Dell Open Server Manager built on OpenBMC™ 3.0.2 User's Guide
Install iDRAC using Open Server Manager web UI
- Log in to the Open Server Manager user interface.
NOTE: You are required to update to OSM 3.0.2 from older versions and flash BIOS or CPLD (FPGA) before converting to iDRAC10. OSM 3.0.0 and OSM 3.0.1 do not support converting to iDRAC10.NOTE: The minimum BIOS firmware version should be 1.1.3 for conversion.
- Click .
- Click Add File and upload the image file.
- A message is displayed indicating that the upload process is started.

- After uploading, click
Activiate in the
Uploaded image section.

- To active the uploaded iDRAC image file immediately, click
Now.

The server is automatically restarted to make the update effective. The server takes a few minutes to update and ping the iDRAC IP. If the host fails to shutdown with a graceful shutdown command, ensure to manually turn off the host for the update to progress.
NOTE: If you select Later, then the iDRAC firmware update is scheduled for later and is not applied until you either power off the server. - Wait several minutes for iDRAC to install and start. After it is available, start the iDRAC web UI using the iDRAC IP address.
NOTE:The iDRAC network settings are separate from the Open Server Manager network settings and may be different. See the iDRAC User's Guide available at iDRAC manuals page to configure the iDRAC network settings.