Part number for Predictive failure message "PDR16" for NVMe drive may appear as "Not Available" immediately after the cold reboot. Allow some time after the cold reboot for iDRAC to initialize the inventory.
While renaming a virtual disk (VD), using a . (period) is not allowed in the VD name.
If your system has a PERC card configured in Enhanced HBA mode and you downgrade iDRAC to an older version, the SET commands for storage configuration may fail. To resolve the issue, ensure that a Collect System Inventory On Reboot (CSIOR) is performed after the downgrade. To perform a CSIOR, use the following methods:
Completely turn off the system and then turn it on again.
Ensure that CSIOR is enabled before turning off the system.
Use the following RACADM command: racadm serveraction powercycle
Few legacy drives do not support the SMART ID #245 "Remaining Rated Write Endurance". In such cases, iDRAC interfaces may display the "Remaining Rated Write Endurance" attribute as unavailable.
If a M.2 SATA drive attached to BOSS-S2 controller is removed, performing a blink operation may not fail for the removed drive.