Integrated Dell Remote Access Controller 8 (iDRAC8) Version 2.00.00.00 RACADM Command Line Interface Reference Guide
storage
- To generate and view information about the inventory of controllers,
virtual disks, storage enclosures, and physical disk drives.
- To generate and view information about the inventory of storage
root node.
This command retrieves the status.
racadm storage get status
raid Root Node Status : Ok
- To generate and view information about the inventory of controllers
connected to the server.
racadm storage get controllers RAID.Integrated.1-1This command is an optimized version and displays the full controller objects along with their keys.This command displays the filtered property values for all returned controller objects.racadm storage get controllers -o RAID.Integrated.1-1 Status = Ok DeviceDescription = Integrated RAID Controller 1 RollupStatus = Ok Name = PERC H730P Mini (Embedded) FirmwareVersion = 25.2.1.0025 DriverVersion = Information Not Available RebuildRate = 45 BgiRate = 13 CheckConsistencyRate = 18 ReconstructRate = 12 PatrolReadRate = 21 PatrolReadMode = Disabled PatrolReadState = Stopped CheckConsistencyMode = Normal LoadBalanceSetting = Disabled CopybackMode = OFF PreservedCache = Not Present CacheMemorySize = 2048 MB PersistHotspare = Disabled SpindownUnconfiguredDrives = Disabled SpindownHotspare = Disabled Timeintervalforspindown = 30 (Minutes) SecurityStatus = Security Key Assigned EncryptionMode = Supported with LKM SasAddress = 0x5B8CA3A0F3073700 PciDeviceId = 0x5d PciSubdeviceId = 0x1f47 PciVendorId = 0x1000 PciSubvendorId = 0x1028 PciBus = 0x3 PciDevice = 0x0 PciFunction = 0x0 BusWidth = Unknown SlotLength = Unknown SlotType = Unknown MaxCapableSpeed = 12.0 Gb/s LearnMode = Not supported T10PICapability = Capable SupportRAID10UnevenSpans = Supported SupportEnhancedAutoForeignImport = Supported EnhancedAutoImportForeignConfig = Enabled SupportControllerBootMode = Supported ControllerBootMode = Continue Boot On Error RealtimeConfigurationCapability = Capable CurrentControllerMode = RAIDracadm storage get controllers -o -p Name RAID.Integrated.1-1 Name = PERC H710P Adapter (Embedded)This command displays the operations pending on the controller.racadm storage get <controller> -pending RAID.Integrated.1-1 raid.Slot.2-1 - To generate and view information about the inventory of batteries
connected to the controller.
racadm storage get batteries
This command is an optimized version and displays the batteries along with their keys.racadm storage get batteries -o Battery.Integrated.1:RAID.Integrated.1-1 Name = Battery DeviceDescription = Battery on Integrated raid Controller 1 Status = Ok State = ReadyThis command displays the filtered property values for all battery objects.racadm storage get batteries -o -p Name Battery.Integrated.1:RAID.Integrated.1-1 Name = BatteryThis command displays all battery keys connected to the controllers.racadm storage get batteries --refkey RAID.Integrated.1-1 Battery.Integrated.1:RAID.Integrated.1-1This command is an optimized and filtered version.racadm storage get batteries --refkey RAID.Integrated.1-1 -o -p Name Battery.Integrated.1:RAID.Integrated.1-1 Name = Battery - To generate and view information about the inventory of virtual
disks connected to the controller.
racadm storage get vdisks Disk.Virtual.0:RAID.Integrated.1-1This command displays all virtual disk keys connected to the controllers.racadm storage get vdisks --refkey RAID.Integrated.1-1 Disk.Virtual.0:RAID.Integrated.1-1This command is an optimized and filtered version.racadm storage get vdisks -o -p DeviceDescription,OperationalState Disk.Virtual.0:RAID.Integrated.1-1 DeviceDescription = Virtual Disk 0 on Integrated raid Controller 1 OperationalState = Not applicable - To generate and view information about the inventory of virtual
disks.
racadm storage get vdisks -o Disk.Virtual.2:RAID.Integrated.1-1Status
OkDeviceDescription
Virtual Disk 2 on Integrated RAID Controller 1Name
OSRollupStatus
OkState
Online
OperationalState
Not applicable
Layout
Raid-0Size
278.88 GBSpanDepth
1
AvailableProtocols
SAS
MediaType
HDD
ReadPolicy
Read Ahead
WritePolicy
Write Back
StripeSize
64K
DiskCachePolicy
Default
BadBlocksFound
NO
Secured
NO
RemainingRedundancy
0EnhancedCache
Not ApplicableT10PIStatus
Disabled
BlockSizeInBytes
512
- To generate and view information about the inventory of storage
enclosures connected to the connector.
This command displays all enclosure objects for the connector FQDD.This command is an optimized and filtered version.
racadm storage get enclosures -o Enclosure.Internal.0-1:RAID.Integrated.1-1This command displays all enclosure keys connected to the connectors.Status Ok DeviceDescription Backplane 1 on Connector 0 of Integrated RAID Controller 1 RollupStatus Ok Name BP13G+EXP 0:1 BayId 1 FirmwareVersion 0.23 SasAddress 0x500056B31234ABFD SlotCount 24 racadm storage get enclosures --refkey RAID.Integrated.1-1 Enclosure.Internal.0-1:RAID.Integrated.1-1racadm storage get enclosures --refkey RAID.Integrated.1-1 -o -p Name Enclosure.Internal.0-1:RAID.Integrated.1-1 Name = BP12G+EXP 0:1 - To generate and view information about the inventory of physical
disk drives connected to the enclosure or backplanes.
racadm storage get pdisks Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1This command is an optimized version and displays the full controller objects along with their keys.racadm storage get pdisks -o racadm storage get pdisks Disk.Bay.23:Enclosure.Internal.0-1:RAID.Integrated.1-1 Status = Ok DeviceDescription = Disk 23 in Backplane 1 of Integrated RAID Controller 1 RollupStatus = Ok Name = Physical Disk 0:1:23 State = Online OperationState = Not Applicable PowerStatus = Spun-Up Size = 558.38 GB FailurePredicted = NO RemainingRatedWriteEndurance = Not Applicable SecurityStatus = Not Capable BusProtocol = SAS MediaType = HDD UsedRaidDiskSpace = 136.13 GB AvailableRaidDiskSpace = 0.00 GB Hotspare = NO Manufacturer = SEAGATE ProductId = ST9600204SS Revision = FM08 SerialNumber = 6WN09DXN PartNumber = CN07T0DW7262211M01Y6A00 NegotiatedSpeed = 6.0 Gb/s ManufacturedDay = 2 ManufacturedWeek = 4 ManufacturedYear = 2011 SasAddress = 0x5000C5003324E93D FormFactor = 2.5 Inch RaidNominalMediumRotationRate = 10000 T10PICapability = Not Capable BlockSizeInBytes = 512 MaxCapableSpeed = 6 Gb/sThis command displays the filtered property values for all returned controller objects.racadm storage get pdisks -o -p State Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 State = OnlineThis command displays all physical disk drive keys connected to the enclosures.This command is an optimized version and displays all disk objects for the enclosure FQDD.racadm storage get pdisks --refkey RAID.Integrated.1-1 Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o racadm storage get pdisks -o Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 Status = Ok DeviceDescription = Disk 0 in Backplane 1 of Integrated raid Controller 1 RollupStatus = Ok Name = Physical Disk 0:1:0 State = Online OperationState = Not Applicable PowerStatus = Spun-Up Size = 278.88 GB FailurePredicted = NO RemainingRatedWriteEndurance = Not Applicable SecurityStatus = Not Capable BusProtocol = SAS MediaType = HDD UsedraidDiskSpace = 278.88 GB AvailableraidDiskSpace = 0.00 GB Hotspare = NO Manufacturer = SEAGATE ProductId = ST9300605SS Revision = CS05 SerialNumber = 6XP40SA9 PartNumber = CN0745GC7262228706R7A00 NegotiatedSpeed = 6.0 Gb/s ManufacturedDay = 4 ManufacturedWeek = 32 ManufacturedYear = 2012 SasAddress = 0x5000C5005952386D FormFactor = 2.5 Inch raidNominalMediumRotationRate = 10000 T10PICapability = Not Capable BlockSizeInBytes = 512 MaxCapableSpeed = 6 Gb/sThis command is an optimized and filtered version.racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o -p State Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 State = Online - To generate and view information about the inventory of fans connected
to the enclosure.
This command displays all the fan keys connected to the enclosures.This command displays all the fan objects for the enclosure FQDD.
racadm storage get fans --refkey <enclosure FQDDs separated by comma>racadm storage get fans --refkey <enclosure FQDDs separated by comma > -oracadm storage get fans --refkey <enclosure FQDDs separated by comma> -o -p <property names separated by comma> - To generate and view information about the inventory of EMMs connected
to the enclosure.
This command returns all the EMM keys connected to the enclosures.This command is an optimized version and displays all the EMM objects for the enclosure FQDD.
racadm storage get emms -refkey <enclosure FQDDs separated by commaenclosure FQDDs separated by comma>racadm storage get emms --refkey <enclosure FQDDs separated by comma> -oThis command is an optimized and filtered version.racadm storage get emms --refkey <enclosure FQDDs separated by comma > -o -p <property names separated by comma> - To generate and view information about the inventory of PSU connected
to the enclosure.
This command displays all the PSUs connected to the enclosures.This command is an optimized version and displays all the PSUs objects for the enclosure FQDD.
racadm storage get psus --refkey <enclosure FQDD's separated by comma>racadm storage get psus --refkey <enclosure FQDD's separated by comma > -oThis command is an optimized and filtered version.racadm storage get psus --refkey <enclosure FQDD's separated by comma> -o -p <property names separated by comma>
- To generate and view information about the inventory of storage
root node.
- To get the list of enclosures and properties of the PCIeSSD enclosure.
- This command provides the list of enclosures.
racadm storage get enclosures Enclosure.Internal.0-1:RAID.Integrated.1-1\ Enclosure.Internal.0-1:PCIeExtender.Slot.3 - This command provides the properties of the specified PCIeSSD
enclosure.
racadm storage get enclosures:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Enclosure.Internal.0-1:PCIeExtender.Slot.3 RollupStatus = Ok DeviceDescription = Enclosure.Internal.0-1:PCIeExtender.Slot.3 Name = PCIe SSD BP 1 SlotCount = 4 FirmwareVersion = 0.80
- This command provides the list of enclosures.
- To create, delete, and secure the virtual disks.
- This command creates a virtual disk.
racadm storage createvd:RAID.Integrated.1-1 -rl r0 -pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
- This command starts an initialization operation on a specified
virtual disk.
racadm storage init:Disk.Virtual.0:RAID.Integrated.1-1 -speed fast
- This command deletes the specified virtual disk.
racadm storage deletevd:Disk.Virtual.0:RAID.Integrated.1-1
- This command encrypts the specified virtual disk.
racadm storage encryptvd:Disk.Virtual.0:RAID.Integrated.1-1
- This command assigns security key for controller.
racadm storage createsecuritykey:RAID.Integrated.1-1 -key <Key id> -passwd <passphrase>
- This command modifies security key for controller.
racadm storage modifysecuritykey:RAID.Integrated.1-1 -key <Key id> -oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
- This command deletes security key for controller.
racadm storage deletesecuritykey:RAID.Integrated.1-1
- This command creates a virtual disk.
- To convert the physical disk drive and assign hot-spare.
- This command converts the specified non-storage physical disk
drive to a storage capable physical disk drive.
racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
- This command converts the specified physical disk drive to a non-storage
physical disk drive.
racadm storage converttononraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
- This command assigns or unassign a global or dedicated hot-spare.
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign no
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type ghs
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
- This command converts the specified non-storage physical disk
drive to a storage capable physical disk drive.
- To get the list of physical disks and properties of the specified
PCIeSSD physical disk.
-
This command provides the list of physical disks.
racadm storage get pdisks Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Disk.Bay.6:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Disk.Bay.7:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Disk.Bay.9:Enclosure.Internal.0-1:PCIeExtender.Slot.3 -
This command provides the properties of the specified PCIeSSD physical disk.
racadm storage get pdisks:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 Status = Ok DeviceDescription = PCIe Solid-State Drive in Slot 8 in Bay 1 Name = Physical Device 8 State = Ready Size = 745.21 GB BusProtocol = PCIe MediaType = SSD Model = SAMSUNG MZWEI800HAGM 000D3 ProductId = a820 SerialNumber = S1J1NYAD90019 DeviceProtocol = NVMe1.0 Manufacturer = SAMSUNG PCIeNegotiatedLinkWidth = x4 PCIeCapableLinkWidth = x4 MaxCapableSpeed = 8 GT/s NegotiatedSpeed = 8 GT/s FormFactor = 2.5 Inch Revision = IPM0ED35SAM SAMSUNG MZWEI800HAGM 000D3 RemainingRatedWriteEndurance = 100 % FailurePredicted = NO
-
- To reset, clear, and import the storage configuration to the controller.
- This command imports the current foreign configuration from the
controller.
racadm storage importconfig:RAID.Integrated.1-1
- This command clears the current foreign configuration from the
controller.
racadm storage resetconfig:RAID.Integrated.1-1
- This command deletes the virtual disk from the controller.
racadm storage clearconfig:RAID.Integrated.1-1
- This command imports the current foreign configuration from the
controller.
- To get the list of controllers and properties of the PCIeSSD controller.
-
This command provides the list of controllers.
racadm storage get controllers RAID.Integrated.1-1 PCIeExtender.Slot.3 -
This command provides the properties of the specified PCIeSSD controller.
racadm storage get controllers:PCIeExtender.Slot.3 PCIeExtender.Slot.3 RollupStatus = Ok DeviceDescription = PCIe Extender in PCIe Slot 3 Status = Ok Name = PCIeExtender 3 (PCI Slot 3)
-
-
To blink or unblink the PCIeSSD device.
-
This command will blink the specified PCIeSSD device.
racadm storage blink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 STOR095 : Storage operation is successfully completed. -
This command will unblink the specified PCIeSSD device.
racadm storage unblink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 STOR095 : Storage operation is successfully completed.
-
-
To prepare the specified PCIeSSD device for removal
racadm storage preparetoremove: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 STOR089 : Successfully accepted the storage configuration operation. To apply the configuration operation, create a configuration job with --realtime option. To create the required commit jobs, run the jobqueue command. For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue” -
To perform a secure erase on the specified PCIeSSD device.
racadm storage secureerase: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3 RAC1040 : Successfully accepted the storage configuration operation. To apply the configuration operation, create a configuration job, and then restart the server. To create the required commit and reboot jobs, run the jobqueue command. For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue”