Integrated Dell Remote Access Controller 9 RACADM CLI Guide

PDF

getsensorinfo

Table 1. Details of getsensorinfoThe following table provides details about the getsensorinfo subcommand:
getsensorinfo
Description Displays the status for system sensors.
NOTE:For the Dell PowerEdge FX2 chassis with the FM120x4 server, the power-related information is not displayed.
Synopsis
  • racadm getsensorinfo
  • racadm getsensorinfo -c
Input -c—Compact output format.
NOTE:Chassis Controller is supported only on PowerEdge FX2, and GPU sensors are displayed only on PowerEdge C4140 servers. Example
racadm getsensorinfo
Sensor Type : POWER
NOTE:For current information of supported properties and their values, see the iDRAC Online Help.
Table 2. racadm getsensorinfo Sensor Type : POWERThe following table explains about racadm getsensorinfo Sensor Type : POWER:
<Sensor Name> <Status> <Type> <Input Power>
PS1 Status Present AC Watts
PS2 Status AC-Lost AC Watts
Sensor Type : TEMPERATURE
Table 3. Sensor Type : TEMPERATUREThe following table explains about Sensor Type : TEMPERATURE:
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board Inlet Temp Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board Exhaust Temp Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Sensor Type : FAN
Table 4. Sensor Type : FANThe following table explains about Sensor Type Sensor Type : FAN:
<Sensor Name> <Status> <Reading> <lc> <uc> <PWM %>
System Board Fan1 RPM Ok 5880 RPM 600 RPM NA 21%
System Board Fan2 RPM Ok 6000 RPM 600 RPM NA 0%
System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0%
System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0%
System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144%
System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152%
Sensor Type : VOLTAGE
Table 5. Sensor Type : VOLTAGEThe following table explains about Sensor Type : VOLTAGE :
<Sensor Name> <Status> <Reading> <lc> <uc>
CPU1 VCORE PG Ok Good NA NA
System Board 3.3V PG Ok Good NA NA
System Board 5V AUX PG Ok Good NA NA
CPU1 M23 VPP PG Ok Good NA NA
System Board 1.05V PG Ok Good NA NA
CPU1 M23 VDDQ PG Ok Good NA NA
CPU1 M23 VTT PG Ok Good NA NA
System Board 5V SWITCH PG Ok Good NA NA
System Board VCCIO PG Ok Good NA NA
System Board 2.5V AUX PG Ok Good NA NA
PS1 Voltage 1 Ok -28.00V NA NA
PS1 Voltage 2 Ok 0.00V NA NA
CPU1 M01 VDDQ PG Ok Good NA NA
System Board NDC PG Ok Good NA NA
CPU1 M01 VPP PG Ok Good NA NA
System Board 1.5V PG Ok Good NA NA
System Board PS2 PG Fail Ok Good NA NA
System Board PS1 PG Fail Ok Good NA NA
System Board 1.5V AUX PG Ok Good NA NA
CPU1 M01 VTT PG Ok Good NA NA
PS1 Voltage 1 Ok 240 V NA NA
System Board DIMM PG Ok Good NA NA
Sensor Type : CURRENT
Table 6. Sensor Type : CURRENTThe following table explains about Sensor Type : CURRENT:
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc> [R/W] <unc> [R/W]
PS1 Current 1 Ok 0.4 Amps NA NA 0 Amps [N] 0 Amps [N]
System Board Pwr Consumption Ok 56 Watts NA 1386 Watts 0 Watts [N] 1260 Watts [N]
Sensor Type : PROCESSOR
Table 7. Sensor Type : PROCESSORThe following table explains about Sensor Type : PROCESSOR:
<Sensor Name> <Status> <State> <lc> <uc>
CPU1 Status Ok Presence Detected NA NA
CPU2 Status N/A Absent NA NA
Sensor Type : MEMORY
Table 8. Sensor Type : MEMORYThe following table explains about Sensor Type : MEMORY :
<Sensor Name> <Status> <State> <lc> <uc>
DIMM A1 N/A Presence Detected NA NA
DIMM A2 N/A Absent NA NA
DIMM A3 Ok Absent NA NA
DIMM A4 N/A Absent NA NA
DIMM A5 N/A Absent NA NA
DIMM A6 N/A Absent NA NA
DIMM A7 N/A Absent NA NA
DIMM A8 N/A Absent NA NA
DIMM A9 N/A Absent NA NA
DIMM A10 N/A Absent NA NA
DIMM A11 N/A Absent NA NA
DIMM A12 N/A Absent NA NA
DIMM B1 N/A Absent NA NA
DIMM B2 N/A Absent NA NA
DIMM B3 N/A Absent NA NA
DIMM B4 N/A Absent NA NA
DIMM B5 N/A Absent NA NA
DIMM B6 N/A Absent NA NA
DIMM B7 N/A Absent NA NA
DIMM B8 N/A Absent NA NA
DIMM B9 N/A Absent NA NA
DIMM B10 N/A Absent NA NA
DIMM B11 N/A Absent NA NA
DIMM B12 N/A Absent NA NA
Sensor Type : Chassis Controller
Table 9. Sensor Type : Chassis ControllerThe following table explains about Sensor Type : Chassis Controller :
<Sensor Name> <Status> <State>
Chassis Controller OK OK
Sensor Type : BATTERY
Table 10. Sensor Type : BATTERYThe following table explains about Sensor Type : BATTERY :
<Sensor Name> <Status> <Reading> <lc> <uc>
System Board CMOS Battery Ok Present NA NA
PERC1 ROMB Battery Ok Unknown NA NA
PERC2 ROMB Battery Ok Unknown NA NA
Sensor Type : PERFORMANCE
Table 11. Sensor Type : PERFORMANCEThe following table explains about Sensor Type : PERFORMANCE :
<Sensor Name> <Status> <Status> <lc> <uc>
System Board Power Optimized Ok Not Degraded NA NA
Sensor Type : INTRUSION
Table 12. Sensor Type : INTRUSIONThe following table explains about Sensor Type : INTRUSION :
<Sensor Name> <Intrusion> <Status>
System Board Intrusion Closed Power ON
Sensor Type : REDUNDANCY
Table 13. Sensor Type : REDUNDANCYThe following table explains about Sensor Type : REDUNDANCY :
<Sensor Name> <Status> <Type>
System Board Fan Redundancy Full Redundant Fan
System Board PS Redundancy Disabled PSU
Sensor Type : SYSTEM PERFORMANCE
Table 14. Sensor Type : SYSTEM PERFORMANCEThe following table explains about Sensor Type : SYSTEM PERFORMANCE :
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc> [R/W] <unc> [R/W]
System Board CPU Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board IO Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board MEM Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board SYS Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
Table 15. Sensor Type : GPU PowerThe following table explains about Sensor Type : GPU Power :
<Sensor Name> <PwrConsumption> <PwrSupplyStatus> <BoardPwrSupplyStatus>
Video.Slot.1 4.3MW Enabled Disabled
Video.Slot.3 4.3MW Enabled Disabled
Video.Slot.5 4.3MW Enabled Disabled
Video.Slot.4 4.3MW Enabled Disabled
Video.Slot.8 4.3MW Enabled Disabled
Table 16. Sensor Type : GPU TemperatureThe following table explains about Sensor Type : GPU Temperature :
<Sensor Name> <GPU Temperature> <SecondaryGPUTemp> <BoardTemp> <MemoryTemp>
Video.Slot.1 29C 255C 255C 255C
Video.Slot.3 56C 255C 255C 255C
Video.Slot.5 57C 255C 255C 255C
Video.Slot.4 32C 255C 255C 255C
Video.Slot.8 30C 255C 255C 255C
Table 17. Sensor Type : GPU ThermalThe following table explains about Sensor Type : GPU Thermal :
<Sensor Name> <GPU Target Temp> <MinGPUHwSlowdownTemp> <GPUShutdownTemp> <MaxMemoryOperatingTemp> <MaxGPUOperatingTemp> <ThermalAlertStatus> <PowerBrakeStatus>
Video.Slot.1 255C 255C 255C 255C 255C Disabled Disabled
Video.Slot.3 255C 255C 255C 255C 255C Disabled Disabled
Video.Slot.5 255C 255C 255C 255C 255C Disabled Disabled
Video.Slot.4 255C 255C 255C 255C 255C Disabled Disabled
Video.Slot.8 255C 255C 255C 255C 255C Disabled Disabled
Table 18. Sensor Type : MAX DIMM TEMPERATUREThe following table explains about Sensor Type: MAX DIMM Temperature
Sensor Name Reading
Max DIMM Temperature 24.000
Table 19. Sensor Type : NIC TEMPERATUREThe following table explains about Sensor Type: NIC Temperature
Sensor Name Reading
Temp Sensor.1 51.0C
Table 20. Sensor Type : NIC POWERThe following table explains about Sensor Type: NIC Power
Sensor Name Reading
Power Sensor.2 26.0W