- Do a GET request on /redfish/v1/UpdateService.
-
Verify if
HttpPushUriApplyTime is set to immediate. If not, set it to immediate using a
PATCH operation.
{ { "HttpPushUriOptions": { "HttpPushUriApplyTime": { "ApplyTime": "Immediate" } } } -
Do a
POST request with the binary of the iDRAC DUP file to
/redfish/v1/UpdateService. A task URI is returned. You can monitor the task using this URI.
{ "@odata.id": "/redfish/v1/TaskService/Tasks/2", "@odata.type": "#Task.v1_4_3.Task", "Id": "2", "TaskState": "Running", "TaskStatus": "OK" }NOTE:The connection to the BMC host is ended now.NOTE: You are required to update to OSM 3.0.2 from older versions and flash BIOS or CPLD (FPGA) before converting to iDRAC10. OSM 3.0.0 and OSM 3.0.1 do not support converting to iDRAC10.NOTE: The minimum BIOS firmware version should be 1.1.3 for conversion.