer useful for the arg2 Virtual Drive (VD) because the unmap state of the VD is currently enabled.
- Arguments
- arg1 = physical drive FQDD
- arg2 = virtual Drive Friendly FQDD
- Detailed Description
- The dedicated hot-spare drive identified in the message is no longer useful for the Virtual Drive (VD) because the unmap state of the VD is currently enabled.
- Recommended Response Action
- Replace the existing dedicated hot-spare drive with an unmap-capable physical drive.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR374
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the non-Unmap-capable physical drive arg1 for the rebuilding operation.
- Arguments
- arg1 = physical drive friendly FQDD
- Detailed Description
- The non-Unmap-capable physical drive identified in the message cannot be used for rebuilding operation.
- Recommended Response Action
- Make sure the physical drive used for rebuild operation is "Unmap-capable for VD configuration", and then retry the operation. To check if the drive is unmap-capable, run the following command at the Command Line Interface (CLI): "racadm storage get pdisks -o -p UnmapCapabilityForVDConfig".
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR375
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the non-Unmap-capable physical drive arg1 for the copy-back operation.
- Arguments
- arg1 = physical drive friendly FQDD
- Detailed Description
- The non-Unmap-capable physical drive identified in the message cannot be used for copy-back operation.
- Recommended Response Action
- Make sure the physical drive used for copy-back operation is "Unmap-capable for VD configuration", and then retry the operation. To check if the drive is unmap-capable, run the following command at the Command Line Interface (CLI): "racadm storage get pdisks -o -p UnmapCapabilityForVDConfig".
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR376
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The unmap state of the arg1 Virtual Drive (VD) is updated.
- Arguments
- arg1 = virtual drive FQDD
- Detailed Description
- The unmap state of the Virtual Drive (VD) identified in the message is updated.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR377
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The UnmapState of the controller arg1 is changed by the user.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The Unmap state of the controller identified in the message is changed by the user.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR378
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the unmap state of the Virtual Drive (VD) arg1 because either the controller is not unmap-capable or the controllers unmap state is disabled.
- Arguments
- arg1 = Virtual Drive FQDD
- Detailed Description
- The unmap state of the Virtual Drive (VD) identified in the message cannot be changed because either the controller is not unmap-capable or the controllers unmap state is disabled.
- Recommended Response Action
- Make sure that the controller supports the unmap feature and the controller unmap state is enabled. To make sure, run the following RACADM command at the Command Line Interface (CLI): "racadm storage get controllers -o -p UnmapSupport,UnmapState".
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR379
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to change the unmap state of the Virtual Drive (VD) arg1 because the Virtual Drive is not unmap-capable.
- Arguments
- arg1 = Virtual Drive FQDD
- Detailed Description
- The unmap state of the Virtual Drive (VD) identified in the message cannot be changed because the Virtual Drive is not unmap capable.
- Recommended Response Action
- Make sure that the Virtual Drive is unmap capable. To make sure, run the following RACADM command at the Command Line Interface (CLI): "racadm storage get vdisks -o -p UnmapCapability".
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR390
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The drives on arg1 are configured because of the Auto Configure operation initiated by arg2.
- Arguments
- arg1 = Controller FQDD
- arg2 = user or firmware
- Detailed Description
- The drives on thecontroller, identified in the message, are configured because of the AutoConfigure operation initiated by anuser or controller firmwareasidentified in the message.
- Recommended Response Action
- No response action required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR391
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Auto Configuration Behavior feature on the arg1 is changed to arg2.
- Arguments
- arg1 = PERC FQDD
- arg2 = AutoConfigureBehavior Setting
- Detailed Description
- The Auto Configuration Behavior feature on the controller identified in the message is changed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR392
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Auto Configuration Parameters on the arg1 are changed.
- Arguments
- arg1 = PERC FQDD
- Detailed Description
- The Auto Configuration Parameters on the controller identified in the message are changed.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR393
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Auto-configure stacking is not allowed.
- Detailed Description
- Operation cannot be completed because auto-configure does not allow stacking.
- Recommended Response Action
- Cancel current pending operations and try again.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR394
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to discover the physical drive installed on the enclosure arg1, slot arg2, arg3, because of incompatibility issues.
- Arguments
- arg1 = enclID
- arg2 = slotNum
- arg3 = controller FQDD
- Detailed Description
- The physical drive identified in message cannot be discovered because of incompatibility issues. Some of the issues because of which a device cannot be discovered are as follows: 1) Missing namespace in NSID 1. 2) No namespace is created. 3) Logical Block Addressing (LBA) size is not either one of these: 512 B or 4K. 4) When the Protection Information (PI) feature is enabled.
- Recommended Response Action
- 1) Resolve the issue by using the instructions provided on the interface (for example, HII or PERC CLI).2) Else, if a resolution is not suggested by the interface because the interface does not support, do the following: 2a) Restart the server. 2b) When the company logo is displayed, press F2. 2b) Click Device Setting > Select the RAID Controller > Main Menu > Hardware Components > Enclosure Management. 3) If the issue persists, remove the NVMe drive identified in the message, and replace it with a working drive. If the issue is not resolved, contact your service provider. For more information about repairing issues in NVMe drives, see the relevant PERC Users Guide available on the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- OMSA Event ID
- 2486
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR395
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The physical drive repair operation is successfully started on the physical drive installed on the enclosure arg1, slot arg2, arg3.
- Arguments
- arg1 = enclID
- arg2 = slotNum
- arg3 = controller FQDD
- Detailed Description
- Thephysical drive repair operation is successfully started on the physical driveinstalled on the enclosure identified in the message.
- Recommended Response Action
- Noresponse action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2487
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR396
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The physical drive repair operation is successfully completed on the physical drive installed on the enclosure arg1, slot arg2, arg3.
- Arguments
- arg1 = enclID
- arg2 = slotNum
- arg3 = controller FQDD
- Detailed Description
- Thephysical drive repair operation is successfully completed on the physical driveinstalled on the enclosure identified in the message.
- Recommended Response Action
- Noresponse action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2488
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR397
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The repair operation was not successful because PERC is unable to resolve the incompatibility issue in the physical drive on enclosure arg1, slot arg2, arg3.
- Arguments
- arg1 = enclID
- arg2 = slotNum
- arg3 = controller FQDD
- Detailed Description
- The repair operation was not successful because PERC is unable to resolve the incompatibility issue in the physical drive on enclosure identified in the message.
- Recommended Response Action
- Replace the NVMe drive with a working drive, and then retry the operation. If the issue persists, contact your service provider. For more information about repairing issues in NVMe drives, see the relevant PERC Users Guide available on the support site.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2489
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR398
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Because of a user-initiated action, the physical drive repair operation is stopped on the physical drive installed on the enclosure arg1, slot arg2, arg3.
- Arguments
- arg1 = enclID
- arg2 = slotNum
- arg3 = controller FQDD
- Detailed Description
- Thephysical drive repair operation is stopped on the physical drive installed onthe enclosure identified in the message.
- Recommended Response Action
- Noresponse action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- OMSA Event ID
- 2490
- OMSA Trap ID
- 75100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
STOR4
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CEM Storage Management encountered internal error.
- Detailed Description
- There was a software problem in initializing the CEM storage management components. Storage inventory and monitoring will be affected.
- Recommended Response Action
- Reboot the system or iDRAC. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (STOR = Storage)
- Severity
- Critical
- Trap/EventID
- 4177
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR5
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Redundancy lost.arg1
- Arguments
- arg1 = VD/Enclosure Name
- Detailed Description
- A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed. Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional physical disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed. For example, the enclosure may have suffered the loss of all fans or all power supplies.
- Recommended Response Action
- Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components. Continue clicking the components with a Warning or Failed status until you identify the failed component. See Storage Health for more information. See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- OMSA Event ID
- 2123
- OMSA Trap ID
- 130600
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR5001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to manage the arg1 because of an internal error in the storage library.
- Arguments
- arg1 = controllerName
- Detailed Description
- The real-time inventory, monitoring, and configuration data of the controller identified in the message is unavailable because of a storage library internal error.
- Recommended Response Action
- Reset iDRAC. To reset iDRAC, run the following command at the Command Line Interface (CLI): "racadm racreset". If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR5002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- iDRAC is unable to discover PowerEdge RAID Controller(s) (PERCs) over sideband because of PCIe-VDM channel issues.
- Detailed Description
- iDRAC is unable to discover PowerEdge RAID Controller(s) over sideband because of PCIe-VDM channel issues.
- Recommended Response Action
- Restart iDRAC and check if the issue is resolved. To reset iDRAC by using a RACADM command, run the following command at the Command Line Interface (CLI): racadm racreset. If the issue persists, refer to the Troubleshooting" section in the iDRAC Users Guide.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- LCD Message
- iDRAC is unable to discover PowerEdge RAID Controller(s) (PERCs) over sideband because of PCIe-VDM channel issues.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR5003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Platform Issue was seen with MCTP PCIe-VDM transport binding hence IDRAC is switching has switched to I2C transport binding medium as a failover mechanism.
- Detailed Description
- Platform Issue was seen with MCTP PCIe-VDM transport binding hence IDRAC is switching has switched to I2C transport binding medium as a failover mechanism.
- Recommended Response Action
- No Action.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR515
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The System Firmware Intermediatory (SFI) arg1 on the NVMe device in the slotarg2, Bay arg3, is a arg4.
- Arguments
- arg1 = Operation
- arg2 = SlotID
- arg3 = Bayid
- arg4 = Status
- Detailed Description
- The System Firmware Intermediatory (SFI) operation on the NVMe device in the slot has achieved a status as identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR6
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- CEM Storage Management detected inventory change(s) after host re-boot.
- Detailed Description
- A comparison of storage inventory collected before and after the host re-boot/re-set. reports differences. There could have been some storage components added or removed when the host was powered down.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR7
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The storage management instrumentation is performing an inventory refresh operation.
- Detailed Description
- The storage monitoring instrumentation detected a burst of events from underlying storage controllers. To overcome this overload condition, all the outstanding events have been purged and a fresh inventory will be performed automatically.
- Recommended Response Action
- No response action is required.
- Category
- Storage (STOR = Storage)
- Severity
- Informational
- Trap/EventID
- 4179
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR703
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the prepare to remove operation for the NVMe device arg1 because the NVMe device state is either "sanitize in progress" or "sanitize failed".
- Arguments
- arg1 = device FQDD
- Detailed Description
- The prepare to remove operation cannot be performed for the NVMe device identified in the message because the NVMe device state is either "sanitize in progress" or "sanitize failed".
- Recommended Response Action
- Do one of the following and retry the operation: 1) Make sure the NVMe device is in the Ready state before starting the PrepareToRemove operation. 2) Enter the correct the ForceRemove parameter to perform the PrepareToRemove operation irrespective of the NVMe device state. To view the drive state, go to the respective Redfish Oem Drive URI.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR704
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to perform the arg1 for the arg2 because the physical device is in either the "Sanitize in Progress" or "Sanitize Failed" state.
- Arguments
- arg1 = Operation Type
- arg2 = device FQDD
- Detailed Description
- The operation cannot be completed for the physical device identified in the message because the physical device is in either the "Sanitize in Progress" or "Sanitize Failed" state.
- Recommended Response Action
- 1) If the Sanitize In Progress issue is observed, then wait for a few minutes and retry the operation. If the Sanitize In Progress issue is still observed, then power cycle the server and retry the operation.2) If the Sanitize Failed issue is observed, then retry the Sanitize operation.If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
STOR8
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Detected two RAID controllers in integrated slots. This configuration is not currently supported and the second controller will not be powered on.
- Detailed Description
- High Availability RAID is not supported by this firmware release. This event may occur during the upgrade process.
- Recommended Response Action
- Remove one RAID controller.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
STOR9
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- No RAID controllers have been detected. Access to shared storage will not be available.
- Detailed Description
- No supported RAID controllers have been detected. Access to shared storage will not be available.
- Recommended Response Action
- Ensure supported RAID controllers are installed.
- Category
- Storage (STOR = Storage)
- Severity
- Warning
- Trap/EventID
- 4178
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LCD
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\