- Release Summary
Description | After BIOS recovery is complete, Auto Power-on not Initiating. |
Workaround | Power on the system manually to complete BIOS recovery process. |
Systems Affected | All 15th generation of PowerEdge servers with AMD. |
Tracking number | 232664/233395 |
Description | iDRAC GUI may not display the information about sensor, power, or voltage for PSUs. |
Workaround | Remove and reinstall the PSU while iDRAC is running. |
Systems Affected | PowerEdge XE8545 and PowerEdge R940XA. |
Tracking number | 231504/233949 |
Description | During an iDRAC firmware rollback or update or iDRAC reboot, if a configuration job is in scheduled or is in running state, then deleting the pending values from iDRAC GUI using "Discard ALL Pending" option may fail. |
Workaround | Use the RACADM interface (racadm jobqueue delete -i JID_CLEARALL_FORCE). |
Systems Affected | All systems supported by this release. |
Tracking number | 223742 |
Description | SubjectOrganizationalUnit field is not available in GUI or Redfish interface for any security certificates that are stored in iDRAC certificate store. |
Workaround | Use the RACADM command to view the field: racadm sslcertview |
Systems Affected | All systems supported by this release. |
Tracking number | 229355 |
Description | After performing a PSU firmware update through DUP method, only one sled powers on automatically while others remain powered off. |
Workaround | Use iDRAC GUI to power on the remaining sleds. |
Systems Affected | PowerEdge C6420 |
Tracking number | 209713 |
Description | Updating iDRAC firmware to version 4.40.00.00 or later may cause the vFlash partitions to detach on first boot after the update. |
Workaround | Reattach the detached vFlash partitions through any iDRAC interfaces after the first boot. |
Systems Affected | All systems supported by this release. |
Tracking number | 194849 |
Description | After updating backplane firmware to a newer version and then updating it back to a previous version from host OS, the backplane information is not displayed while trying to apply the firmware Rollback. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184368 |
Description | iDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings. |
Workaround | Configure NTP settings and export the Server configuration Profile. Import the Server configuration profile with NTP and manually configure SNTP settings. |
Systems Affected | All systems supported by this release. |
Tracking number | 181069 |
Description | While the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time. |
Workaround | N/A |
Systems Affected | All PowerEdge Rxxx5/Cxxx5 systems supported by this release. |
Tracking number | 183347 |
Description | iDRAC may display stale or inaccurate information when there is a communication failure between iDRAC and CMC. |
Workaround | N/A |
Systems Affected | PowerEdge FC640 |
Tracking number | 226633 |