Description | Some values of AttributeName property in RegistryEntries property are noncompliant in the URI
/redfish/v1/Registries/NetworkAttributesRegistry_<Id>/NetworkAttributesRegistry_<Id>.jsonwith the AttributeRegistry schema. |
Workaround | N/A |
Systems Affected | PowerEdge XR4520c and PowerEdge XR4510c |
Tracking number | 258466 |
Description | Server Configuration Profile (SCP) imports using Redfish, polling TaskState property for TaskService task ID reports it as complete while the task is still running and percent complete reports it as 43. |
Workaround | Wait for the task ID status until percent complete reports 100. |
Systems Affected | All systems supported by this release |
Tracking number | 241366 |
Description | For Redfish OEM actions ExportLCLog and ExportHWInventory, the final job status message is not consistent across all supported network share protocols. When using NFS or CIFS share, final job status message is "<operation name> was successful" and while using HTTP or HTTPS, final job status message is "The command was successful". |
Workaround | To view what operation was performed, see the JobType property in the job ID JSON output results. |
Systems Affected | All systems supported by this release |
Tracking number | 231221 |
Description | SerialNumber property for Certificate URI not displaying the certificate in a format defined by the schema. |
Workaround | N/A |
Systems Affected | All systems supported by this release |
Tracking number | 247212 |
Description | After a chassis reset that is performed through Redfish, if the ResetType is set to PowerCycle, then system may power off and fail to power on automatically. |
Workaround | Power on the system using any iDRAC interface. |
Systems Affected | All systems supported by this release |
Tracking number | 234900 |
Description | While applying firmware update through Redfish interface for a device that does not require a reboot for the update, setting @Redfish.OperationApplyTime property to Immediate in the request body may cause the server to reboot. |
Workaround | N/A |
Systems Affected | All systems supported by this release |
Tracking number | 233764 |
Description | For a newly created job, Redfish may display 404 error if you perform a Get method to see the details for the job. |
Workaround | Wait for some time and try performing the Get method again. |
Systems Affected | All systems supported by this release |
Tracking number | 224189 |
Description | Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 193777 |
Description | To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 183321 |
Description | Top query on a Parity URI instance returns complete response instead of an error code. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 175801 |
Description | While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 156737 |
Description | If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 151560 |
Description | Creating a recurring job will fail if the same job was completed recently and its Task ID still exists. |
Workaround | Wait for ten minutes for the Task ID to be deleted. |
Systems Affected | All systems supported by this release. |
Tracking number | 147501 |
Description | If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 111564 |