getsensorinfo
Table 1. Details of getsensorinfoThe following table provides details about the getsensorinfo subcommand:
| getsensorinfo
|
| Description
|
Displays the status for system sensors.
NOTE:For the Dell PowerEdge FX2 chassis with the FM120x4 server, the power-related information is not displayed.
|
| Synopsis
|
-
racadm getsensorinfo
-
racadm getsensorinfo -c
|
| Input
|
-c—Compact output format.
|
NOTE:Chassis Controller is supported only on PowerEdge FX2, and GPU sensors are displayed only on PowerEdge C4140 servers.
Example
racadm getsensorinfo
Sensor Type : POWER
NOTE:For current information of supported properties and their values, see the iDRAC Online Help.
Table 2. racadm getsensorinfo Sensor Type : POWERThe following table explains about racadm getsensorinfo Sensor Type : POWER:
|
<Sensor Name>
|
<Status>
|
<Type>
|
<Input Power>
|
|
PS1 Status
|
Present
|
AC
|
Watts
|
|
PS2 Status
|
AC-Lost
|
AC
|
Watts
|
Sensor Type : TEMPERATURE
Table 3. Sensor Type : TEMPERATUREThe following table explains about Sensor Type : TEMPERATURE:
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
<Inc>[R/W]
|
<Unc>[R/W]
|
|
System Board Inlet Temp
|
Ok
|
20 C
|
-7 C
|
47 C
|
3 C [Y]
|
42C [Y]
|
|
System Board Exhaust Temp
|
Ok
|
19 C
|
0 C
|
75 C
|
0 C [N]
|
70 C [N]
|
|
CPU1 Temp
|
Ok
|
59 C
|
3 C
|
97 C
|
8 C [N]
|
92 C [N]
|
Sensor Type : FAN
Table 4. Sensor Type : FANThe following table explains about Sensor Type Sensor Type : FAN:
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
<PWM %>
|
|
System Board Fan1 RPM
|
Ok
|
5880 RPM
|
600 RPM
|
NA
|
21%
|
|
System Board Fan2 RPM
|
Ok
|
6000 RPM
|
600 RPM
|
NA
|
0%
|
|
System Board Fan3 RPM
|
Ok
|
5880 RPM
|
600 RPM
|
NA
|
0%
|
|
System Board Fan4 RPM
|
Ok
|
5880 RPM
|
600 RPM
|
NA
|
0%
|
|
System Board Fan5 RPM
|
Ok
|
5640 RPM
|
600 RPM
|
NA
|
144%
|
|
System Board Fan6 RPM
|
Ok
|
5880 RPM
|
600 RPM
|
NA
|
152%
|
Sensor Type : VOLTAGE
Table 5. Sensor Type : VOLTAGEThe following table explains about Sensor Type : VOLTAGE :
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
|
CPU1 VCORE PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 3.3V PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 5V AUX PG
|
Ok
|
Good
|
NA
|
NA
|
|
CPU1 M23 VPP PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 1.05V PG
|
Ok
|
Good
|
NA
|
NA
|
|
CPU1 M23 VDDQ PG
|
Ok
|
Good
|
NA
|
NA
|
|
CPU1 M23 VTT PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 5V SWITCH PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board VCCIO PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 2.5V AUX PG
|
Ok
|
Good
|
NA
|
NA
|
|
PS1 Voltage 1
|
Ok
|
-28.00V
|
NA
|
NA
|
|
PS1 Voltage 2
|
Ok
|
0.00V
|
NA
|
NA
|
|
CPU1 M01 VDDQ PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board NDC PG
|
Ok
|
Good
|
NA
|
NA
|
|
CPU1 M01 VPP PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 1.5V PG
|
Ok
|
Good
|
NA
|
NA
|
|
System Board PS2 PG Fail
|
Ok
|
Good
|
NA
|
NA
|
|
System Board PS1 PG Fail
|
Ok
|
Good
|
NA
|
NA
|
|
System Board 1.5V AUX PG
|
Ok
|
Good
|
NA
|
NA
|
|
CPU1 M01 VTT PG
|
Ok
|
Good
|
NA
|
NA
|
|
PS1 Voltage 1
|
Ok
|
240 V
|
NA
|
NA
|
| System Board DIMM PG
|
Ok
|
Good
|
NA
|
NA
|
Sensor Type : CURRENT
Table 6. Sensor Type : CURRENTThe following table explains about Sensor Type : CURRENT:
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
<Inc> [R/W]
|
<unc> [R/W]
|
|
PS1 Current 1
|
Ok
|
0.4 Amps
|
NA
|
NA
|
0 Amps [N]
|
0 Amps [N]
|
|
System Board Pwr Consumption
|
Ok
|
56 Watts
|
NA
|
1386 Watts
|
0 Watts [N]
|
1260 Watts [N]
|
Sensor Type : PROCESSOR
Table 7. Sensor Type : PROCESSORThe following table explains about Sensor Type : PROCESSOR:
|
<Sensor Name>
|
<Status>
|
<State>
|
<lc>
|
<uc>
|
|
CPU1 Status
|
Ok
|
Presence Detected
|
NA
|
NA
|
|
CPU2 Status
|
N/A
|
Absent
|
NA
|
NA
|
Sensor Type : MEMORY
Table 8. Sensor Type : MEMORYThe following table explains about Sensor Type : MEMORY :
|
<Sensor Name>
|
<Status>
|
<State>
|
<lc>
|
<uc>
|
|
DIMM A1
|
N/A
|
Presence Detected
|
NA
|
NA
|
|
DIMM A2
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A3
|
Ok
|
Absent
|
NA
|
NA
|
|
DIMM A4
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A5
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A6
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A7
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A8
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A9
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A10
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A11
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM A12
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B1
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B2
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B3
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B4
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B5
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B6
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B7
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B8
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B9
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B10
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B11
|
N/A
|
Absent
|
NA
|
NA
|
|
DIMM B12
|
N/A
|
Absent
|
NA
|
NA
|
Sensor Type : Chassis Controller
Table 9. Sensor Type : Chassis ControllerThe following table explains about Sensor Type : Chassis Controller :
|
<Sensor Name>
|
<Status>
|
<State>
|
|
Chassis Controller
|
OK
|
OK
|
Sensor Type : BATTERY
Table 10. Sensor Type : BATTERYThe following table explains about Sensor Type : BATTERY :
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
|
System Board CMOS Battery
|
Ok
|
Present
|
NA
|
NA
|
|
PERC1 ROMB Battery
|
Ok
|
Unknown
|
NA
|
NA
|
| PERC2 ROMB Battery
|
Ok
|
Unknown
|
NA
|
NA
|
Sensor Type : PERFORMANCE
Table 11. Sensor Type : PERFORMANCEThe following table explains about Sensor Type : PERFORMANCE :
|
<Sensor Name>
|
<Status>
|
<Status>
|
<lc>
|
<uc>
|
|
System Board Power Optimized
|
Ok
|
Not Degraded
|
NA
|
NA
|
Sensor Type : INTRUSION
Table 12. Sensor Type : INTRUSIONThe following table explains about Sensor Type : INTRUSION :
|
<Sensor Name>
|
<Intrusion>
|
<Status>
|
|
System Board Intrusion
|
Closed
|
Power ON
|
Sensor Type : REDUNDANCY
Table 13. Sensor Type : REDUNDANCYThe following table explains about Sensor Type : REDUNDANCY :
|
<Sensor Name>
|
<Status>
|
<Type>
|
|
System Board Fan Redundancy
|
Full Redundant
|
Fan
|
|
System Board PS Redundancy
|
Disabled
|
PSU
|
Sensor Type : SYSTEM PERFORMANCE
Table 14. Sensor Type : SYSTEM PERFORMANCEThe following table explains about Sensor Type : SYSTEM PERFORMANCE :
|
<Sensor Name>
|
<Status>
|
<Reading>
|
<lc>
|
<uc>
|
<Inc> [R/W]
|
<unc> [R/W]
|
|
System Board CPU Usage
|
Non-Critical
|
0%
|
0%
|
100%
|
0% [N]
|
99% [Y]
|
| System Board IO Usage
|
Non-Critical
|
0%
|
0%
|
100%
|
0% [N]
|
99% [Y]
|
| System Board MEM Usage
|
Non-Critical
|
0%
|
0%
|
100%
|
0% [N]
|
99% [Y]
|
| System Board SYS Usage
|
Non-Critical
|
0%
|
0%
|
100%
|
0% [N]
|
99% [Y]
|
Table 15. Sensor Type : GPU PowerThe following table explains about Sensor Type : GPU Power :
|
<Sensor Name>
|
<PwrConsumption>
|
<PwrSupplyStatus>
|
<BoardPwrSupplyStatus>
|
|
Video.Slot.1
|
4.3MW
|
Enabled
|
Disabled
|
| Video.Slot.3
|
4.3MW
|
Enabled
|
Disabled
|
| Video.Slot.5
|
4.3MW
|
Enabled
|
Disabled
|
| Video.Slot.4
|
4.3MW
|
Enabled
|
Disabled
|
| Video.Slot.8
|
4.3MW
|
Enabled
|
Disabled
|
Table 16. Sensor Type : GPU TemperatureThe following table explains about Sensor Type : GPU Temperature :
|
<Sensor Name>
|
<GPU Temperature>
|
<SecondaryGPUTemp>
|
<BoardTemp>
|
<MemoryTemp>
|
|
Video.Slot.1
|
29C
|
255C
|
255C
|
255C
|
| Video.Slot.3
|
56C
|
255C
|
255C
|
255C
|
| Video.Slot.5
|
57C
|
255C
|
255C
|
255C
|
| Video.Slot.4
|
32C
|
255C
|
255C
|
255C
|
| Video.Slot.8
|
30C
|
255C
|
255C
|
255C
|
Table 17. Sensor Type : GPU ThermalThe following table explains about Sensor Type : GPU Thermal :
|
<Sensor Name>
|
<GPU Target Temp>
|
<MinGPUHwSlowdownTemp>
|
<GPUShutdownTemp>
|
<MaxMemoryOperatingTemp>
|
<MaxGPUOperatingTemp>
|
<ThermalAlertStatus>
|
<PowerBrakeStatus>
|
|
Video.Slot.1
|
255C
|
255C
|
255C
|
255C
|
255C
|
Disabled
|
Disabled
|
| Video.Slot.3
|
255C
|
255C
|
255C
|
255C
|
255C
|
Disabled
|
Disabled
|
| Video.Slot.5
|
255C
|
255C
|
255C
|
255C
|
255C
|
Disabled
|
Disabled
|
| Video.Slot.4
|
255C
|
255C
|
255C
|
255C
|
255C
|
Disabled
|
Disabled
|
| Video.Slot.8
|
255C
|
255C
|
255C
|
255C
|
255C
|
Disabled
|
Disabled
|
Table 18. Sensor Type : MAX DIMM TEMPERATUREThe following table explains about Sensor Type: MAX DIMM Temperature
| Sensor Name
|
Reading
|
| Max DIMM Temperature
|
24.000
|
Table 19. Sensor Type : NIC TEMPERATUREThe following table explains about Sensor Type: NIC Temperature
| Sensor Name
|
Reading
|
| Temp Sensor.1
|
51.0C
|
Table 20. Sensor Type : NIC POWERThe following table explains about Sensor Type: NIC Power
| Sensor Name
|
Reading
|
| Power Sensor.2
|
26.0W
|