Description | System fans may oscillate at 100% speed after a hot removal of M.2 drive that is configured through the BOSS-N1 controller. |
Workaround | Perform an iDRAC reset or power-cycle the system and then install the drive in the slot. |
Systems Affected | All systems supported by this release. |
Tracking number | 252187 |
Description | Firmware update may fail when initiated from OME Modular interface and the event "RED016: Mount of remote share failed" is logged in Lifecycle logs. |
Workaround | Retry the operation. |
Systems Affected | All systems supported by this release. |
Tracking number | 225663 |
Description | Getting an error "Unable to connect the viewer" accessing Virtual Console while iDRAC GUI is launched with HTTP IP address. |
Workaround | Launch iDRAC GUI with HTTPS IP address before launching the Virtual Console. |
Systems Affected | All systems supported by this release. |
Tracking number | 232462 |
Description | Virtual console display from iDRAC GUI is blurred for a fraction of second and gets corrected automatically when opened in Google chrome. |
Workaround | Use any other browser. |
Systems Affected | All systems supported by this release. |
Tracking number | 182595 |
Description | Some keys or key combination may not provide the correct output for languages other than English. |
Workaround | Use the physical keyboard or Windows On-Screen Keyboard. |
Systems Affected | All systems supported by this release. |
Tracking number | 181505 |
Description | Changing the Remote Presence Port number through virtual console settings page may cause a system restart, further causing a session timeout for iDRAC GUI. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 144597 |