Creating RAID 10 configuration is not supported through Redfish interface. Use the other iDRAC interfaces to create a RAID 10 configuration.
Sometimes, when using WSMan, an Internal SSL Error is reported and the WSMan command fails. If this issue occurs, retry the command.
Using WSMan, the attribute
LCD.ChassisIdentifyDuration cannot be set to
-1 (indefinite blink). To make the LED blink indefinitely, use the
IdentifyChassis command with
IdentifyState=1.
RACADM supports the underscore character (_) for
iDRAC.SerialRedirection.QuitKey along with the existing symbols shown in the integrated help.
If iDRAC is in lockdown mode and you run the command 'racadm rollback', followed by the command 'racadm resetcfg', an incorrect message is displayed:
ERROR: A firmware update is currently in progress. Unable to reset the RAC at this time. Reboot iDRAC to display the correct error message.
While using a
Top or
Skip command, if you enter a value greater than the unsigned long type (4,294,967,295), you may get an incorrect error message.