Description | Server may report the error "HWC8010: Configuration error: Add-in card in slot x" after the server is restarted post a DPU card installation. |
Workaround | Ensure that the DPU card is installed in the PCIe Slot 1 in PowerEdge R650 and in Slot 2 in PowerEdge R750. |
Systems Affected | PowerEdge R650 and PowerEdge R750 |
Tracking number | 232953 |
Description | After setting iDrac static IP using IPV4 group (IPv4.1.Address, IPv4.1.Gateway,IPv4.1.Netmask) using Redfish or RACADM interface, a new IP address may not apply and system may become inaccessible. |
Workaround | Use the IPV4Static group (IPv4Static.1.Address, IPv4Static.1.Gateway,IPv4Static.1.Netmask) to set static IP address. |
Systems Affected | All systems supported by this release. |
Tracking number | 185458 |
Description | iDRAC interfaces only display partial information for the Mellanox network cards, such as, in InfiniBand mode the card is displayed as a NIC device. Also, no board manufacturer and version is available. |
Workaround | N/a |
Systems Affected | All systems supported by this release. |
Tracking number | 179265 |
Description | For some NIC or FC cards, even if the device slot is disabled in BIOS, the slot may still get listed in the hardware inventory. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 104535 |