A member disk failure is reported in the virtual disk which undergoes replace member operation
- Issue:
- The source and the target drive which is part of Replace Member operation are online, while a different drive which is a member of the virtual drive reports a failure.
- Probable Cause:
- Physical disk failure or physical disk is removed or disconnected.
- Corrective Action:
- A rebuild starts if there any hot-spares configured or you may replace the failed drive. The Replace Member operation continues as far as the source virtual disk can tolerate the drive failure. If the source virtual disk fails, the Replace Member is stopped, otherwise the virtual disk continues to be in degraded state.