Dell PERC13 and PERC12 User’s Guide PERC H975 Series and PERC H965 Series cards
Source disk fails during replace member operation
- Issue:
- The source disk fails during the Replace Member operation and the Replace Member operation stops due to the source physical disk error.
- Probable Cause:
- Physical disk failure or physical disk is removed or disconnected.
- Corrective Action:
- No action required. If the virtual disk can tolerate disk failure, and the source data is available from other disks in the virtual disk, the rebuild begins automatically on the target disk, using the data from the other disks, if the virtual disk cannot tolerate the failure, the virtual disk goes to offline state and the replace member operation is stopped.