PowerEdge Servers Error and Event Messages Reference Guide

PDF

CPU—Processor Event Messages

CPU0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal error has occurred check for additional logs.
Detailed Description
System event log and OS logs may indicate the source of the error.
Recommended Response Action
Review System Event Log and Operating System Logs. These logs can help the user identify the possible issue that is producing the problem.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
OMSA Event ID
5604
OMSA Trap ID
5604
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 has a thermal trip (over-temperature) event.
Arguments
  • arg1 = number
Detailed Description
The processor temperature increased beyond the operational range. Thermal protection shut down the processor. Factors external to the processor may have induced this exception.
Recommended Response Action
Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heatsink.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> has a thermal trip. Check CPU heat sink
OMSA Event ID
5604
OMSA Trap ID
5604
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 has failed the built-in self-test (BIST).
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is inserted correctly, if the processor is removable. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is stuck in POST.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
1) Turn off the server and disconnect input power for one minute. Re-apply input power and turn system on. 2) Reduce system configuration to minimum memory and remove all PCI devices. If system completes POST, update system BIOS. Re-install memory and PCI one component at a time to meet the original configuration. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 failed to initialize.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is inserted correctly, if the processor is removable. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 configuration is unsupported.
Arguments
  • arg1 = number
Detailed Description
System is unable to boot or may run in a degraded state.
Recommended Response Action
Review product documentation for supported CPU configurations.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> configuration is unsupported. Check CPU or BIOS revision
OMSA Event ID
5604
OMSA Trap ID
5604
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unrecoverable CPU complex error detected on CPU arg1.
Arguments
  • arg1 = number
Detailed Description
System is unable to boot or may run in a degraded state.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is present.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
OMSA Event ID
5602
OMSA Trap ID
5602
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is disabled.
Arguments
  • arg1 = number
Detailed Description
System is unable to boot or may run in a degraded state.
Recommended Response Action
If unexpected, check presence, and system setup (BIOS) configuration.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
OMSA Event ID
5603
OMSA Trap ID
5603
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 terminator is present.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is throttled.
Arguments
  • arg1 = number
Detailed Description
The CPU is throttled due to thermal or power conditions.
Recommended Response Action
Review system logs for power or thermal exceptions.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
CPU <number> is throttled.
OMSA Event ID
5603
OMSA Trap ID
5603
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Uncorrectable Machine Check Exception detected on CPU arg1.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
Review System Event Log and Operating System Logs. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
Uncorrectable Machine Check Exception detected on CPU <number>. Contact Support
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Correctable Machine Check Exception detected on CPU arg1.
Arguments
  • arg1 = number
Detailed Description
A low severity error has occurred and the processor was able to correct the error condition.
Recommended Response Action
No action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
LCD Message
Correctable Machine Check Exception detected on CPU <number>.
OMSA Event ID
5603
OMSA Trap ID
5603
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is operating correctly.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is configured correctly.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 is enabled.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0025

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 terminator is absent.
Arguments
  • arg1 = number
Detailed Description
System is unable to boot or may run in a degraded state.
Recommended Response Action
Check presence and reinstall the terminator.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0700

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 initialization error detected.
Arguments
  • arg1 = number
Detailed Description
System BIOS was unable to boot the processor.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> initialization error detected. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0701

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 protocol error detected.
Arguments
  • arg1 = number
Detailed Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended Response Action
1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> protocol error detected. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0702

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU bus parity error detected.
Detailed Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended Response Action
Check system and operating system logs for exceptions. If no exceptions found, remove input power, reinstall the processor, then apply input power.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU bus parity error detected. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0703

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU bus initialization error detected.
Detailed Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended Response Action
1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU bus initialization error detected. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0704

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 machine check error detected.
Arguments
  • arg1 = number
Detailed Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended Response Action
1) Check system and operating system logs for exceptions. If no exceptions are found, continue to step 2 Otherwise, go to step 3. 2) Update BIOS, if an update is available. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> machine check error detected. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU0800

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module is present.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0801

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module failed.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> voltage regulator module failed. Reseat module
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0802

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A predictive failure detected on CPU arg1 voltage regulator module.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0803

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power input for CPU arg1 voltage regulator module is lost.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
Lost power input for CPU <number> voltage regulator module. Reseat module
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0804

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power input for CPU arg1 voltage regulator module is outside of range.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
Power input for CPU <number> voltage regulator module is outside of range. Reseat module
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0805

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power input for CPU arg1 voltage regulator module is outside of range, but it is attached to the system.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0806

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module is incorrectly configure.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
Review product documentation for proper configuration and installation procedures.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> voltage regulator module incorrectly configure. Check configuration
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0816

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module is absent.
Arguments
  • arg1 = number
Detailed Description
System performance may be degraded or the system may fail to operate.
Recommended Response Action
If removal was unintended, check presence and re-install .
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
CPU <number> voltage regulator module absent. Check module
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0817

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module is operating normally.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0819

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The power input for CPU arg1 voltage regulator module has been restored.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU0822

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU arg1 voltage regulator module is configured correctly.
Arguments
  • arg1 = number
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Trap/EventID
2243
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU4001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Machine Check system address reported by the processor is arg1.
Arguments
  • arg1 = registerReading
Detailed Description
The Machine Check system address reported by the processor is indicated in the message.
Recommended Response Action
This event contains a system address of a component related to a failure reported by the CPU. Map this address to a component in the system to find the source of the error.
Category
System Health (CPU = Processor)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU4002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A processor Machine Check event occurred because the CPU detected an error in an external device (arg1, arg2).
Arguments
  • arg1 = component_name
  • arg2 = register reading
Detailed Description
A processor Machine Check event occurred because the CPU detected an error in an external device as identified in the message.
Recommended Response Action
If the CPU4001 message is reported after CPU4002, map the address reported in CPU4001 to a system component. Update the component driver and firmware. Else, no response action is required.
Category
System Health (CPU = Processor)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU4003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Machine Check event error occurred because the CPU received invalid data (arg1, arg2).
Arguments
  • arg1 = component_name
  • arg2 = register reading
Detailed Description
A Machine Check event error occurred because the CPU received invalid data as identified in the message.
Recommended Response Action
If the CPU4001 message is reported after CPU4003, map the address reported in CPU4001 to a system component. Update the component driver and firmware. Else, no response action is required.
Category
System Health (CPU = Processor)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU4004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Machine Check event error occurred because of a timeout while the CPU accessed an external device or component: (arg1, arg2).
Arguments
  • arg1 = component_name
  • arg2 = register reading
Detailed Description
A Machine Check event error occurred because of a timeout while the CPU accessed an external device or component as identified in the message.
Recommended Response Action
If the CPU4001 message is reported after CPU4004, map the address reported in CPU4001 to a system component. Update the component driver and firmware. Else, no response action is required.
Category
System Health (CPU = Processor)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU4005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Machine Check error was reported by the CPU: (arg1, arg2).
Arguments
  • arg1 = component_name
  • arg2 = register reading
Detailed Description
A Machine Check error was reported by the CPU.
Recommended Response Action
Update the UEFI BIOS. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU5199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown diagnostic event occurred in the High Bandwidth Memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown diagnostic event occurred in the High Bandwidth Memory device at the location identified in the message.
Recommended Response Action
Update iDRAC firmware to the latest version available during the next maintenance cycle. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU6104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the High Bandwidth Memory device at arg1. Perform a cold reboot operation. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the High Bandwidth Memory device at location identified in the message. System will attempt to perform self-healing or self-correction.
Recommended Response Action
Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
Warning event at <location>. Perform a cold reboot operation.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU6114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the High Bandwidth Memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the High Bandwidth Memory device at the location identified in the message.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
Warning event at <location>. Perform a cold reboot operation.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU6199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown diagnostic Warning event occurred in the High Bandwidth Memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown diagnostic Warning event occurred in the High Bandwidth Memory device at the location identified in the message.
Recommended Response Action
Update iDRAC firmware to the latest version available during the next maintenance cycle. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
Unknown warning event at <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU7114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic critical event occurred in the High Bandwidth Memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic critical event occurred in the High Bandwidth Memory device at the location identified in the message.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
Critical event at <location>. Perform a cold reboot operation.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

CPU7199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown diagnostic Critical event occurred in the High Bandwidth Memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown diagnostic Critical event occurred in the High Bandwidth Memory device at the location identified in the message.
Recommended Response Action
Update iDRAC firmware to the latest version available during the next maintenance cycle. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
LCD Message
Unknown critical event at <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU9000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An OEM diagnostic event occurred.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (CPU = Processor)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU9001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
CPU interconnect arg1 has a correctable error.
Arguments
  • arg1 = CPU number
Detailed Description
A correctable error was detected in propagation of signals between processors.
Recommended Response Action
Do the following: 1) Restart the server and verify whether or not the issue persists. 2) If yes, reseat the processors, and then restart the server. 3) If the issue persists, contact your server provider.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
CPU interconnect <CPU number> has a correctable error.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

CPU9002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A link width degradation has occurred in the CPU interconnect arg1.
Arguments
  • arg1 = number
Detailed Description
A link width degradation has occurred in the CPU interconnect identified in the message. The system performance may be degraded or the system may stop operating.
Recommended Response Action
Do the following: 1) Restart the server and verify whether or not the issue persists. 2) If yes, reseat the processors, and then restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Warning
Trap/EventID
2242
LCD Message
CPU interconnect link width has degraded.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU9003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to read the Processor Information ROM (PIROM) data of the CPU arg1 because of communication error.
Arguments
  • arg1 = CPU SlotNum
Detailed Description
The Processor Information ROM (PIROM) data of the CPU identified in themessage cannot be read because of communication error or the CPU is not returning the PIROM data. This condition can cause degradation in the monitoring capability of the system.
Recommended Response Action
Do the following and retry the operation: 1) Power off the server and disconnect the input power. 2) Make sure the CPU is correctly installed if the processor is removable. 3) Connect the input power and power on the server. 4) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

CPU9004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An issue is detected because CPUs are incorrectly installed in the sockets.
Detailed Description
An issue is detected because CPUs are incorrectly installed in the sockets. The system cannot be powered on when the CPUs are not properly populated.
Recommended Response Action
Do the following and retry the operation: 1) Power off the server and disconnect the input power. 2) Make sure the CPU is correctly installed if the processor is removable. 3) Connect the input power and power on the server. 4) If theissue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (CPU = Processor)
Severity
Critical
Trap/EventID
2241
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable