Description | For a newly created firmware update job post an iDRAC update, Redfish may display 404 error if you perform a Get method to see the details for the job. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release |
Tracking number | 224189 |
Description | GPU temperature sensor may not display the relevant sensor information while using IPMI tool. |
Workaround | To access the information, use the iDRAC GUI, RACADM, or Redfish interfaces. |
Systems Affected | All systems supported by this release. |
Tracking number | 214501 |
Description | The RACADM ACK command may fail to clear any critical events displayed in the iDRAC summary, that are caused by hot plugging a 3.5" drive. |
Workaround | N/A |
Systems Affected | PowerEdge XE7420 and PowerEdge XE7440 |
Tracking number | 208273 |
Description | Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 193777 |
Description | To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 183321 |
Description | Top query on a Parity URI instance returns complete response instead of an error code. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 175801 |
Description | iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries are seen under one sled even though only few are associated with that particular sled. |
Workaround | N/A |
Systems Affected | PowerEdge FC640, PowerEdge R740XD |
Tracking number | 172943 |
Description | While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 156737 |
Description | If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 151560 |
Description | Creating a recurring job will fail if the same job was completed recently and its Task ID still exists. |
Workaround | Wait for ten minutes for the Task ID to be deleted. |
Systems Affected | All systems supported by this release. |
Tracking number | 147501 |
Description | If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 111564 |