Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series
Technical specifications of PERC 11 cards
The following table lists the specifications of PERC 11 cards:
| Feature | PERC H755 adapter | PERC H755 front SAS | PERC H755N front NVMe | PERC H755 MX adapter | PERC H750 adapter SAS |
|---|---|---|---|---|---|
| RAID levels | 0, 1, 5, 6, 10, 50, 60 | 0, 1, 5, 6, 10, 50, 60 | 0, 1, 5, 6, 10, 50, 60 | 0, 1, 5, 6, 10, 50 ,60 | 0, 1, 5, 6, 10, 50 ,60 |
| Non–RAID | Yes | Yes | Yes | Yes | Yes |
| Enclosures per port | Not applicable | Not applicable | Not applicable | Not applicable | Not applicable |
| Processor | Broadcom RAID-on-chip, SAS3916 chipset | Broadcom RAID-on-chip, SAS3916 chipset | Broadcom RAID-on-chip, SAS3916 chipset | Broadcom RAID-on-chip, SAS3916 chipset | Broadcom RAID-on-chip, SAS3916 chipset |
| Battery backup unit | Yes | Yes | Yes | Yes | Yes |
| Local Key Management security | Yes | Yes | Yes | Yes | Yes |
| Controller queue depth | 5120 | 5120 | 5120 | 5120 | 5120 |
| Secure enterprise key manager security | Yes | Yes | Yes | No | Yes |
| Non-volatile cache | Yes | Yes | Yes | Yes | Yes |
| Cache memory | 8 GB DDR4 2666 MT/s cache | 8 GB DDR4 2666 MT/s cache | 8 GB DDR4 2666 MT/s cache | 8 GB DDR4 2666 MT/s cache | 8 GB DDR4 2666 MT/s cache |
| Cache function | Write back, write through, no read ahead, and read ahead | Write back, write through, no read ahead, and read ahead | Write back, write through, no read ahead, and read ahead | Write back, write through, no read ahead, and read ahead | Write back, write through, no read ahead, and read ahead |
| Max no of VDs in RAID mode | 240 | 240 | 240 | 240 | 240 |
| Max no of disk groups | 240 | 240 | 240 | 240 | 240 |
| Max no of VDs per disk group | 16 | 16 | 16 | 16 | 16 |
| Hot swap devices supported | Yes | Yes | Yes | Yes | Yes |
| Autoconfig | Yes | Yes | Yes | Yes | Yes |
| Hardware XOR engine | Yes | Yes | Yes | Yes | Yes |
| Online capacity expansion | Yes | Yes | Yes | Yes | Yes |
| Dedicated and global hot spare | Yes | Yes | Yes | Yes | Yes |
| Drives types | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s), and Gen4 (16 GT/s) NVMe | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS | Gen3 (8 GT/s) and Gen4 (16 GT/s) NVMe | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s), and Gen4 (16 GT/s) NVMe | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS |
| VD strip size | 64 KB, 128 KB, 256 KB, 512 KB, 1 MB | 64 KB, 128 KB, 256 KB, 512 KB, 1 MB | 64 KB, 128 KB, 256 KB, 512 KB, 1 MB | 64 KB, 128 KB, 256 KB, 512 KB, and 1 MB | 64 KB, 128 KB, 256 KB, 512 KB, 1 MB |
| PCIe support | Gen 4 | Gen 4 | Gen 4 | Gen 4 | Gen 4 |
| SAS/SATA maximum drive support |
|
|
Not applicable | Limited by platform: 8 drives per controller |
|
| NVMe maximum drive support |
|
Not applicable |
|
Limited by platform:8 drives per controller | Not applicable |
NOTE:PERC H755 adapter and PERC H755 MX supports either SAS, SATA, or NVMe drives depending on the backplane/server configuration.
NOTE:PERC controller supports only conventional magnetic recording (CMR) drives, and does not support shingled magnetic recording (SMR) drives.
NOTE:PERC H755 family of controllers currently support SEKM starting with firmware version 52.14.0-3901.
NOTE:For information about the number of drives in a disk group per virtual disk, see
Summary of RAID levels
NOTE:As 14G PowerEdge Servers do not support Gen 4 speeds,
PERC H750 adapter SAS will downtrain to Gen 3 speeds.
| Feature | PERC H355 adapter SAS | PERC H355 front SAS | PERC H350 adapter SAS | PERC H350 Mini Monolithic SAS |
|---|---|---|---|---|
| RAID levels | 0, 1, 10 | 0, 1, 10 | 0, 1, 10 | 0, 1, 10 |
| Non–RAID | Yes | Yes | Yes | Yes |
| Enclosures per port | Not applicable | Not applicable | Not applicable | Not applicable |
| Processor | Broadcom RAID-onchip, SAS3816 chipset | Broadcom RAID-onchip, SAS3816 chipset | Broadcom RAID-onchip, SAS3816 chipset | Broadcom RAID-onchip, SAS3816 chipset |
| Battery backup unit | No | No | No | No |
| Local Key Management security | No | No | No | No |
| Controller queue depth | 1536 | 1536 | 1536 | 1536 |
| Secure enterprise key manager security | No | No | No | No |
| Non-volatile cache | No | No | No | No |
| Cache memory | Not applicable | Not applicable | Not applicable | Not applicable |
| Cache function | Write through, no read ahead | Write through, no read ahead | write through, no read ahead | write through, no read ahead |
| Max no of VDs in RAID mode | 32 | 32 | 32 | 32 |
| Max no of disk groups | 32 | 32 | 32 | 32 |
| Max no of VDs per disk group | 16 | 16 | 16 | 16 |
| Hot swap devices supported | Yes | Yes | Yes | Yes |
| Autoconfig | Yes | Yes | Yes | Yes |
| Hardware XOR engine | Yes | Yes | Yes | Yes |
| Online capacity expansion | Yes | Yes | Yes | Yes |
| Dedicated and global hot spare | Yes | Yes | Yes | Yes |
| Drives types | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s) | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s) | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s) | 3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS, Gen3 (8 GT/s) |
| VD strip size | 64 KB | 64 KB | 64 KB | 64 KB |
| PCIe support | Gen 4 | Gen 4 | Gen 4 | Gen 4 |
| SAS/SATA maximum drive support |
|
|
|
|
| NVMe maximum drive support | Not applicable | Not applicable | Not applicable | Not applicable |
NOTE:As 14G PowerEdge Servers do not support Gen 4 speeds,
PERC H350 adapter SAS and
PERC H350 Mini Monolithic SAS will down train to Gen 3 speeds.