RFS may get disconnected if iDRAC IP is not reachable for some time.
Workaround
Reboot iDRAC.
Systems affected
All systems supported by this release.
Tracking number
201672
LC logs display incorrect version change for disks
Description
After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround
Restart the host system.
Systems affected
All systems supported by this release.
Tracking number
197049
Storage Devices displayed in gray text
Description
After a reboot stress followed by BIOS update, storage devices may appear as not ready or in gray text.
Workaround
Reset iDRAC.
Systems affected
All PowerEdge Rx5xx/Cx5xx series supported by this release.
Tracking number
194537
Deleting VD creates pending operation with empty data
Description
When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Workaround
To successfully delete the VD and add to pending operations, perform the following steps:
Select the Configuration option in iDRAC GUI
Select Storage Configuration, then select the Controller and click Apply now.
Systems affected
All systems supported by this release.
Tracking number
184393
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\