The following table lists the battery specifications of your
Inspiron 15 3530.
Table 1. Battery specifications
The following table provides the detailed battery specifications of
Inspiron 15 3530.
Description
Option one
Option two
Battery type
3-cell, 41 Wh, lithium-polymer, ExpressCharge
4-cell, 54 Wh, lithium-polymer, ExpressCharge
Battery voltage
11.25 VDC
15.00 VDC
Battery weight (maximum)
0.19 kg (0.41 lb)
0.24 kg (0.55 lb)
Battery dimensions:
Height
206.40 mm (8.12 in.)
271.90 mm (10.70 in.)
Width
82.00 mm (3.22 in.)
82.00 mm (3.22 in.)
Depth
5.75 mm (0.22 in.)
5.75 mm (0.22 in.)
Temperature range:
Operating
When charging battery:
Initiating charging: 0°C to 45°C (32°F to 113°F)
Upper limit for charging (maximum): 50°C (122°F)
When discharging battery:
Normal discharging: 0°C to 60°C (32°F to 140°F)
Over temperature protection (maximum): 70°C (158°F)
NOTE:The battery does not allow discharge past this temperature.
When charging battery:
Initiating charging: 0°C to 45°C (32°F to 113°F)
Upper limit for charging (maximum): 50°C (122°F)
When discharging battery:
Normal discharging: 0°C to 60°C (32°F to 140°F)
Over temperature protection (maximum): 70°C (158°F)
NOTE:The battery does not allow discharge past this temperature.
Storage
–20°C to 60°C (-4°F to 140°F)
–20°C to 60°C (-4°F to 140°F)
Battery operating time
Varies depending on operating conditions and can
significantly reduce under certain power-intensive conditions
Varies depending on operating conditions and can significantly
reduce under certain power-intensive conditions
Battery charging time (approximate)
NOTE:You can control the
charging time, duration, start and end time, and so on, using the
settings on the MyDell (replaced with Dell Optimizer) application
(Power option). For more information about MyDell application,
search Dell Support Site.
Standard Charge/Predominately AC User Charge Method:
0 - 15°C maximum allowable charge time from 0 to 100% RSOC is 4 hours
16 - 50°C maximum allowable charge time from 0 to 100% RSOC is 3 hours
Express Charge Method:
0 - 15°C maximum allowable charge time from 0 to 100% RSOC is 4 hours
16 - 45°C normal express charge
46 - 50°C maximum allowable charge time from 0 to 80% RSOC is 1 hours charge time from 0 to 100% RSOC is 2 hours
Express Charge Boost Charge Method (Fast Charge for Initial 35%):
16 - 45°C target charge time from 0 to 35% RSOC is 20 mins
Standard Charge/Predominately AC User Charge Method:
0 - 15°C maximum allowable charge time from 0 to 100% RSOC is 4 hours
16 - 50°C maximum allowable charge time from 0 to 100% RSOC is 3 hours
Express Charge Method:
0 - 15°C maximum allowable charge time from 0 to 100% RSOC is 4 hours
16 - 45°C normal express charge
46 - 50°C maximum allowable charge time from 0 to 80% RSOC is 1 hours charge time from 0 to 100% RSOC is 2 hours
Express Charge Boost Charge Method (Fast Charge for Initial 35%):
16 - 45°C target charge time from 0 to 35% RSOC is 20 mins
Coin-cell battery
Not supported
Not supported
CAUTION:Operating and storage temperature ranges may differ among components, so operating or storing the device outside these ranges may impact the performance of specific components.
CAUTION:Dell Technologies recommends that you charge the battery regularly for optimal power consumption.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\