Description | In certain configurations, if the NIC partitions are enabled, WWM/MAC page may display the MAC/WWN details for the Mezz cards that are installed in the system in random order. The display order may vary from the port or partition ordering. |
Workaround | Go to the Network device page for specific device details that are associated with port and partitions. |
Systems Affected | PowerEdge MX series |
Tracking number | 194452 |
Description | After setting iDrac static IP using IPV4 group (IPv4.1.Address, IPv4.1.Gateway,IPv4.1.Netmask) using Redfish or RACADM interface, a new IP address may not apply and system may become inaccessible. |
Workaround | Use the IPV4Static group (IPv4Static.1.Address, IPv4Static.1.Gateway,IPv4Static.1.Netmask) to set static IP address. |
Systems Affected | All systems supported by this release. |
Tracking number | 185458 |
Description | For some NIC or FC cards, even if the device slot is disabled in BIOS, the slot may still get listed in the hardware inventory. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 104535 |