Integrated Dell Remote Access Controller 9 RACADM CLI Guide

PDF

racadm proxy

Table 1. Details of RACADM ProxyThe following table provides details about the RACADM Proxy subcommand:
RACADM Proxy
Description On the PowerEdge FX2/FX2s systems, you can manage the compute sleds and CMC using the iDRAC’s RACADM Proxy feature that redirects commands from iDRAC to CMC. You can return the CMC response to local or remote RACADM.to access the CMC configuration and reporting features without placing the CMC on the management network. The CMC configuration commands are supported through local proxy when local configuration is enabled on iDRAC.
NOTE:Local racadm and local racadm proxy runs with root user privilege.
Synopsis Local RACADM proxy usage
racadm <CMC racadm subcommand> --proxy
Remote RACADM proxy usage
racadm <CMC racadm subcommand> -u <username> -p <password> -r <idrac-ip connected to cmc> --proxy
NOTE:
  • The attribute racadm get -g cfgractuning -o cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC.
  • The attribute racadm get system.ChassisControl.ChassisManagementMonitoring attribute must be enabled in iDRAC.
  • --proxy must be entered at the end of the command.
  • The root privilege is the default privilege for Local RACADM proxy.
  • The user privilege in the Remote RACADM proxy for CMC maps to iDRAC privilege.
    Table 2. Details of CMC and iDRAC privilege for an operationThe following table provides the details of CMC and iDRAC privilege for an operation.
    Required CMC Privilege for an operation Required iDRAC Privilege for proxy operation
    CMC Login User Login
    Chassis Configuration Administrator Configure
    User Configuration Administrator Configure User
    Clear Logs Administrator Logs
    Chassis Control Administrator System Control
    Server Administrator System Control
    Test Alert User System Operations
    Debug Command Administrator Debug
    Fabric x Administrator (where x is A, B, or C) System Control
  • When CMC is not placed on the network, the import, export, and file operation commands to CIFS, NFS, or FTP will fail.
  • When the Remote or Local RACADM Proxy operation is in progress, if the iDRAC is reset, then the Proxy operation fails and the output is not displayed in Remote or Local RACADM.
  • When racadm getsystem.ChassisControl.ChassisManagementMonitoring attribute is set to monitor, all the users including root users can only view the attribute. To configure, set the attribute to monitor and manage in CMC.
Input
  • -u — Specifies the user name of the remote share that stores the catalog file. 
  • -p — Specifies the password of the remote share that stores the catalog file.
  • -r — Specifies the iDRAC IP address connected to CMC.
Example Local RACADM
racadm getractime --proxy
Remote RACADM
racadm getractime -u root -p xxx -r 192.168.0 getractime --proxy