- Release Summary
Description | SEL may display "CPU temperature is greater than the upper critical threshold" during an OS reboot. |
Workaround | Check the corrected SEL after the reboot operation is complete. |
Systems Affected | PowerEdge XE8545 |
Tracking number | 217677 |
Description | Lifecycle (LC) logs do not capture the chassis manager reset operation that is performed through RACADM interface. |
Workaround | N/a |
Systems Affected | All DCS systems supported by this release. |
Tracking number | 218483 |
Description | During an AC power cycle stress, random PR7 (New device detected) messages may get logged for devices such as CPU, DIMM, NICs, Storage Cards, and so on in the Lifecycle-Controller (LC) logs even though no actual hardware-related change was performed. There is no impact on device functionality. |
Workaround | N/A |
Systems Affected | PowerEdge R740, PowerEdge R640, PowerEdge R840, and PowerEdge T640 |
Tracking number | 208278 |
Description | Importing SCP file that was exported from a system with iDRAC version 5.00.15.00 to a system with iDRAC version 5.00.20.00 or later versions may fail. |
Workaround | Update the iDRAC version of the system exporting SCP file to iDRAC version 5.00.20.00 and the try exporting the file again. |
Systems Affected | All systems supported by this release. |
Tracking number | 213900 |
Description | New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event. |
Workaround | N/A |
Systems Affected | All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release. |
Tracking number | 186384 |
Description | PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 186119 |
Description | Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%. |
Workaround | Generate SupportAssist collection with only system information option checked. |
Systems Affected | All systems supported by this release. |
Tracking number | 159527 |
Description | After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 144819 and 141414 |
Description | When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 129440 |