Description | The following Telemetry reports may intermittently miss a few metrics: PowerMetrics, PSUMetrics, ThermalMetrics, StorageSensor, MemeorySensor, AggregationMetrics, SystemUsage, FPGASensor, PowerStataistics, PowerStatistics, CPUMemMetrics. |
Workaround | Perform any of the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 259718 |
Description | New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event. |
Workaround | N/A |
Systems Affected | All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release. |
Tracking number | 186384 |
Description | PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 186119 |
Description | After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 144819 and 141414 |
Description | When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 129440 |