After iSM is upgraded, LC logs may not report the upgrade with the ISM0007 message.
Workaround
N/a
Systems affected
All systems supported by this release.
Tracking number
202630
LC logs display incorrect message for PSU update
Description
While updating PSU firmware with an invalid DUP, LC logs may display "SWC5016 - "Unable to update the firmware of the chassis Power Supply Unit (PSU) because one or more sleds installed on the chassis are currently powered on.".
Workaround
N/a
Systems affected
All DCS sleds supported by this release.
Tracking number
196376
Getting RAC0182 message after upgrading iDRAC firmware
Description
LC logs may display the message "RAC0182: The iDRAC firmware was rebooted with the following reason: watchdog" on systems with Intel Ethernet 25G 2P E810-XXV adapter (Firmware v20.0.18), if iDRAC firmware is updated to version 5.xx.
Workaround
N/a
Systems affected
PowerEdge XE8545
Tracking number
200573
SEL events may not be correctly displayed in the earlier versions of iDRAC
Description
New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Workaround
N/a
Systems affected
All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release.
Tracking number
186384
PR1 & PR10 Lifecycle logs displayed during Retire and Repurpose operation
Description
PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Workaround
N/a
Systems affected
All systems supported by this release.
Tracking number
186119
SupportAssist collection failing
Description
Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.
Workaround
Generate SupportAssist collection with only system information option checked.
Systems affected
All systems supported by this release.
Tracking number
159527
After a warm reboot, LC logs display Disk Inserted
Description
After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Workaround
N/A
Systems affected
All systems supported by this release.
Tracking number
144819 and 141414
Repetitive PR7 messages related to PSU in LC logs after a system erase operation
Description
When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Workaround
N/A
Systems affected
All systems supported by this release.
Tracking number
129440