Description | Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 193777 |
Description | TelemetryService Redfish URI /redfish/v1/TelemetryService continues to display the FQDD of a removed component under the path Dell OEM FQDDList. |
Workaround | Check the FQDDs in the hardware inventory. |
Systems Affected | All systems supported by this release. |
Tracking number | 202798 |
Description | Updating configuration for NVMe Over FC fails with an LC log error stating " Unable to configure the target settings properties of the Fibre Channel in Mezzanine 1C Port 1". |
Workaround | Change configuration through iDRAC HII with IOIDOpt Disabled. |
Systems Affected | All systems that support Qlogic FC adapter with NVMe Over FC features. |
Tracking number | 199872 |
Description | In RACADM cd mode, autocomplete action for FirstNVMeTarget returns incorrect suggestion list and for SecondNVMeTgt or SeventhNVMeTgt it does not return the expected output or stops the process. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 194894 |
Description | To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 183321 |
Description | Top query on a Parity URI instance returns complete response instead of an error code. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 175801 |
Description | iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries are seen under one sled even though only few are associated with that particular sled. |
Workaround | N/A |
Systems Affected | PowerEdge FC640, PowerEdge R740XD |
Tracking number | 172943 |
Description | While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 156737 |
Description | If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 151560 |
Description | Creating a recurring job will fail if the same job was completed recently and its Task ID still exists. |
Workaround | Wait for ten minutes for the Task ID to be deleted. |
Systems Affected | All systems supported by this release. |
Tracking number | 147501 |
Description | If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 111564 |